Singapore GST will increase from 8% to 9%

(Effective from Jan 1, 2024)

Electgo: Your trusted Source for Electrical Components in Singapore

An Authorized Supplier Offering a Comprehensive Range of Electrical Component Categories

Loading...

Circuit Breaker ComPacT NSX100N, 50kA At 415VAC, TMD Trip Unit 100A, 3 Poles 3d

Schneider
SKU
SE_C10N3TM100
Model
C10N3TM100
SGD $303.52

Short description of C10N3TM100

NSX100N 50kA AC 3P3D 100A TMD
Country of Origin
India
-
+

UOM: Piece

In stock
In Stock 7
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
MAIN SPECIFICATIONS
Breaking Capacity10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 600 V AC 50/60 Hz conforming to UL 508
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 480 V AC 50/60 Hz conforming to UL 508
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 240 V AC 50/60 Hz conforming to UL 508
90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking Capacity CodeN 50 kA 415 V AC
Contacts Type And Composition100 A at 40 °C
Control Typetoggle
Product Or Component Typecircuit breaker
Range Of ProductComPacT NSX100...250 new generation
Trip Unit NameTM-D
[Ie] Rated Operational Currenttoggle
[Ue] Rated Operational Voltage690 V AC 50/60 Hz
Device Short NameNSX100N
EAN133606481997784
Mounting Supportbackplate
Network TypeAC
Protected Poles Description3t
RangeComPacT new generation
Range NameComPacT NSX (2021)
Suitability For Isolationyes conforming to EN/IEC 60947-2
Trip Unit Protection FunctionsLI
Trip Unit Technologythermal-magnetic
Utilisation Categorycategory A
COMPLEMENTARY
Communication Network Type690 V AC 50/60 Hz
Current Transformer TypeN 50 kA 415 V AC
Interlocked Device10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 600 V AC 50/60 Hz conforming to UL 508
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 480 V AC 50/60 Hz conforming to UL 508
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 240 V AC 50/60 Hz conforming to UL 508
90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Product NameComPacT NSX new generation
[Ics] Rated Service Breaking Capacity10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
[In] Rated Current100 A at 40 °C
Compatibility CodeNSX100
Connection Pitch35 mm
Depth86 mm
Device Applicationdistribution
Downside Connectionfront
Earth-leakage Protectionwithout
Electrical Durability10000 cycles at 690 V In
20000 cycles at 690 V In/2
30000 cycles at 440 V In
50000 cycles at 440 V In/2
Height161 mm
Long Time Delay Adjustment Typefixed
Long Time Pick-up Adjustment Range0.7...1 x In
Long Time Pick-up Adjustment Type Iradjustable
Mechanical Durability50000 cycles
Mounting Modefixed
Net Weight2.05 kg
Network Frequency50/60 Hz
Number Of Slots5 slot(s)
Power Losses8.8 W
Protection TypeI : for short-circuit protection (magnetic)
L : for overload protection (thermal)
Short-time Delay Adjustment Typefixed
Short-time Pick-up Adjustment Type Isdfixed
Trip Unit Rating100-100 A at 40 °C
Upside Connectionfront
Width105 mm
[Isd] Short-time Pick-up Adjustment Range800 A
[tr] Long-time Delay Adjustment Range120-400 s at 1.5 x In
15-15 s at 6 x Ir
[Uimp] Rated Impulse Withstand Voltage8 kV
[Ui] Rated Insulation Voltage800 V AC 50/60 Hz
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-50-85 °C
Electrical Shock Protection Classclass II
IK Degree Of ProtectionIK07 conforming to IEC 62262
IP Degree Of ProtectionIP40 conforming to IEC 60529
Operating Altitude0...2000 m without derating
2000 m...5000 m with derating
Overvoltage Categoryclass II
Pollution Degree3 conforming to IEC 60664-1
Product CertificationsCCC
EAC
Marine
Relative Humidity0-95 %
StandardsEN/IEC 60947
OTHER
Earth Leakage CurrentTM-D
Poles Description3P
[Us] Rated Supply VoltageComPacT NSX100...250 new generation
Write Your Own Review
You're reviewing:Circuit Breaker ComPacT NSX100N, 50kA At 415VAC, TMD Trip Unit 100A, 3 Poles 3d
Your Rating