TeSys D Contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 24 V DC Standard Coil.

Schneider
SKU
SE_LC1D1156BD
Model
LC1D1156BD
SGD $593.72

Short description of LC1D1156BD

Contactors to control motors up to 150 A (75 kW / 400 V)
Country of Origin
Czechia
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 13 To 15 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
range : TeSys
-  product name : TeSys D
-  product or component type : Contactor
-  device short name : LC1D
-  contactor application : Motor controlResistive load
-  utilisation category : AC
- 3AC
- 1AC
- 4
-  poles description : 3P
-  power pole contact composition : 3 NO
-  [Ue] rated operational voltage : Power circuit-  [Ie] rated operational current : 200 A (at - motor power kW : 30 kW at 220...230 V AC 50/60 Hz (AC
- 3)55 kW at 380...400 V AC 50/60 Hz (AC
- 3)59 kW at 415...440 V AC 50/60 Hz (AC
- 3)75 kW at 500 V AC 50/60 Hz (AC
- 3)80 kW at 660...690 V AC 50/60 Hz (AC
- 3)65 kW at 1000 V AC 50/60 Hz (AC
- 3)18.5 kW at 400 V AC 50/60 Hz (AC
- 4)
-  motor power HP (UL / CSA) : 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors40 hp at 230/240 V AC 50/60 Hz for 3 phases motors75 hp at 460/480 V AC 50/60 Hz for 3 phases motors100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
-  control circuit type : DC standard
-  [Uc] control circuit voltage : 24 V DC
-  auxiliary contact composition : 1 NO + 1 NC
-  [Uimp] rated impulse withstand voltage : 8 kV conforming to IEC 60947
-  overvoltage category : III
-  [Ith] conventional free air thermal current : 200 A (at 60 °C) for power circuit
-  Irms rated making capacity : 1260 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1
-  rated breaking capacity : 1100 A at 440 V for power circuit conforming to IEC 60947
-  [Icw] rated short
- time withstand current : 250 A 40 °C
-  10 min for power circuit550 A 40 °C
-  1 min for power circuit950 A 40 °C
-  10 s for power circuit1100 A 40 °C
-  1 s for power circuit100 A
-  1 s for signalling circuit120 A
-  500 ms for signalling circuit140 A
-  100 ms for signalling circuit
-  associated fuse rating : 250 A gG at - average impedance : 0.6 mOhm
-  Ith 200 A 50 Hz for power circuit
-  [Ui] rated insulation voltage : Power circuit :  600 V CSA certifiedPower circuit :  600 V UL certifiedPower circuit :  1000 V conforming to IEC 60947-4-1Signalling circuit :  690 V conforming to IEC 60947-1Signalling circuit :  600 V CSA certifiedSignalling circuit :  600 V UL certified
-  electrical durability : 0.8 Mcycles 200 A AC
- 1 at Ue
-  power dissipation per pole : 24 W AC
- 17.9 W AC
- 3
-  Front cover : With
-  mounting support : RailPlate
-  standards : CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
-  product certifications : GOSTCCCRINACSAULBVGLLROS (Lloyds register of shipping)DNVUKCA
-  connections
-  terminals : Control circuit :  lugs
- ring terminals (external diameter :  8 mm) Power circuit :  lugs
- ring terminals (external diameter :  25 mm) Power circuit :  bars 1 cable(s)
-  busbar cross section :  5 x 25 mm
-  tightening torque : Control circuit :  1.2 N.m
-  on lugs
- ring terminals
-  with screwdriver flat Ø 6 mm M3.5Control circuit :  1.2 N.m
-  on lugs
- ring terminals
-  with screwdriver Philips No 2 M3.5Power circuit :  12 N.m
-  on lugs
- ring terminals hexagonal screw head 13 mm M8Power circuit :  12 N.m
-  on bars hexagonal screw head 13 mm M8
-  operating time : 20...35 ms closing40...75 ms opening
-  safety reliability level : B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
-  mechanical durability : 8 Mcycles
-  maximum operating rate : 1200 cyc/h 60 °C
MAIN SPECIFICATIONS
Control Type3P
Product Or Component Typecontactor
Range Of ProductTeSys D
[Ie] Rated Operational Current115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] Control Circuit Voltage24 V DC
[Ue] Rated Operational Voltagepower circuit: <= 1000 V AC 25...400 Hz
power circuit: <= 300 V DC
Average Impedance0.6 mOhm - Ith 200 A 50 Hz for power circuit
Contactor Applicationmotor control
resistive load
Control Circuit TypeDC standard
Device Short NameLC1D
