TeSys D Contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 24 V DC Standard Coil.
Schneider
SKU
SE_LC1D1156BD
Model
LC1D1156BD
SGD $593.72
Short description of LC1D1156BD
Contactors to control motors up to 150 A (75 kW / 400 V)
Country of Origin
Czechia
range : TeSys
-  product name : TeSys D
-  product or component type : Contactor
-  device short name : LC1D
-  contactor application : Motor controlResistive load
-  utilisation category : AC
- 3AC
- 1AC
- 4
-  poles description : 3P
-  power pole contact composition : 3 NO
-  [Ue] rated operational voltage : Power circuit-  [Ie] rated operational current : 200 A (at - motor power kW : 30 kW at 220...230 V AC 50/60 Hz (AC
- 3)55 kW at 380...400 V AC 50/60 Hz (AC
- 3)59 kW at 415...440 V AC 50/60 Hz (AC
- 3)75 kW at 500 V AC 50/60 Hz (AC
- 3)80 kW at 660...690 V AC 50/60 Hz (AC
- 3)65 kW at 1000 V AC 50/60 Hz (AC
- 3)18.5 kW at 400 V AC 50/60 Hz (AC
- 4)
-  motor power HP (UL / CSA) : 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors40 hp at 230/240 V AC 50/60 Hz for 3 phases motors75 hp at 460/480 V AC 50/60 Hz for 3 phases motors100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
-  control circuit type : DC standard
-  [Uc] control circuit voltage : 24 V DC
-  auxiliary contact composition : 1 NO + 1 NC
-  [Uimp] rated impulse withstand voltage : 8 kV conforming to IEC 60947
-  overvoltage category : III
-  [Ith] conventional free air thermal current : 200 A (at 60 °C) for power circuit
-  Irms rated making capacity : 1260 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1
-  rated breaking capacity : 1100 A at 440 V for power circuit conforming to IEC 60947
-  [Icw] rated short
- time withstand current : 250 A 40 °C
-  10 min for power circuit550 A 40 °C
-  1 min for power circuit950 A 40 °C
-  10 s for power circuit1100 A 40 °C
-  1 s for power circuit100 A
-  1 s for signalling circuit120 A
-  500 ms for signalling circuit140 A
-  100 ms for signalling circuit
-  associated fuse rating : 250 A gG at - average impedance : 0.6 mOhm
-  Ith 200 A 50 Hz for power circuit
-  [Ui] rated insulation voltage : Power circuit :  600 V CSA certifiedPower circuit :  600 V UL certifiedPower circuit :  1000 V conforming to IEC 60947-4-1Signalling circuit :  690 V conforming to IEC 60947-1Signalling circuit :  600 V CSA certifiedSignalling circuit :  600 V UL certified
-  electrical durability : 0.8 Mcycles 200 A AC
- 1 at Ue
-  power dissipation per pole : 24 W AC
- 17.9 W AC
- 3
-  Front cover : With
-  mounting support : RailPlate
-  standards : CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
-  product certifications : GOSTCCCRINACSAULBVGLLROS (Lloyds register of shipping)DNVUKCA
-  connections
-  terminals : Control circuit :  lugs
- ring terminals (external diameter :  8 mm) Power circuit :  lugs
- ring terminals (external diameter :  25 mm) Power circuit :  bars 1 cable(s)
-  busbar cross section :  5 x 25 mm
-  tightening torque : Control circuit :  1.2 N.m
-  on lugs
- ring terminals
-  with screwdriver flat Ø 6 mm M3.5Control circuit :  1.2 N.m
-  on lugs
- ring terminals
-  with screwdriver Philips No 2 M3.5Power circuit :  12 N.m
-  on lugs
- ring terminals hexagonal screw head 13 mm M8Power circuit :  12 N.m
-  on bars hexagonal screw head 13 mm M8
-  operating time : 20...35 ms closing40...75 ms opening
-  safety reliability level : B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
-  mechanical durability : 8 Mcycles
-  maximum operating rate : 1200 cyc/h 60 °C
-  product name : TeSys D
-  product or component type : Contactor
-  device short name : LC1D
-  contactor application : Motor controlResistive load
-  utilisation category : AC
- 3AC
- 1AC
- 4
-  poles description : 3P
-  power pole contact composition : 3 NO
-  [Ue] rated operational voltage : Power circuit-  [Ie] rated operational current : 200 A (at - motor power kW : 30 kW at 220...230 V AC 50/60 Hz (AC
