Singapore GST will increase from 8% to 9%

(Effective from Jan 1, 2024)

Electgo: Your trusted Source for Electrical Components in Singapore

An Authorized Supplier Offering a Comprehensive Range of Electrical Component Categories

Loading...

APC Back-UPS 1600VA, 230V, AVR, Universal Sockets.

Schneider
SKU
SE_BX1600MI-MS
Model
BX1600MI-MS

Obsolete

Short description of BX1600MI MS

Battery Backup & Surge Protector for Electronics and Computers
Obsolete
*All information are subjected to changes without prior notice.
MAIN SPECIFICATIONS
Physical Interface230 V
Pressure Sensor Type900 W
Rated Power In W900 W
Cable Length4 ft
Range NameBack-UPS
GENERAL
Full Load Runtime00:01:00 900 W
Half Load Runtime00:06:30 450 W
Max Runtime240 min
COMPLEMENTARY
Input Voltage230 V
Output Voltage230 V
Battery Graph CommentsCurve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output.
Battery Life3-5 year(s)
Battery Typelead-acid battery
Colourblack
Cos Phi0.56
Data Line ProtectionRJ45 10/100/1000 Base-T Ethernet protection
Depth39 cm
Equipment Protection Policylifetime : 50000 euros
Height19 cm
Input Voltage Limits140...300 V
Mounting Modenot rack-mountable
Net Weight10.3 kg
Network Frequency50/60 Hz +/- 5 Hz auto-sensing
Output Frequency50/60 Hz +/- 1 Hz sync to mains
Provided Equipmentuser manual
Rated Power In VA1600 VA
Transfer Time6 ms typical : 10 ms maximum
Width14 cm
COMMUNICATIONS & MANAGEMENT
Alarmalarm when on battery : distinctive low battery alarm
Control PanelLED Status display with on line : on battery
PHYSICAL
Battery CurveC
Battery Recharge Time8 h
Curve Equationefficiency
Curve Load Maximum100 %
Curve X-axis Maximum100 %
Curve X-axis Minimum0 %
Curve X-axis Titleload
Curve X-axis Unitspercentage
Curve Y-axis Maximum100 %
Curve Y-axis Minimum50 %
Curve Y-axis Titleefficiency
Curve Y-axis Unitspercentage
Maximum Configurable Power In VA1600 VA
Maximum Configurable Power In W900 W
Mounting Preferenceno preference
Nb Of Power Socket Outlets4 universal
Number Of Tare Power20 W
Redundantno
Show Note OP Temperatureno
Surge Energy Rate273 J
UPS Typeline interactive
USB Compatibleno
INPUT
Number Of Cables1
OUTPUT
Curve Fixed Loss0.0206
Curve Load Minimum3 %
Curve Square Loss0.0106
Curve Test Cond IDCurve fit of data measured in accordance with the ENERGY STAR Test Method for Uninterruptible Power Supplies. All measurements taken in normal mode(s), at typical environmental conditions, with 230V/50Hz electrical input and balanced resistive load (PF =
Graph Display1
Wave Typestepped approximation to a sinewave
BATTERIES & RUNTIME
Battery Voltage24 V
ENVIRONMENT
Ambient Air Temperature For Operation0-40 °C
Ambient Air Temperature For Storage-15-40 °C
IP Degree Of ProtectionIP20
Operating Altitude0...3000 m
Product CertificationsCE
Relative Humidity0-95 % non-condensing
StandardsCE
EN/IEC 62040-1
EN/IEC 62040-2
ENVIRONMENTAL
Acoustic Level40 dBA
Battery Power In VAh136 VAh runtime
168 VAh capacity
Plug StandardIEC 60320 C14
Storage Altitude0-3000 m
Storage Relative Humidity0-95 % non-condensing
UPS SizeWS