Circuit Breaker ComPacT NSX100B, 25kA At 415VAC, MicroLogic 4.2 Vigi Trip Unit 100A, 4 Poles 4d

Schneider
SKU
SE_C10B44V100
Model
C10B44V100
SGD $2,229.03

Short description of C10B44V100

NSX100B 25kA AC 4P4D 100A 4.2
Country of Origin
China
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 4 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
MAIN SPECIFICATIONS
Breaking Capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking Capacity CodeB 25 kA 415 V AC
Contacts Type And Composition100 A at 40 °C
Control Typetoggle
Product Or Component Typeearth leakage circuit breaker
Range Of ProductComPacT NSX100...250 new generation
Trip Unit NameMicrologic 4.2
[Ie] Rated Operational Currenttoggle
[Ue] Rated Operational Voltage440 V AC 50/60 Hz
Device Short NameNSX100B
EAN133606481993328
Earth-leakage Protection Classclass A
Mounting Supportbackplate
Network TypeAC
Neutral Positionleft
Protected Poles Description3t
3t + N/2
4t
RangeComPacT new generation
Range NameComPacT NSX (2021)
Suitability For Isolationyes conforming to EN/IEC 60947-2
Trip Unit Protection FunctionsLSoIR
Trip Unit Technologyelectronic
Utilisation Categorycategory A
COMPLEMENTARY
Communication Network Type440 V AC 50/60 Hz
Current Transformer TypeB 25 kA 415 V AC
Interlocked Device20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Product NameComPacT NSX new generation
[Ics] Rated Service Breaking Capacity20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
[In] Rated Current100 A at 40 °C
Compatibility CodeNSX100
Connection Pitch35 mm
Depth86 mm
Device Applicationdistribution
Downside Connectionfront
Earth-leakage Protectionintegrated
Electrical Durability30000 cycles at 440 V In
50000 cycles at 440 V In/2
Height161 mm
Instantaneous Pick-up Adjustment Range1500 A
Instantaneous Pick-up Adjustment Type Iifixed
Local Signallingflashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Long Time Delay Adjustment Typefixed
Long Time Pick-up Adjustment Range40...100 A
Long Time Pick-up Adjustment Type Iradjustable 9 settings
Mechanical Durability50000 cycles
Mounting Modefixed
Net Weight2.4 kg
Network Frequency50/60 Hz
Neutral Protection Setting0.5 x Ir (3t + N/2)
1 x Ir (4t)
no protection (3t)
Number Of Slots5 slot(s)
Operating ModeOFF using the IΔn rotary switch
Power Losses5.8 W
Protection TypeI : for instantaneous short-circuit protection
L : for overload protection (long time)
R : for earth-leakage protection
So : for short time short-circuit protection with fixed delay
Residual Earth-leakage Sensitity Adjustment Typeadjustable
Residual Earth-leakage Time Delay Adjustment Typeadjustable
Short-time Delay Adjustment Typefixed
Short-time Pick-up Adjustment Type Isdadjustable
Thermal Memory20 minutes before and after tripping
Trip Unit Rating100-100 A at 40 °C
Upside Connectionfront
Width140 mm
Zone Selective Interlocking ZSIwithout
[Isd] Short-time Pick-up Adjustment Range1.5...10 x Ir
[IΔn] Residual Earth-leakage Sensitive Adjustment100-100 mA
1-1 A
300-300 mA
30-30 mA
3-3 A
500-500 mA
5-5 A
[tr] Long-time Delay Adjustment Range11-11 s at 7.2 x Ir
16-16 s at 6 x Ir
400-400 s at 1.5 x Ir
[tsd] Short-time Delay Adjustment Range0.02-0.02 s
[Uimp] Rated Impulse Withstand Voltage8 kV
[Ui] Rated Insulation Voltage500 V AC 50/60 Hz
[Δt] Residual Earth-leakage Time Delay Adjustment0-0 ms
1-1 s
150-150 ms
500-500 ms
60-60 ms
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-50-85 °C
Electrical Shock Protection Classclass II
IK Degree Of ProtectionIK07 conforming to IEC 62262
IP Degree Of ProtectionIP40 conforming to IEC 60529
Operating Altitude0...2000 m without derating
2000 m...5000 m with derating
Overvoltage Categoryclass II
Pollution Degree3 conforming to IEC 60664-1
Product CertificationsCCC
EAC
Marine
Relative Humidity0-95 %
StandardsEN/IEC 60947
OTHER
Earth Leakage CurrentMicrologic 4.2
Poles Description4P
[Us] Rated Supply VoltageComPacT NSX100...250 new generation
Write Your Own Review
You're reviewing:Circuit Breaker ComPacT NSX100B, 25kA At 415VAC, MicroLogic 4.2 Vigi Trip Unit 100A, 4 Poles 4d
Your Rating