- 3)55 kW at 380...400 V AC 50/60 Hz (AC
- 3)59 kW at 415...440 V AC 50/60 Hz (AC
- 3)75 kW at 500 V AC 50/60 Hz (AC
- 3)80 kW at 660...690 V AC 50/60 Hz (AC
- 3)65 kW at 1000 V AC 50/60 Hz (AC
- 3)18.5 kW at 400 V AC 50/60 Hz (AC
- 4)
-  motor power HP (UL / CSA) : 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors40 hp at 230/240 V AC 50/60 Hz for 3 phases motors75 hp at 460/480 V AC 50/60 Hz for 3 phases motors100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
-  control circuit type : DC standard
-  [Uc] control circuit voltage : 24 V DC
-  auxiliary contact composition : 1 NO + 1 NC
-  [Uimp] rated impulse withstand voltage : 8 kV conforming to IEC 60947
-  overvoltage category : III
-  [Ith] conventional free air thermal current : 200 A (at 60 °C) for power circuit
-  Irms rated making capacity : 1260 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1
-  rated breaking capacity : 1100 A at 440 V for power circuit conforming to IEC 60947
-  [Icw] rated short
- time withstand current : 250 A 40 °C
-  10 min for power circuit550 A 40 °C
-  1 min for power circuit950 A 40 °C
-  10 s for power circuit1100 A 40 °C
-  1 s for power circuit100 A
-  1 s for signalling circuit120 A
-  500 ms for signalling circuit140 A
-  100 ms for signalling circuit
-  associated fuse rating : 250 A gG at - average impedance : 0.6 mOhm
-  Ith 200 A 50 Hz for power circuit
-  [Ui] rated insulation voltage : Power circuit :  600 V CSA certifiedPower circuit :  600 V UL certifiedPower circuit :  1000 V conforming to IEC 60947-4-1Signalling circuit :  690 V conforming to IEC 60947-1Signalling circuit :  600 V CSA certifiedSignalling circuit :  600 V UL certified
-  electrical durability : 0.8 Mcycles 200 A AC
- 1 at Ue
-  power dissipation per pole : 24 W AC
- 17.9 W AC
- 3
-  Front cover : With
-  mounting support : RailPlate
-  standards : CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
-  product certifications : GOSTCCCRINACSAULBVGLLROS (Lloyds register of shipping)DNVUKCA
-  connections
-  terminals : Control circuit :  lugs
- ring terminals (external diameter :  8 mm) Power circuit :  lugs
- ring terminals (external diameter :  25 mm) Power circuit :  bars 1 cable(s)
-  busbar cross section :  5 x 25 mm
-  tightening torque : Control circuit :  1.2 N.m
-  on lugs
- ring terminals
-  with screwdriver flat Ø 6 mm M3.5Control circuit :  1.2 N.m
-  on lugs
- ring terminals
-  with screwdriver Philips No 2 M3.5Power circuit :  12 N.m
-  on lugs
- ring terminals hexagonal screw head 13 mm M8Power circuit :  12 N.m
-  on bars hexagonal screw head 13 mm M8
-  operating time : 20...35 ms closing40...75 ms opening
-  safety reliability level : B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
-  mechanical durability : 8 Mcycles
-  maximum operating rate : 1200 cyc/h 60 °C
MAIN SPECIFICATIONS | |
---|---|
Control Type | 3P |
Product Or Component Type | contactor |
Range Of Product | TeSys D |
[Ie] Rated Operational Current | 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
[Uc] Control Circuit Voltage | 24 V DC |
[Ue] Rated Operational Voltage | power circuit: <= 1000 V AC 25...400 Hz power circuit: <= 300 V DC |
Average Impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit |
Contactor Application | motor control resistive load |
Control Circuit Type | DC standard |
Device Short Name | LC1D |
Motor Power Hp | 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors |
Mounting Support | plate rail |
Pole Contact Composition | 3 NO |
Power Dissipation Per Pole | 24 W AC-1 7.9 W AC-3 |
Protective Cover | with |
Range | TeSys |
Range Name | TeSys D |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Utilisation Category | AC-1 AC-3 AC-4 |
COMPLEMENTARY | |
Communication Network Type | power circuit: <= 1000 V AC 25...400 Hz power circuit: <= 300 V DC |
