Singapore GST will increase from 8% to 9%

(Effective from Jan 1, 2024)

Electgo: Your trusted Source for Electrical Components in Singapore

An Authorized Supplier Offering a Comprehensive Range of Electrical Component Categories

Loading...

Variable Speed Drive, Altivar Machine ATV340, 5.5 KW, 400 V, 3 Phases,

Schneider
SKU
SE_ATV340U55N4
Model
ATV340U55N4
SGD $1,112.85

Short description of ATV340U55N4

ATV340 5,5KW 7,5HP 400V WO ETHERNET VARI
Country of Origin
Indonesia
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
variable speed drive
-  5.5kW
-  400V
-  3 phases
-  ATV340.
Label :  Altivar Machine ATV340
-  range of product :  Altivar Machine ATV340
-  IP degree of protection :  N/A, N/A
-  type of cooling :  forced convection
-  supply frequency :  50...60 Hz +/- 5 %
-  network number of phases :  3 phases
-  [Us] rated supply voltage :  380...480 V
-  15...10 %
-  motor power kW :  7.5 kWfor normal duty, 5.5 kWfor heavy duty
-  motor power hp :  10 hpfor normal duty, 7 hpfor heavy duty
-  line current :  N/A, N/A, N/A, N/A, N/A, N/A
-  prospective line Isc :  22 kA
-  product or component type :  variable speed drive
-  apparent power :  12.1 kVA at 480 V (normal duty), 13.3 kVA at 480 V (heavy duty)
-  continuous output current :  16.5 A at 4 kHzfor normal duty, 12.7 A at 4 kHzfor heavy duty
-  maximum transient current :  18.2 A during 60 s (normal duty), 19.1 A during 60 s (heavy duty), 22.3 A during 2 s (normal duty), 22.9 A during 2 s (heavy duty)
-  asynchronous motor control profile :  variable torque standard,optimized torque mode,constant torque standard
-  synchronous motor control profile :  permanent magnet motor,reluctance motor
-  speed drive output frequency :  0.1-599 Hz
-  nominal switching frequency :  4 kHz
-  switching frequency :  2...16 kHz adjustable, 7...16 kHz with derating factor
-  safety function :  STO (safe torque off) SIL 3
-  device application :  machine
-  device short name :  ATV340
-  variant :  standard version
-  product destination :  asynchronous motors,synchronous motors
-  mounting mode :  cabinet mount
-  EMC filter :  integrated conforming to EN/IEC 61800-3 category C3 with 20 m
-  Range Presentation :  Designed for optimized installation, the Altivar Machine ATV340 drive offers cutting edge application control and advanced, easy to integrate automation capabilities. Its innovative features make it the drive of choice for OEMs entering – and rising to the challenges of – the smart machine era. The Altivar Machine ATV340 variable speed drives offer top level automation capabilities and outstanding motor control technology combined with simplicity. Altivar Machine ATV340 was engineered to maximize machine performance, reduce machine build time and sustain machine productivity.
-  Range Benefits : 
Superior machine performance
Powerful dynamism and scalability
The Altivar Machine 340 is a powerful drive that aims to match your machine’s motor capabilities with maximum torque and speed performance. With an optimized speed bandwidth up to 400 Hz, the Altivar Machine 340 is designed for dynamic applications that may require faster acceleration or settling time.
-  The Altivar Machine 340 frequency inverters are very robust for high overloads, adaptable to the needs of demanding applications up to 220% nominal torque.
-  To meet the adaptability and the scalability your machine requires, Altivar Machine 340 is compatible with a wide range of motors such as asynchronous (IE2, IE3); synchronous; reluctance motors (IE4, IE5) for various applications in closed; and open loop.
Unprecedented automation performance
The Altivar Machine 340 will bring your machine to the next level of automation reaction time. Its real-time capabilities achieve the best possible machine control. The combination of ATV340 minimum application reaction time (1ms task cycle) and Ethernet connectivity in real-time, maximize your machine throughput.
Reduced machine design timeThe Altivar Machine 340 will help you reduce your engineering time at every stage of the process so your machine is up and running sooner.
