APC Back-UPS 700VA, 230V, AVR, IEC Sockets.
Schneider
SKU
SE_BX700UI
Model
BX700UI
Obsolete
Short description of BX700UI
Battery Backup & Surge Protector for Electronics and Computers
Obsolete
MAIN SPECIFICATIONS | |
---|---|
Physical Interface | 230 V |
Pressure Sensor Type | 390 W |
Rated Power In W | 390 W |
Cable Length | 4 ft |
Range Name | Back-UPS |
GENERAL | |
Additional Specification | entry level |
COMPLEMENTARY | |
Input Voltage | 230 V |
Output Voltage | 230 V |
Battery Graph Comments | This graph is based on actual measured runtime data. All measurements were taken with new, fully charged batteries and a balanced resistive load (PF = 1.0). Actual runtimes may vary from the values of this graph. Actual runtimes are dependent on several v |
Battery Life | 3-5 year(s) |
Battery Type | lead-acid battery |
Data Line Protection | RJ45 modem/fax/DSL/10-100 base-T protection |
Depth | 25.6 cm |
Height | 20 cm |
Input Voltage Limits | 140...300 V |
Mounting Mode | not rack-mountable |
Net Weight | 6 kg |
Network Frequency | 50/60 Hz +/- 3 Hz auto-sensing |
Output Frequency | 50/60 Hz +/- 1 Hz sync to mains |
Provided Equipment | user manual |
Rated Power In VA | 700 VA |
Switching Current Capacity | 7 A |
Transfer Time | 4 ms typical |
Width | 11.5 cm |
COMMUNICATIONS & MANAGEMENT | |
Alarm | alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Control Panel | LED status display with on line : on battery : replace battery and overload indicators |
PHYSICAL | |
Battery Charger Power | 14 W rated |
Battery Curve | B |
Battery Recharge Time | 6 h |
Curve Equation | efficiency |
Curve Load Maximum | 100 % |
Curve X-axis Maximum | 100 % |
Curve X-axis Minimum | 0 % |
Curve X-axis Title | load |
Curve X-axis Units | percentage |
Curve Y-axis Maximum | 100 % |
Curve Y-axis Minimum | 50 % |
Curve Y-axis Title | efficiency |
Curve Y-axis Units | percentage |
Maximum Configurable Power In VA | 700 VA |
Maximum Configurable Power In W | 390 W |
Mounting Preference | no preference |
Nb Of Power Socket Outlets | 1 IEC Jumpers 4 IEC 60320 C13 |
Number Of Battery Replacement Quantity | 1 |
Number Of Tare Power | 24 W |
Redundant | NO |
Show Note OP Temperature | NO |
Surge Energy Rate | 273 J |
UPS Type | line interactive |
USB Compatible | yes |
INPUT | |
Number Of Cables | 1 |
OUTPUT | |
Curve Fixed Loss | 0.033 |
Curve Load Minimum | 4 % |
Curve Square Loss | 0.0027 |
Curve Test Cond ID | Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced resistive load (PF = 1.0) output. |
Graph Display | 1 |
Wave Type | stepped approximation to a sinewave |
BATTERIES & RUNTIME | |
Battery Capacity | 7 Ah |
Battery Voltage | 12 V |
ENVIRONMENT | |
Ambient Air Temperature For Operation | 0-40 °C |
Ambient Air Temperature For Storage | -15-40 °C |
Operating Altitude | 0...10000 ft |
Relative Humidity | 0-95 % non-condensing |
ENVIRONMENTAL | |
Acoustic Level | 45 dBA |
Battery Power In VAh | 81 VAh capacity 84 VAh runtime |
Plug Standard | IEC 60320 C14 |
Storage Altitude | 0-30000 ft |
Storage Relative Humidity | 0-95 % non-condensing |
UPS Size | WS |