MAIN SPECIFICATIONS
Physical Interface230 V
Pressure Sensor Type390 W
Rated Power In W390 W
Cable Length4 ft
Range NameBack-UPS
GENERAL
Additional Specificationentry level
COMPLEMENTARY
Input Voltage230 V
Output Voltage230 V
Battery Graph CommentsThis graph is based on actual measured runtime data. All measurements were taken with new, fully charged batteries and a balanced resistive load (PF = 1.0). Actual runtimes may vary from the values of this graph. Actual runtimes are dependent on several v
Battery Life3-5 year(s)
Battery Typelead-acid battery
Data Line ProtectionRJ45 modem/fax/DSL/10-100 base-T protection
Depth25.6 cm
Height20 cm
Input Voltage Limits140...300 V
Mounting Modenot rack-mountable
Net Weight6 kg
Network Frequency50/60 Hz +/- 3 Hz auto-sensing
Output Frequency50/60 Hz +/- 1 Hz sync to mains
Provided Equipmentuser manual
Rated Power In VA700 VA
Switching Current Capacity7 A
Transfer Time4 ms typical
Width11.5 cm
COMMUNICATIONS & MANAGEMENT
Alarmalarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Control PanelLED status display with on line : on battery : replace battery and overload indicators
PHYSICAL
Battery Charger Power14 W rated
Battery CurveB
Battery Recharge Time6 h
Curve Equationefficiency
Curve Load Maximum100 %
Curve X-axis Maximum100 %
Curve X-axis Minimum0 %
Curve X-axis Titleload
Curve X-axis Unitspercentage
Curve Y-axis Maximum100 %
Curve Y-axis Minimum50 %
Curve Y-axis Titleefficiency
Curve Y-axis Unitspercentage
Maximum Configurable Power In VA700 VA
Maximum Configurable Power In W390 W
Mounting Preferenceno preference
Nb Of Power Socket Outlets1 IEC Jumpers
4 IEC 60320 C13
Number Of Battery Replacement Quantity1
Number Of Tare Power24 W
RedundantNO
Show Note OP TemperatureNO
Surge Energy Rate273 J
UPS Typeline interactive
USB Compatibleyes
INPUT
Number Of Cables1
OUTPUT
Curve Fixed Loss0.033
Curve Load Minimum4 %
Curve Square Loss0.0027
Curve Test Cond IDCurve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced resistive load (PF = 1.0) output.
Graph Display1
Wave Typestepped approximation to a sinewave
BATTERIES & RUNTIME
Battery Capacity7 Ah
Battery Voltage12 V
ENVIRONMENT
Ambient Air Temperature For Operation0-40 °C
Ambient Air Temperature For Storage-15-40 °C
Operating Altitude0...10000 ft
Relative Humidity0-95 % non-condensing
ENVIRONMENTAL
Acoustic Level45 dBA
Battery Power In VAh81 VAh capacity
84 VAh runtime
Plug StandardIEC 60320 C14
Storage Altitude0-30000 ft
Storage Relative Humidity0-95 % non-condensing
UPS SizeWS