Simplified machine engineering
The Altivar Machine 340 accommodates numerous functions and features to simplify the machine design and reduces the engineering time from selection to commissioning.
-  Enriched variety of interfaces, numerous I/Os, Multi Ethernet protocol, PTI/PTO, embedded encoder as well as multiple option interfaces offers maximum flexibility in architecture design
-  Simple master slave configuration, positioning mode, integrated application functions facilitate and fulfill application performance for hoisting, material handling, material working and packaging machines.
Seamless automation integration
Ready
- to
- use EcoStruxure Machine application libraries that are Tested Validated and Documented (TVDA), combined with Ethernet services available in Altivar Machine 340 will facilitate your machine design and help you significantly reduce design time.
-  The ONE button auto
- tuning for motor identification gives users the possibility to replicate the complete project in a fast and seamless manner ensuring maximum productivity in machine commissioning and production.
Sustained machine operation
Robust design for long
- lasting operation and reliable service
Altivar Machine 340 has been designed to fulfil application requirements for harsh environments, such as vibration, shock and non
- conductive dust and where high temperature resistance up to 60°C is needed.
-  Compliant with IEC60721-3-3 Class 3C3 and 3S3
Protect people and assets while ensuring continuity of service
The Altivar Machine 340 is compliant with machine safety and cybersecurity standards to ensure enduring protection of your people and assets
-  Compliant with machine
- related safety standards EN ISO 13849-1 and EN
- 62061
-  Achilles level 2 certification against cyber attacks
Fast machine recovery
The Altivar Machine 340 keeps your machine up and running with minimal downtime due to features that include : 
-  Faulty Device Replacement (FDR) service with the EcoStruxure Machine architecture in place, device replacement takes only two simple steps by the service technician. Easy device replacement, thanks to pluggable connectors, mounting a new drive takes less than three minutes and drive configuration is automatically downloaded from the PLC.
-  Data logging and monitoring through the local system or remote monitoring via the embedded web server ensure users have access to any motor or application
- relevant data anytime, anywhere. This
-  Range Application Presentation :  High performance application requirement and superior automation capabilities for
-  Packaging,
-  Material Working,
-  Material Handling,
-  Hoisting machine segments.
MAIN SPECIFICATIONS
Analog/digital Conversionsoftware-configurable current AQ1: 0...20 mA impedance 500 Ohm, resolution 10 bits
software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Analogue Input Number2
Analogue Input Range2
Discrete Input Number5
Discrete Output Typeprogrammable output DQ1, DQ2 30 V DC 100 mA
Display Type2-wire RS 485
Measurement Accuracy connector(s)1 x RJ45, Modbus serial for HMI on front face
connector(s)1 x RJ45, Modbus serial on front face
1 RJ45
Physical Interface2-wire RS 485
Product Or Component Typevariable speed drive
Range Of ProductAltivar Machine ATV340
Communication Port ProtocolModbus serial
Design Of Frequency ChangerU converter
EAN133606480966927
EMC Filterclass C3 EMC filter integrated
Line Current11.6 A at 380 V with external line choke (heavy duty)
12.2 A at 480 V (normal duty)
12.2 A at 480 V with external line choke (normal duty)
15.3 A at 380 V (normal duty)
15.3 A at 380 V with external line choke (normal duty)
16 A at 480 V without line choke (heavy duty)
