Electronic Overload Relay for Motor TeSys - 20...38 A - 200...240 V AC.
Schneider
SKU
SE_LR97D38M7
Model
LR97D38M7
SGD $119.83
Short description of LR97D38M7
Electronic relays to protect motors up to 38 A (18 kW / 400 V) and related machine components
Country of Origin
Korea
range : TeSys
-  product name : TeSys D
-  device short name : LR97
-  product or component type : Electronic overcurrent relay
-  relay application : Overload Imax > IsettingSensitivity to phase failureLocked rotor, mechanical jamming I > 3 x Isetting
-  product compatibility : LC1D25...D38
-  network type : AC
-  [Us] rated supply voltage : 200...240 V AC
-  thermal protection adjustment range : 20…38 A
-  [Ue] rated operational voltage : 600 V AC 50/60 Hz for power circuit conforming to CSA600 V AC 50/60 Hz for power circuit conforming to UL690 V AC 50/60 Hz for power circuit conforming to IEC 60947-4-1
-  quantity per set : Set of 10
-  product name : TeSys D
-  device short name : LR97
-  product or component type : Electronic overcurrent relay
-  relay application : Overload Imax > IsettingSensitivity to phase failureLocked rotor, mechanical jamming I > 3 x Isetting
-  product compatibility : LC1D25...D38
-  network type : AC
-  [Us] rated supply voltage : 200...240 V AC
-  thermal protection adjustment range : 20…38 A
-  [Ue] rated operational voltage : 600 V AC 50/60 Hz for power circuit conforming to CSA600 V AC 50/60 Hz for power circuit conforming to UL690 V AC 50/60 Hz for power circuit conforming to IEC 60947-4-1
-  quantity per set : Set of 10
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 200...240 V AC |
Contacts Type And Composition | 1 C/O |
Discrete Input Number | 1 C/O |
Product Or Component Type | electronic overcurrent relay |
[Ue] Rated Operational Voltage | 600 V AC 50/60 Hz for power circuit conforming to CSA 600 V AC 50/60 Hz for power circuit conforming to UL 690 V AC 50/60 Hz for power circuit conforming to IEC 60947-4-1 |
Device Short Name | LR97 |
Mounting Support | direct on contactor rail |
Network Type | AC |
Range | TeSys |
Range Name | TeSys LR97D |
Relay Application | locked rotor, mechanical jamming I > 3 x Isetting overload Imax > Isetting sensitivity to phase failure |
COMPLEMENTARY | |
Communication Network Type | 600 V AC 50/60 Hz for power circuit conforming to CSA 600 V AC 50/60 Hz for power circuit conforming to UL 690 V AC 50/60 Hz for power circuit conforming to IEC 60947-4-1 |
Product Name | TeSys D |
Compatibility Code | LR97 |
Connections - Terminals | control circuit: cable 1 x 1-25 mm²flexible with cable end control circuit: cable 1 x 1-25 mm²flexible without cable end control circuit: cable 2 x 1-25 mm² control circuit: cable 2 x 1-25 mm²flexible without cable end control circuit: lug-clamp 1 x 1-25 mm²flexible with cable end control circuit: lug-clamp 1 x 1-25 mm²flexible without cable end control circuit: lug-clamp 2 x 1-25 mm²flexible with cable end control circuit: lug-clamp 2 x 1-25 mm²flexible without cable end power circuit: cable 1 x 1-6 mm²flexible without cable end power circuit: cable 1 x 2.5-10 mm²flexible with cable end power circuit: lug-clamp 1 x 1-6 mm²flexible without cable end power circuit: lug-clamp 1 x 2.5-10 mm²flexible with cable end |
Depth | 67.5 mm |
Height | 67.5 mm |
Maximum Power | 140 VA at 48 V AC conforming to IEC 60947 28 W at 110 V DC conforming to IEC 60947 28 W at 220 V DC conforming to IEC 60947 360 VA at 110 V AC conforming to IEC 60947 360 VA at 220 V AC conforming to IEC 60947 55 W at 24 V DC conforming to IEC 60947 55 W at 48 V DC conforming to IEC 60947 70 VA at 24 V AC conforming to IEC 60947 |
Net Weight | 0.172 kg |
Network Frequency | 50...60 Hz |
Phase Failure Sensitivity | < 3 s |
Product Compatibility | LC1D25...D38 |
Protection Type | BS fuse 3 A - for control circuit GB2 circuit breaker 3 A - for control circuit gG fuse 3 A - for control circuit |
Quantity Per Set | set of 10 |
Reset | automatic reset 120 s fixed electrical by interruption of power supply for minimum 0.1 s manual reset |
Signalling Function | 2 LEDs |
Surge Withstand | 6 kV conforming to IEC 61000-4-5 |
Thermal Protection Adjustment Range | 20-38 A |
Tightening Torque | control circuit: 0.6...1.2 N.m on lug-clamp power circuit: 2 N.m on cable |
Time Range | 0.2...10 s - O-time knob 0.3...10 s - O-time knob 0.5..30 s - D-time knob |
Tripping Threshold | 20...34 A |
Width | 45 mm |
[Ith] Conventional Free Air Thermal Current | 3 A for control circuit |
[Uimp] Rated Impulse Withstand Voltage | 6 kV |
[Ui] Rated Insulation Voltage | power circuit: 600 V conforming to CSA power circuit: 600 V conforming to UL power circuit: 690 V conforming to IEC 60947-4-1 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-60 °C conforming to IEC 60947-4-1 |
Ambient Air Temperature For Storage | -30-80 °C |
Dielectric Strength | 2 V 50 Hz conforming to IEC 60255-5 |
Disturbance Radiated/conducted | 10 V conforming to EN 61000-4-6 class A conforming to EN 55011 |
Fire Resistance | 850 °C conforming to IEC 60695-2-1 |
IP Degree Of Protection | IP20 conforming to IEC 60529 |
Operating Altitude | 2000 m |
Product Certifications | CSA GOST UL |
Protective Treatment | TH conforming to IEC 60068 |
Resistance To Electrostatic Discharge | 6 kV in indirect mode 8 kV in air |
Resistance To Fast Transients | 2 kV |
Resistance To Radiated Fields | 10 V/m level 3 |
Shock Resistance | 15 gn 11 ms conforming to IEC 60068-2-7 |
Standards | IEC 60255-6 IEC 60947 |
Vibration Resistance | 4 gn conforming to IEC 60068-2-6 |
OTHER | |
Poles Description | electronic overcurrent relay |
[Us] Rated Supply Voltage | 200...240 V AC |
Write Your Own Review