Motor Power Hp100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
40 hp at 230/240 V AC 50/60 Hz for 3 phases motors
75 hp at 460/480 V AC 50/60 Hz for 3 phases motors
Mounting Supportplate
rail
Pole Contact Composition3 NO
Power Dissipation Per Pole24 W AC-1
7.9 W AC-3
Protective Coverwith
RangeTeSys
Range NameTeSys D
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Utilisation CategoryAC-1
AC-3
AC-4
COMPLEMENTARY
Communication Network Typepower circuit: <= 1000 V AC 25...400 Hz
power circuit: <= 300 V DC
Product NameTeSys D
Associated Fuse Rating10 A gG for signalling circuit
200 A gG at <= 690 V coordination type 2 for power circuit
250 A gG at <= 690 V coordination type 1 for power circuit
Auxiliary Contact Composition1 NO + 1 NC
Auxiliary Contacts Type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Coil Technologywith integral suppression device
Compatibility CodeLC1D
Connections - Terminalscontrol circuit: lugs-ring terminals (external diameter: 8 mm)
power circuit: bars 1 cable(s) - busbar cross section: 5 x 25 mm
power circuit: lugs-ring terminals (external diameter: 25 mm)
Contact CompatibilityM10
Control Circuit Voltage Limits0.15...0.4 Uc (-40-70 °C):drop-out DC
0.75...1.2 Uc (-40-55 °C):operational DC
1...1.2 Uc (55-70 °C):operational DC
Depth136 mm
Electrical Durability0.8 Mcycles 200 A AC-1 at Ue <= 440 V
0.95 Mcycles 115 A AC-3 at Ue <= 440 V
Flame RetardanceV1 conforming to UL 94
Height158 mm
Hold-in Power Consumption In W2.4-5.1 W at 20 °C
Inrush Power In W270-365 W (at 20 °C)
Insulation Resistance> 10 MOhm for signalling circuit
Irms Rated Making Capacity1260 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Maximum Operating Rate1200 cyc/h 60 °C
Mechanical Durability8 Mcycles
Mechanical Robustnessshocks contactor closed: 15 Gn for 11 ms
shocks contactor open: 6 Gn for 11 ms
vibrations contactor closed: 4 Gn, 5...300 Hz
vibrations contactor open: 2 Gn, 5...300 Hz
Minimum Switching Current5 mA for signalling circuit
Minimum Switching Voltage17 V for signalling circuit
Motor Power KW18.5 kW at 400 V AC 50/60 Hz (AC-4)
30 kW at 220...230 V AC 50/60 Hz (AC-3)
55 kW at 380...400 V AC 50/60 Hz (AC-3)
59 kW at 415...440 V AC 50/60 Hz (AC-3)
65 kW at 1000 V AC 50/60 Hz (AC-3)
75 kW at 500 V AC 50/60 Hz (AC-3)
80 kW at 660...690 V AC 50/60 Hz (AC-3)
Net Weight2.5 kg
Non-overlap Time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Operating Time20...35 ms closing
40...75 ms opening
Rated Breaking Capacity1100 A at 440 V for power circuit conforming to IEC 60947
Signalling Circuit Frequency25...400 Hz
Tightening Torquecontrol circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
Time Constant25 ms
Width120 mm
[Icw] Rated Short-time Withstand Current100 A - 1 s for signalling circuit
1100 A 40 °C - 1 s for power circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
250 A 40 °C - 10 min for power circuit
550 A 40 °C - 1 min for power circuit
950 A 40 °C - 10 s for power circuit
[Ith] Conventional Free Air Thermal Current200 A (at 60 °C) for power circuit
[Uimp] Rated Impulse Withstand Voltage8 kV conforming to IEC 60947
[Ui] Rated Insulation Voltagepower circuit: 1000 V conforming to IEC 60947-4-1
power circuit: 600 V CSA certified
power circuit: 600 V UL certified
signalling circuit: 600 V CSA certified
signalling circuit: 600 V UL certified
signalling circuit: 690 V conforming to IEC 60947-1
ENVIRONMENT
Ambient Air Temperature For Operation-40-60 °C
60-70 °C with derating
Ambient Air Temperature For Storage-60-80 °C
Fire Resistance850 °C conforming to IEC 60695-2-1
IP Degree Of ProtectionIP20 front face conforming to IEC 60529
Operating Altitude0...3000 m
Overvoltage CategoryIII
Pollution Degree3
Product CertificationsBV
CCC
CSA
DNV
GL
GOST
LROS (Lloyds register of shipping)
RINA
UKCA
UL
Protective TreatmentTH conforming to IEC 60068-2-30
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
OTHER
Poles Description3P
[Us] Rated Supply VoltageTeSys D
Write Your Own Review
You're reviewing:TeSys D Contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 24 V DC Standard Coil.
Your Rating