16.0 A at 480 V (heavy duty)
20 A at 380 V without line choke (heavy duty)
20.0 A at 380 V (heavy duty)
9.4 A at 480 V with external line choke (heavy duty)
Method Of Accessslave Modbus RTU
Motor Power Hp10 hp for normal duty
7 hp for heavy duty
Network Number Of Phases3 phases
Number Of Input Phases3
Number Of Output Phases3
Product Specific Applicationmachine
Range NameAltivar 340
Relative Symmetric Mains Voltage Tolerance10 %
COMPLEMENTARY
Analogue Input TypeAI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
AI1 software-configurable temperature probe or water level sensor
AI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
AI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Analogue Output Number2
Analogue Output Typesoftware-configurable current AQ1: 0...20 mA impedance 500 Ohm, resolution 10 bits
software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Connector Type connector(s)1 x RJ45, Modbus serial for HMI on front face
connector(s)1 x RJ45, Modbus serial on front face
1 RJ45
Discrete Output Number2
Output Voltage<= power supply voltage
Port Ethernet2
[Ics] Rated Service Breaking Capacityprogrammable output DQ1, DQ2 30 V DC 100 mA
1 Phase Low Current Possiblefalse
4 Quadrant Operation Possibletrue
Acceleration And Deceleration Rampslinear adjustable separately from 0.01...9999 s
S, U or customized
Accuracy+/- 0.6 % AI1, AI2 for a temperature variation 60 °C analog input
+/- 1 % AQ1 for a temperature variation 60 °C analog output
Apparent Power12.1 kVA at 480 V (normal duty)
13.3 kVA at 480 V (heavy duty)
Application In Domestic And Commercial Area Permittedfalse
Application In Industrial Area Permittedtrue
Assembly Stylewith heat sink
Asynchronous Motor Control Profileconstant torque standard
optimized torque mode
variable torque standard
Base Load Current At High Overload12.7 A
Base Load Current At Low Overload16.5 A
Brake Chopper Integratedtrue
Braking To Standstillby DC injection
Capacity Of DC Link750 µF
Computer Porttrue
Continuous Output Current12.7 A at 4 kHz for heavy duty
16.5 A at 4 kHz for normal duty
Data Format8 bits, configurable odd, even or no parity
Depth234 mm
Discrete Input Logic16 preset speeds
negative logic (sink) (DI1...DI5), > 16 V (state 0), < 10 V (state 1)
positive logic (source) (DI1...DI5), < 5 V (state 0), > 11 V (state 1)
positive logic (source) (PTI), < 0.6 V (state 0), > 2.5 V (state 1)
positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
Discrete Input Type programmable
DI1...DI5 safe torque off, 24 V DC (30 V), impedance: 3.5 kOhm
PTI programmable as pulse input: 0-30 kHz, 24 V DC (30 V)
Electrical Connectioncontrol: screw terminal 0.2...2.5 mm²/AWG 24...AWG 12
DC bus: screw terminal 4...6 mm²/AWG 12...AWG 10
line side: screw terminal 1.5...6 mm²/AWG 14...AWG 10
motor: screw terminal 1.5...6 mm²/AWG 14...AWG 10
screw terminal, clamping capacity: 0.2...2.5 mm² for control
screw terminal, clamping capacity: 1.5...6 mm² for line side
screw terminal, clamping capacity: 1.5...6 mm² for motor
screw terminal, clamping capacity: 4...6 mm² for DC bus
EMC Limit Value (complied)true
Encoder Protocol1 Vpp
EnDat 2.2
resolver
RS 422
SSI 24V
SSI 5V
TTL/HTL
Height270 mm
Housing Materialplastic
Input CompatibilityDI1...DI5: discrete input level 1 PLC conforming to EN/IEC 61131-2
PTI: pulse input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
Input/output Typeprogrammable as logic input/output DQ1: 0-1 kHz, <= 30 V DC, 100 mA
programmable as logic input/output DQ2: 0-1 kHz, <= 30 V DC, 100 mA
Insulation Resistance> 1 MOhm 500 V DC for 1 minute to earth
Isolationbetween power and control terminals
Linearity ErrorAI1, AI2: +/- 0.15 % of maximum value for analog input
