TeSys D Control Relay - 3 NO + 2 NC - <= 690 V - 24 V DC Standard Coil.
Schneider
SKU
SE_CAD32BD
Model
CAD32BD
SGD $56.24
Short description of CAD32BD
TeSys D,K and SK Relays for control circuits
Country of Origin
Indonesia
range : TeSys
-  product name : TeSys CAD
-  product or component type : Control relay
-  device short name : CAD
-  contactor application : Control circuit
-  product name : TeSys CAD
-  product or component type : Control relay
-  device short name : CAD
-  contactor application : Control circuit
MAIN SPECIFICATIONS | |
---|---|
Product Or Component Type | control relay |
Range Of Product | TeSys D control relay |
[Uc] Control Circuit Voltage | 24 V DC |
[Ue] Rated Operational Voltage | <= 690 V AC 25...400 Hz |
Contactor Application | control circuit |
Control Circuit Type | DC standard |
Device Short Name | CAD |
Mounting Support | plate rail |
Pole Contact Composition | 3 NO + 2 NC |
Range | TeSys TeSys Deca |
Range Name | TeSys Control Relays |
Utilisation Category | AC-14 AC-15 DC-13 |
COMPLEMENTARY | |
Communication Network Type | <= 690 V AC 25...400 Hz |
Product Name | TeSys CAD |
Associated Fuse Rating | 10 A gG conforming to IEC 60947-5-1 |
Compatibility Code | CAD |
Connections - Terminals | screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end |
Control Circuit Voltage Limits | 0.1...0.25 Uc (-40-70 °C):drop-out DC 0.7...1.25 Uc (-40-60 °C):operational DC 1...1.25 Uc (60-70 °C):operational DC |
Depth | 93 mm |
Height | 77 mm |
Hold-in Power Consumption In W | 5.4-5.4 W at 20 °C |
Inrush Power In W | 5.4-5.4 W (at 20 °C) |
Insulation Resistance | > 10 MOhm |
Irms Rated Making Capacity | 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
Maximum Operating Rate | 180 cyc/mn |
Mechanical Durability | 30 Mcycles |
Mechanical Robustness | shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
Minimum Switching Current | 5 mA |
Minimum Switching Voltage | 17 V |
Net Weight | 0.58 kg |
Non-overlap Time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Operating Time | 15...25 ms coil de-energisation and NC closing 16...24 ms coil de-energisation and NO opening 47...63 ms coil energisation and NC opening 53...72 ms coil energisation and NO closing |
Tightening Torque | 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
Time Constant | 28 ms |
Width | 45 mm |
[Icw] Rated Short-time Withstand Current | 100 A - 1 s 120 A - 500 ms 140 A - 100 ms |
[Ith] Conventional Free Air Thermal Current | 10 A (at 60 °C) |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947 |
[Ui] Rated Insulation Voltage | 600 V CSA certified 600 V UL certified 690 V conforming to IEC 60947-5-1 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -40-60 °C 60-70 °C with derating |
Ambient Air Temperature For Storage | -60-80 °C |
IP Degree Of Protection | IP2x front face conforming to VDE 0106 |
Operating Altitude | 0...3000 m |
Product Certifications | CSA UKCA UL |
Protective Treatment | TH conforming to IEC 60068 |
Standards | BS 4794 EN 60947-5 IEC 60335-1 IEC 60947-5-1 NF C 63-140 VDE 0660 |
OTHER | |
Poles Description | control relay |
[Us] Rated Supply Voltage | TeSys D control relay |