Motor Circuit Breaker, TeSys GV2, 3P, 20-25 A, Thermal Magnetic, Lugs Terminals
Schneider
SKU
SE_GV2ME226
Model
GV2ME226
SGD $102.53
Short description of GV2ME226
MOTOR CIRCUIT BREAKER MGTH 20 25 LUG T
Country of Origin
Thailand
TeSys GV2
-  Circuit breaker
-  thermal
- magnetic
-  20...25 A
-  lugs
- ring terminals.
Label :  TeSys GV2
-  range of product :  TeSys GV2
-  range :  TeSys
-  trip unit technology :  thermal
- magnetic
-  product name :  TeSys GV2
-  device short name :  GV2ME
-  product or component type :  circuit breaker
-  device application :  motor
-  Range Presentation : 
-  Manual and local control, when the motor circuit-breaker is used on its own, and automatic and remote control when combined with a contactor
-  Motor protection provided by thermal
- magnetic devices built into the circuit-breaker
-  No live parts are accessible to direct finger contact
-  The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost
-  The addition of a shunt trip enables remote control of tripping
-  The control for the open or enclosed motor circuit-breaker can be locked in the “N/C" position using 3 padlocks
-  Connectors :  spring terminal, screw clamp
-  Range Benefits :  Complete protection concentrated in a single productCompact and simple to select, TeSys GV2 motor circuit-breakers are only 45 mm wide and are categorised
according to their level of performance and functions :  type of control, breaking capacity, motor protection and accessories.
-  Range Application Presentation : 
-  Industry, infrastructure, building, etc : 
-  Motor control and protection, in accordance with standards IEC 947-2 and IEC 947-4-1
-  Easily inserted in any configuration by screw or clip-fixing onto mounting rails
-  Circuit breaker
-  thermal
- magnetic
-  20...25 A
-  lugs
- ring terminals.
Label :  TeSys GV2
-  range of product :  TeSys GV2
-  range :  TeSys
-  trip unit technology :  thermal
- magnetic
-  product name :  TeSys GV2
-  device short name :  GV2ME
-  product or component type :  circuit breaker
-  device application :  motor
-  Range Presentation : 
-  Manual and local control, when the motor circuit-breaker is used on its own, and automatic and remote control when combined with a contactor
-  Motor protection provided by thermal
- magnetic devices built into the circuit-breaker
-  No live parts are accessible to direct finger contact
-  The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost
-  The addition of a shunt trip enables remote control of tripping
-  The control for the open or enclosed motor circuit-breaker can be locked in the “N/C" position using 3 padlocks
-  Connectors :  spring terminal, screw clamp
-  Range Benefits :  Complete protection concentrated in a single productCompact and simple to select, TeSys GV2 motor circuit-breakers are only 45 mm wide and are categorised
according to their level of performance and functions :  type of control, breaking capacity, motor protection and accessories.
-  Range Application Presentation : 
-  Industry, infrastructure, building, etc : 
-  Motor control and protection, in accordance with standards IEC 947-2 and IEC 947-4-1
-  Easily inserted in any configuration by screw or clip-fixing onto mounting rails
MAIN SPECIFICATIONS | |
---|---|
Breaking Capacity | 15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
Contacts Type And Composition | 25 A |
Control Type | push-button |
Product Or Component Type | circuit breaker |
Range Of Product | TeSys GV2 |
[Ie] Rated Operational Current | push-button |
[Ue] Rated Operational Voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Device Short Name | GV2ME |
EAN13 | 3389110611496 |
Network Type | AC |
Power Dissipation Per Pole | 2.5 W |
Range | TeSys TeSys Deca |
Range Name | TeSys GV2 |
Suitability For Isolation | yes conforming to IEC 60947-1 |
Trip Unit Technology | thermal-magnetic |
Utilisation Category | AC-3 conforming to IEC 60947-4-1 category A conforming to IEC 60947-2 |
[Ics] Rated Service Short-circuit Breaking Capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 40 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
COMPLEMENTARY | |
Communication Network Type | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Interlocked Device | 15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
Product Name | TeSys Deca TeSys GV2 |
[In] Rated Current | 25 A |
Colour | dark grey |
Compatibility Code | GV2ME |
Connection Pitch | 13.5 mm without spreader |
Depth | 78.5 mm |
Device Application | motor |
Direct Connector | without |
Electrical Durability | 100000 cycles for AC-3 at 440 V |
Fixing Mode | 35 mm symmetrical DIN rail: clipped panel: screwed (with adaptor plate) |
Height | 89 mm |
Magnetic Tripping Current | 327-327 A |
Maximum Operating Rate | 25 cyc/h |
Mechanical Durability | 100000 cycles |
Motor Power KW | 11-11 kW at 400/415 V AC 50/60 Hz 15-15 kW at 500 V AC 50/60 Hz |
Net Weight | 0.26 kg |
Network Frequency | 50/60 Hz conforming to IEC 60947-4-1 |
Operating Position | any position |
Phase Failure Sensitivity | yes conforming to IEC 60947-4-1 |
Rated Duty | continuous conforming to IEC 60947-4-1 |
Tightening Torque | 1.7 N.m on bars M4 screw type 1.7 N.m on lugs-ring terminals M4 screw type |
Trip Unit Rating | 20-25 A |
Width | 45 mm |
[Ith] Conventional Free Air Thermal Current | 25 A conforming to IEC 60947-4-1 |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947-2 |
[Ui] Rated Insulation Voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -20-60 °C |
Ambient Air Temperature For Storage | -40-80 °C |
Fire Resistance | 960 °C conforming to IEC 60695-2-1 |
IK Degree Of Protection | IK04 |
IP Degree Of Protection | IP20 conforming to IEC 60529 |
Operating Altitude | 2000 m |
Product Certifications | ATEX BV CCC CSA DNV-GL EAC IECEE CB Scheme LROS (Lloyds register of shipping) RINA UKCA UL |
Protective Treatment | TH |
Standards | CSA C22.2 No 60947-4-1 EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 |
OTHER | |
Poles Description | 3P |
[Us] Rated Supply Voltage | TeSys GV2 |
Write Your Own Review