AQ1: +/- 0.2 % for analog output
MarkingCE
Maximum Associated Fuse Rating40 A
Maximum Input Current20 A
Maximum Output Frequency0.599 kHz
Maximum Output Voltage480 V
Maximum Switching Currentrelay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
relay output R1C on resistive load, cos phi = 1 : 3 A at 250 V AC
relay output R1C on resistive load, cos phi = 1 : 3 A at 30 V DC
relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
relay output R2C on resistive load, cos phi = 1 : 5 A at 250 V AC
relay output R2C on resistive load, cos phi = 1 : 5 A at 30 V DC
Maximum Transient Current18.2 A during 60 s (normal duty)
19.1 A during 60 s (heavy duty)
22.3 A during 2 s (normal duty)
22.9 A during 2 s (heavy duty)
Minimum Switching Currentrelay output R1B: 5 mA at 24 V DC
relay output R2C: 5 mA at 24 V DC
Motor Power KW5.5 kW for heavy duty
7.5 kW for normal duty
Motor Slip Compensationadjustable
automatic whatever the load
can be suppressed
not available in permanent magnet motor law
Motor Starter Typevariable speed drive
Mounting Modecabinet mount
Net Weight2.9 kg
Network Frequency50...60 Hz
Nominal Output Current12.7 A
Nominal Output Power5.5 kW
Nominal Switching Frequency4 kHz
Number Of Addresses1-247
Number Of HW Interfaces Serial RS4851
Operating Element Presenttrue
Operating Positionvertical +/- 10 degree
Optical Interface Presentfalse
Option Cardcommunication module, CANopen
communication module, DeviceNet
communication module, EtherCAT
communication module, Profibus DP V1
communication module, Profinet
Power Dissipation In Wforced convection: 134 W at 380 V, switching frequency 4 kHz (heavy duty)
forced convection: 164 W at 380 V, switching frequency 4 kHz (normal duty)
natural convection: 134 W at 380 V, switching frequency 4 kHz (heavy duty)
natural convection: 164 W at 380 V, switching frequency 4 kHz (normal duty)
Power Loss Per Device Current Dependent196 W
Power Loss Static Current Independent16 W
Power Range4-6 kW at 380-440 V 3 phases
4-6 kW at 480-500 V 3 phases
Prospective Line Isc22 kA
Protection Typebreak on the control circuit: drive
DC Bus overvoltage: drive
exceeding limit speed: drive
input supply loss: drive
line supply overvoltage: drive
line supply undervoltage: drive
motor phase loss: drive
motor phase loss: motor
output overcurrent between motor phase and earth: drive
output overcurrent between motor phases: drive
overcurrent: drive
overheating: drive
safe torque off: drive
safe torque off: motor
short-circuit between motor phase and earth: drive
short-circuit between motor phases: drive
thermal protection: drive
thermal protection: motor
Refresh Timerelay output (R1, R2): 5 ms (+/- 0.5 ms)
Relative Symmetric Network Frequency Tolerance5 %
Relay Output Number2
Relay Output Typerelay outputs R1A
relay outputs R1C electrical durability 100000 cycles
relay outputs R2A
relay outputs R2C electrical durability 100000 cycles
Safety FunctionSTO (safe torque off) SIL 3
Sampling Duration1 ms +/- 1 ms (AI1, AI2) - analog input
2 ms +/- 0.5 ms (DI1...DI5) - discrete input
2 ms +/- 0.5 ms (DQ1, DQ2) - discrete input/output
5 ms +/- 1 ms (AQ1) - analog output
5 ms +/- 1 ms (PTI) - pulse input
Specific Applicationmachine
Speed Drive Output Frequency0.1-599 Hz
Supply Frequency50...60 Hz +/- 5 %
Supporting Protocol For AS-Interface Safety At Workfalse
Supporting Protocol For ASIfalse
Supporting Protocol For BACnetfalse
Supporting Protocol For CANtrue
Supporting Protocol For Data-Highwayfalse
Supporting Protocol For DeviceNetfalse
Supporting Protocol For DeviceNet Safetyfalse
Supporting Protocol For EtherNet/IPfalse
Supporting Protocol For Foundation Fieldbusfalse
Supporting Protocol For INTERBUSfalse
