APC Back-UPS 1600VA, 230V, AVR, Universal Sockets.
Schneider
SKU
SE_BX1600MI-MS
Model
BX1600MI-MS
Obsolete
Short description of BX1600MI MS
Battery Backup & Surge Protector for Electronics and Computers
Obsolete
MAIN SPECIFICATIONS | |
---|---|
Physical Interface | 230 V |
Pressure Sensor Type | 900 W |
Rated Power In W | 900 W |
Cable Length | 4 ft |
Range Name | Back-UPS |
GENERAL | |
Full Load Runtime | 00:01:00 900 W |
Half Load Runtime | 00:06:30 450 W |
Max Runtime | 240 min |
COMPLEMENTARY | |
Input Voltage | 230 V |
Output Voltage | 230 V |
Battery Graph Comments | Curve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output. |
Battery Life | 3-5 year(s) |
Battery Type | lead-acid battery |
Colour | black |
Cos Phi | 0.56 |
Data Line Protection | RJ45 10/100/1000 Base-T Ethernet protection |
Depth | 39 cm |
Equipment Protection Policy | lifetime : 50000 euros |
Height | 19 cm |
Input Voltage Limits | 140...300 V |
Mounting Mode | not rack-mountable |
Net Weight | 10.3 kg |
Network Frequency | 50/60 Hz +/- 5 Hz auto-sensing |
Output Frequency | 50/60 Hz +/- 1 Hz sync to mains |
Provided Equipment | user manual |
Rated Power In VA | 1600 VA |
Transfer Time | 6 ms typical : 10 ms maximum |
Width | 14 cm |
COMMUNICATIONS & MANAGEMENT | |
Alarm | alarm when on battery : distinctive low battery alarm |
Control Panel | LED Status display with on line : on battery |
PHYSICAL | |
Battery Curve | C |
Battery Recharge Time | 8 h |
Curve Equation | efficiency |
Curve Load Maximum | 100 % |
Curve X-axis Maximum | 100 % |
Curve X-axis Minimum | 0 % |
Curve X-axis Title | load |
Curve X-axis Units | percentage |
Curve Y-axis Maximum | 100 % |
Curve Y-axis Minimum | 50 % |
Curve Y-axis Title | efficiency |
Curve Y-axis Units | percentage |
Maximum Configurable Power In VA | 1600 VA |
Maximum Configurable Power In W | 900 W |
Mounting Preference | no preference |
Nb Of Power Socket Outlets | 4 universal |
Number Of Tare Power | 20 W |
Redundant | no |
Show Note OP Temperature | no |
Surge Energy Rate | 273 J |
UPS Type | line interactive |
USB Compatible | no |
INPUT | |
Number Of Cables | 1 |
OUTPUT | |
Curve Fixed Loss | 0.0206 |
Curve Load Minimum | 3 % |
Curve Square Loss | 0.0106 |
Curve Test Cond ID | Curve fit of data measured in accordance with the ENERGY STAR Test Method for Uninterruptible Power Supplies. All measurements taken in normal mode(s), at typical environmental conditions, with 230V/50Hz electrical input and balanced resistive load (PF = |
Graph Display | 1 |
Wave Type | stepped approximation to a sinewave |
BATTERIES & RUNTIME | |
Battery Voltage | 24 V |
ENVIRONMENT | |
Ambient Air Temperature For Operation | 0-40 °C |
Ambient Air Temperature For Storage | -15-40 °C |
IP Degree Of Protection | IP20 |
Operating Altitude | 0...3000 m |
Product Certifications | CE |
Relative Humidity | 0-95 % non-condensing |
Standards | CE EN/IEC 62040-1 EN/IEC 62040-2 |
ENVIRONMENTAL | |
Acoustic Level | 40 dBA |
Battery Power In VAh | 136 VAh runtime 168 VAh capacity |
Plug Standard | IEC 60320 C14 |
Storage Altitude | 0-3000 m |
Storage Relative Humidity | 0-95 % non-condensing |
UPS Size | WS |