APC Back-UPS 950VA, 230V, AVR, Universal and IEC Sockets.

Schneider
SKU
SE_BX950U-MS
Model
BX950U-MS

Obsolete

Short description of BX950U MS

Battery Backup & Surge Protector for Electronics and Computers
Obsolete
*All information are subjected to changes without prior notice.
MAIN SPECIFICATIONS
Physical Interface230 V
Pressure Sensor Type480 W
Rated Power In W480 W
Cable Length4 ft
Range NameBack-UPS
GENERAL
Additional Specificationentry level
COMPLEMENTARY
Input Voltage230 V
Output Voltage230 V
Battery Life2-5 year(s)
Battery Typelead-acid battery
Colourblack
Data Line ProtectionRJ11 modem/fax protection
Depth33.6 cm
Height21.5 cm
Input Current4 A (1 phase)
Input Protection Type3-pole circuit breaker
Input Voltage Limits150...280 V
Maximum Input Current4 A
Mounting Modenot rack-mountable
Net Weight8 kg
Network Frequency50/60 Hz +/- 3 Hz auto-sensing
Output Frequency50/60 Hz +/- 1 Hz sync to mains
50/60 Hz +/- 1 Hz unsynchronised
Provided Equipment1 x detachable 1.2 m IEC power cord
1 x detachable 2.0 m NEMA 5-15P to IEC C13 power cord
user manual
Rated Power In VA950 VA
Switching Current Capacity7 A
Transfer Time8 ms typical : 10 ms maximum
Width13 cm
COMMUNICATIONS & MANAGEMENT
Alarmalarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Control PanelLED status display with on line : on battery : replace battery and overload indicators
PHYSICAL
Battery Charger Power9 W rated
Battery CurveC
Battery Recharge Time8 h
Curve Equationefficiency
Curve Load Maximum100 %
Curve X-axis Maximum100 %
Curve X-axis Minimum0 %
Curve X-axis Titleload
Curve X-axis Unitspercentage
Curve Y-axis Maximum100 %
Curve Y-axis Minimum50 %
Curve Y-axis Titleefficiency
Curve Y-axis Unitspercentage
Maximum Configurable Power In VA950 VA
Maximum Configurable Power In W480 W
Mounting Preferenceno preference
Nb Of Power Socket Outlets2 IEC 60320 C13
4 universal receptacle
Number Of Tare Power15 W
Redundantno
Show Note OP Temperatureno
Size UPS Versionworkstation
Surge Energy Rate273 J
UPS Typeline interactive
USB Compatibleyes
INPUT
Number Of Cables2
OUTPUT
Curve Fixed Loss0.0276
Curve Load Minimum3 %
Curve Square Loss0.002
Curve Test Cond IDCurve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced resistive load (PF = 1.0) output.
Graph Display1
Wave Typestepped approximation to a sinewave
ENVIRONMENT
Ambient Air Temperature For Operation0-40 °C
Ambient Air Temperature For Storage-15-45 °C
Operating Altitude0...10000 ft
Relative Humidity0-95 % non-condensing
ENVIRONMENTAL
Acoustic Level45 dBA
Battery Power In VAh108 VAh capacity
76 VAh runtime
Number Of Battery Filled Slots1
Plug StandardIEC 60320 C14
NEMA 5-15P
Storage Altitude0-30000 ft
Storage Relative Humidity0-95 % non-condensing