APC Back-UPS 500, 230V Without Auto Shutdown Software, ASEAN.
Schneider
SKU
SE_BR500CI-AS
Model
BR500CI-AS
Obsolete
Short description of BR500CI AS
Battery Backup & Surge Protector for Electronics and Computers
Obsolete
MAIN SPECIFICATIONS | |
---|---|
Physical Interface | 230 V |
Pressure Sensor Type | 300 W |
Rated Power In W | 300 W |
Cable Length | 6 ft |
Range Name | Back-UPS |
GENERAL | |
Max Runtime | 28 min |
Performance Multiplier | 1 |
Value Multiplier | 1 |
COMPLEMENTARY | |
Input Voltage | 230 V |
Output Voltage | 230 V |
Battery Graph Comments | This graph is based on actual measured runtime data. All measurements were taken with new, fully charged batteries and a balanced resistive load (PF = 1.0). Actual runtimes may vary from the values of this graph. Actual runtimes are dependent on several v |
Battery Life | 2-4 year(s) |
Battery Type | lead-acid battery |
Colour | black |
Depth | 21.3 cm |
Height | 18.5 cm |
Mounting Mode | not rack-mountable |
Net Weight | 4.9 kg |
Network Frequency | 50/60 Hz +/- 3 Hz auto-sensing |
Output Frequency | 47...63 Hz sync to mains |
Provided Equipment | 2 x detachable 1.8 m IEC power cords user manual warranty card |
Rated Power In VA | 500 VA |
Transfer Time | 6 ms typical : 10 ms maximum |
Width | 11.5 cm |
COMMUNICATIONS & MANAGEMENT | |
Alarm | alarm when on battery : distinctive low battery alarm |
PHYSICAL | |
Battery Charger Power | 7 W rated |
Battery Curve | B |
Battery Recharge Time | 10 H |
Curve Equation | efficiency |
Curve Load Maximum | 100 % |
Curve X-axis Maximum | 100 % |
Curve X-axis Minimum | 0 % |
Curve X-axis Title | load |
Curve X-axis Units | percentage |
Curve Y-axis Maximum | 100 % |
Curve Y-axis Minimum | 50 % |
Curve Y-axis Title | efficiency |
Curve Y-axis Units | percentage |
Maximum Configurable Power In VA | 500 VA |
Maximum Configurable Power In W | 300 W |
Mounting Preference | no preference |
Nb Of Power Socket Outlets | 3 IEC 60320 C13 |
Number Of Battery Replacement Quantity | 1 |
Number Of Tare Power | 12 W |
Redundant | no |
Show Note OP Temperature | no |
Surge Energy Rate | 240 J |
UPS Type | line interactive |
USB Compatible | no |
INPUT | |
Number Of Cables | 1 |
OUTPUT | |
Graph Display | 1 |
Wave Type | stepped approximation to a sinewave |
ENVIRONMENT | |
Ambient Air Temperature For Operation | 0-40 °C |
Ambient Air Temperature For Storage | -15-45 °C |
Operating Altitude | 0...10000 ft |
Relative Humidity | 0-95 % |
ENVIRONMENTAL | |
Battery Power In VAh | 73 VAh runtime |
Plug Standard | IEC 60320 C14 |
Storage Altitude | 0-50000 ft |
Storage Relative Humidity | 0-95 % |
UPS Size | WS |