Supporting Protocol For INTERBUS-Safetyfalse
Supporting Protocol For KNXfalse
Supporting Protocol For LONfalse
Supporting Protocol For MODBUStrue
Supporting Protocol For Other Bus Systemstrue
Supporting Protocol For PROFIBUStrue
Supporting Protocol For PROFINET CBAtrue
Supporting Protocol For PROFINET IOtrue
Supporting Protocol For PROFIsafefalse
Supporting Protocol For SafetyBUS Pfalse
Supporting Protocol For SERCOSfalse
Supporting Protocol For SUCONETfalse
Supporting Protocol For TCP/IPfalse
Switching Frequency2...16 kHz adjustable
7...16 kHz with derating factor
Synchronous Motor Control Profilepermanent magnet motor
reluctance motor
Transmission FrameRTU
Transmission Rate19.2 kbit/s
38.4 kbit/s
4.8 kbit/s
9.6 kbit/s
Type Of Coolingforced convection
Type Of Polarizationno impedance
Width110 mm
With Safety Function Safe Brake Management (SBC/SBT)true
With Safety Function Safe Direction (SDI)false
With Safety Function Safe Operating Stop (SOS)false
With Safety Function Safe Position (SP)false
With Safety Function Safe Programmable Logicfalse
With Safety Function Safe Speed Monitor (SSM)false
With Safety Function Safe Stop 1 (SS1)true
With Safety Function Safe Torque Off (STO)true
With Safety Function Safely Limited Position (SLP)false
With Safety Function Safely Limited Speed (SLS)true
With Sft Fct Safe Stop 2 (SS2)false
ENVIRONMENT
Ambient Air Temperature For Operation-15-50 °C without derating (vertical position)
-15-60 °C
50-60 °C with derating factor (vertical position)
Ambient Air Temperature For Storage-40-70 °C
Ambient Air Transport Temperature-40-70 °C
Electromagnetic Compatibility1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Environmental Class (during Operation)class 3C3 according to IEC 60721-3-3
class 3S3 according to IEC 60721-3-3
Environmental Class (during Storage)class 1C3 according to EN 60721-3-1
class 1S2 according to EN 60721-3-1
Environmental Class (during Transport)class 2C3 according to EN 60721-3-2
class 2S1 according to EN 60721-3-2
IP Degree Of ProtectionIP20
Maximum Acceleration Under Shock Impact (during Operation)70 m/s² at 22 ms
Maximum Acceleration Under Shock Load (during Storage)70 m/s² at 22 ms
Maximum Acceleration Under Shock Load (during Transport)70 m/s² at 22 ms
Maximum Acceleration Under Vibrational Stress (during Operation)5 m/s² at 9...200 Hz
Maximum Acceleration Under Vibratory Load (during Storage)5 m/s² at 9...200 Hz
Maximum Acceleration Under Vibratory Load (during Transport)5 m/s² at 9...200 Hz
Maximum Deflection Under Vibratory Load (during Operation)1.5 mm at 2...9 Hz
Maximum Deflection Under Vibratory Load (during Storage)1.5 mm at 2...9 Hz
Maximum Deflection Under Vibratory Load (during Transport)1.5 mm at 2...9 Hz
NEMA Degree Of Protectionnot applicable
Noise Level46.6 dB
Operating Altitude<= 3000 m with current derating above 1000m
Overvoltage Categoryclass III
Permitted Relative Humidity (during Operation)class 3K5 according to EN 60721-3
Permitted Relative Humidity (during Storage)class 1K5 according to EN 60721-3
Permitted Relative Humidity (during Transport)class 2K5 according to EN 60721-3
Pollution Degree2 conforming to EN/IEC 61800-5-1
2
Product CertificationsCSA
CTick
EAC
TÜV
UL
Regulation Loopadjustable PID regulator
Shock Resistance15 gn for 11 ms, class 3M3 conforming to EN/IEC 60721-3-3
StandardsEN/IEC 61800-3
EN/IEC 61800-5-1
IEC 13849-1
IEC 60721-3
IEC 61508
UL 508C
UL 618000-5-1
Vibration Resistance1 gn (f= 9-200 Hz) conforming to EN/IEC 60721-3-3 class 3M3
1.5 mm peak to peak (f= 2-19 Hz) conforming to EN/IEC 60721-3-3 class 3M3
Volume Of Cooling Air76 m3/h
OTHER
Poles Descriptionvariable speed drive
[Us] Rated Supply Voltage380...480 V
380...480 V - 15...10 %