Product Name | TeSys D |
Associated Fuse Rating | 10 A gG for signalling circuit 200 A gG at <= 690 V coordination type 2 for power circuit 250 A gG at <= 690 V coordination type 1 for power circuit |
Auxiliary Contact Composition | 1 NO + 1 NC |
Auxiliary Contacts Type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
Coil Technology | with integral suppression device |
Compatibility Code | LC1D |
Connections - Terminals | control circuit: lugs-ring terminals (external diameter: 8 mm) power circuit: bars 1 cable(s) - busbar cross section: 5 x 25 mm power circuit: lugs-ring terminals (external diameter: 25 mm) |
Contact Compatibility | M10 |
Control Circuit Voltage Limits | 0.15...0.4 Uc (-40-70 °C):drop-out DC 0.75...1.2 Uc (-40-55 °C):operational DC 1...1.2 Uc (55-70 °C):operational DC |
Depth | 136 mm |
Electrical Durability | 0.8 Mcycles 200 A AC-1 at Ue <= 440 V 0.95 Mcycles 115 A AC-3 at Ue <= 440 V |
Flame Retardance | V1 conforming to UL 94 |
Height | 158 mm |
Hold-in Power Consumption In W | 2.4-5.1 W at 20 °C |
Inrush Power In W | 270-365 W (at 20 °C) |
Insulation Resistance | > 10 MOhm for signalling circuit |
Irms Rated Making Capacity | 1260 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
Maximum Operating Rate | 1200 cyc/h 60 °C |
Mechanical Durability | 8 Mcycles |
Mechanical Robustness | shocks contactor closed: 15 Gn for 11 ms shocks contactor open: 6 Gn for 11 ms vibrations contactor closed: 4 Gn, 5...300 Hz vibrations contactor open: 2 Gn, 5...300 Hz |
Minimum Switching Current | 5 mA for signalling circuit |
Minimum Switching Voltage | 17 V for signalling circuit |
Motor Power KW | 18.5 kW at 400 V AC 50/60 Hz (AC-4) 30 kW at 220...230 V AC 50/60 Hz (AC-3) 55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415...440 V AC 50/60 Hz (AC-3) 65 kW at 1000 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) |
Net Weight | 2.5 kg |
Non-overlap Time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Operating Time | 20...35 ms closing 40...75 ms opening |
Rated Breaking Capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
Signalling Circuit Frequency | 25...400 Hz |
Tightening Torque | control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5 control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5 power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8 power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8 |
Time Constant | 25 ms |
Width | 120 mm |
[Icw] Rated Short-time Withstand Current | 100 A - 1 s for signalling circuit 1100 A 40 °C - 1 s for power circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit 250 A 40 °C - 10 min for power circuit 550 A 40 °C - 1 min for power circuit 950 A 40 °C - 10 s for power circuit |
[Ith] Conventional Free Air Thermal Current | 200 A (at 60 °C) for power circuit |
[Uimp] Rated Impulse Withstand Voltage | 8 kV conforming to IEC 60947 |
[Ui] Rated Insulation Voltage | power circuit: 1000 V conforming to IEC 60947-4-1 power circuit: 600 V CSA certified power circuit: 600 V UL certified signalling circuit: 600 V CSA certified signalling circuit: 600 V UL certified signalling circuit: 690 V conforming to IEC 60947-1 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -40-60 °C 60-70 °C with derating |
Ambient Air Temperature For Storage | -60-80 °C |
Fire Resistance | 850 °C conforming to IEC 60695-2-1 |
IP Degree Of Protection | IP20 front face conforming to IEC 60529 |
Operating Altitude | 0...3000 m |
Overvoltage Category | III |
Pollution Degree | 3 |
Product Certifications | BV CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UKCA UL |
Protective Treatment | TH conforming to IEC 60068-2-30 |
Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
OTHER | |
Poles Description | 3P |
[Us] Rated Supply Voltage | TeSys D |
Write Your Own Review