APC Back-UPS 950VA, 230V, AVR, Universal and IEC Sockets.
Schneider
SKU
SE_BX950U-MS
Model
BX950U-MS
Obsolete
Short description of BX950U MS
Battery Backup & Surge Protector for Electronics and Computers
Obsolete
MAIN SPECIFICATIONS | |
---|---|
Physical Interface | 230 V |
Pressure Sensor Type | 480 W |
Rated Power In W | 480 W |
Cable Length | 4 ft |
Range Name | Back-UPS |
GENERAL | |
Additional Specification | entry level |
COMPLEMENTARY | |
Input Voltage | 230 V |
Output Voltage | 230 V |
Battery Life | 2-5 year(s) |
Battery Type | lead-acid battery |
Colour | black |
Data Line Protection | RJ11 modem/fax protection |
Depth | 33.6 cm |
Height | 21.5 cm |
Input Current | 4 A (1 phase) |
Input Protection Type | 3-pole circuit breaker |
Input Voltage Limits | 150...280 V |
Maximum Input Current | 4 A |
Mounting Mode | not rack-mountable |
Net Weight | 8 kg |
Network Frequency | 50/60 Hz +/- 3 Hz auto-sensing |
Output Frequency | 50/60 Hz +/- 1 Hz sync to mains 50/60 Hz +/- 1 Hz unsynchronised |
Provided Equipment | 1 x detachable 1.2 m IEC power cord 1 x detachable 2.0 m NEMA 5-15P to IEC C13 power cord user manual |
Rated Power In VA | 950 VA |
Switching Current Capacity | 7 A |
Transfer Time | 8 ms typical : 10 ms maximum |
Width | 13 cm |
COMMUNICATIONS & MANAGEMENT | |
Alarm | alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Control Panel | LED status display with on line : on battery : replace battery and overload indicators |
PHYSICAL | |
Battery Charger Power | 9 W rated |
Battery Curve | C |
Battery Recharge Time | 8 h |
Curve Equation | efficiency |
Curve Load Maximum | 100 % |
Curve X-axis Maximum | 100 % |
Curve X-axis Minimum | 0 % |
Curve X-axis Title | load |
Curve X-axis Units | percentage |
Curve Y-axis Maximum | 100 % |
Curve Y-axis Minimum | 50 % |
Curve Y-axis Title | efficiency |
Curve Y-axis Units | percentage |
Maximum Configurable Power In VA | 950 VA |
Maximum Configurable Power In W | 480 W |
Mounting Preference | no preference |
Nb Of Power Socket Outlets | 2 IEC 60320 C13 4 universal receptacle |
Number Of Tare Power | 15 W |
Redundant | no |
Show Note OP Temperature | no |
Size UPS Version | workstation |
Surge Energy Rate | 273 J |
UPS Type | line interactive |
USB Compatible | yes |
INPUT | |
Number Of Cables | 2 |
OUTPUT | |
Curve Fixed Loss | 0.0276 |
Curve Load Minimum | 3 % |
Curve Square Loss | 0.002 |
Curve Test Cond ID | Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced resistive load (PF = 1.0) output. |
Graph Display | 1 |
Wave Type | stepped approximation to a sinewave |
ENVIRONMENT | |
Ambient Air Temperature For Operation | 0-40 °C |
Ambient Air Temperature For Storage | -15-45 °C |
Operating Altitude | 0...10000 ft |
Relative Humidity | 0-95 % non-condensing |
ENVIRONMENTAL | |
Acoustic Level | 45 dBA |
Battery Power In VAh | 108 VAh capacity 76 VAh runtime |
Number Of Battery Filled Slots | 1 |
Plug Standard | IEC 60320 C14 NEMA 5-15P |
Storage Altitude | 0-30000 ft |
Storage Relative Humidity | 0-95 % non-condensing |
UPS Size | WS |