Soft Starter for Asynchronous Motor - ATS48 - 124 A - 208..690 V - 30..110 KW
Schneider
SKU
SE_ATS48C14Y
Model
ATS48C14Y
Obsolete
Short description of ATS48C14Y
SOFT START SOFT STOP UNIT ALTISTART 140A
Obsolete
soft starter for asynchronous motor
-  ATS48
-  124 A-208..690 V
-  30..110 KW.
Label :  Altistart 48
-  range of product :  Altistart 48
-  motor power kW :  110 kW at 660 V for standard applications, 75 kW at 525 V for severe applications, 90 kW at 500 V for standard applications, 90 kW at 525 V for standard applications, 90 kW at 660 V for severe applications, 90 kW at 690 V for severe applications, 110 kW at 690 V for standard applications, 30 kW at 230 V for severe applications, 37 kW at 230 V for standard applications, 55 kW at 400 V for severe applications, 55 kW at 440 V for severe applications, 75 kW at 400 V for standard applications, 75 kW at 440 V for standard applications, 75 kW at 500 V for severe applications
-  motor power hp :  100 hp at 460 V for standard applications, 100 hp at 575 V for severe applications, 125 hp at 575 V for standard applications, 30 hp at 208 V for severe applications, 40 hp at 208 V for standard applications, 40 hp at 230 V for severe applications, 50 hp at 230 V for standard applications, 75 hp at 460 V for severe applications
-  power dissipation in W :  306 W for standard applications, 391 W for standard applications
-  utilisation category :  AC
- 53A
-  product or component type :  soft starter
-  type of start :  start with torque control (current limited to 5 In)
-  product destination :  asynchronous motors
-  IcL starter rating :  110 A for standard applications, 140 A for standard applications
-  product specific application :  heavy duty industry and pumps
-  IP degree of protection :  N/A
-  device short name :  ATS48
-  [Us] rated supply voltage :  208...690 V
-  15...10 %
-  Range Presentation :  230... 415 V / 208... 690 V
-  50/60 Hz
-  Starting and stopping of the machine by the Altistart 48 torque control system (TCS patent :  Torque Control System)
-  Thermal protection of the motor
-  Protection of the machine :  underload and overload with adjustable threshold and times, locked rotor, rotation direction control
-  Factory set for immediate start-up
-  Simplified customisation of settings using built-in display or the PowerSuite software
-  Through connection
-  Control of starter bypass contactor to prevent heat dissipation
-  Dual configuration (2 motors)
-  Numerous configurable inputs/outputs
-  Cascaded starting and deceleration of a number of motors
-  Modbus Integrated, FIPIO, PROFIBUS DP, DeviceNet, Ethernet
-  Range Benefits :  Taming energy
Altistart 48 offers you the benefits of its patented Torque Control System (TCS). Ready for immediate start-up, with simplified wiring and extended communication functions, it can be integrated at the heart of your applications in complete simplicity.
-  Range Application Presentation : 
-  Pumps
-  Fans and high inertia machines
-  Compressors
-  Conveyors
-  ATS48
-  124 A-208..690 V
-  30..110 KW.
Label :  Altistart 48
-  range of product :  Altistart 48
-  motor power kW :  110 kW at 660 V for standard applications, 75 kW at 525 V for severe applications, 90 kW at 500 V for standard applications, 90 kW at 525 V for standard applications, 90 kW at 660 V for severe applications, 90 kW at 690 V for severe applications, 110 kW at 690 V for standard applications, 30 kW at 230 V for severe applications, 37 kW at 230 V for standard applications, 55 kW at 400 V for severe applications, 55 kW at 440 V for severe applications, 75 kW at 400 V for standard applications, 75 kW at 440 V for standard applications, 75 kW at 500 V for severe applications
-  motor power hp :  100 hp at 460 V for standard applications, 100 hp at 575 V for severe applications, 125 hp at 575 V for standard applications, 30 hp at 208 V for severe applications, 40 hp at 208 V for standard applications, 40 hp at 230 V for severe applications, 50 hp at 230 V for standard applications, 75 hp at 460 V for severe applications
-  power dissipation in W :  306 W for standard applications, 391 W for standard applications
-  utilisation category :  AC
- 53A
-  product or component type :  soft starter
-  type of start :  start with torque control (current limited to 5 In)
-  product destination :  asynchronous motors
-  IcL starter rating :  110 A for standard applications, 140 A for standard applications
-  product specific application :  heavy duty industry and pumps
-  IP degree of protection :  N/A
-  device short name :  ATS48
-  [Us] rated supply voltage :  208...690 V
-  15...10 %
-  Range Presentation :  230... 415 V / 208... 690 V
-  50/60 Hz
-  Starting and stopping of the machine by the Altistart 48 torque control system (TCS patent :  Torque Control System)
-  Thermal protection of the motor
-  Protection of the machine :  underload and overload with adjustable threshold and times, locked rotor, rotation direction control
-  Factory set for immediate start-up
-  Simplified customisation of settings using built-in display or the PowerSuite software
-  Through connection
-  Control of starter bypass contactor to prevent heat dissipation
-  Dual configuration (2 motors)
-  Numerous configurable inputs/outputs
-  Cascaded starting and deceleration of a number of motors
-  Modbus Integrated, FIPIO, PROFIBUS DP, DeviceNet, Ethernet
-  Range Benefits :  Taming energy
Altistart 48 offers you the benefits of its patented Torque Control System (TCS). Ready for immediate start-up, with simplified wiring and extended communication functions, it can be integrated at the heart of your applications in complete simplicity.
-  Range Application Presentation : 
-  Pumps
-  Fans and high inertia machines
-  Compressors
-  Conveyors
MAIN SPECIFICATIONS | |
---|---|
Analog/digital Conversion | current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm |
Analogue Input Number | 208...690 V - 15...10 % |
Discrete Input Number | 5 |
Discrete Output Type | (LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
Display Type | RS485 multidrop |
Measurement Accuracy | 1 RJ45 |
Physical Interface | RS485 multidrop |
Product Or Component Type | soft starter |
Range Of Product | Altistart 48 |
Communication Port Protocol | Modbus |
Device Short Name | ATS48 |
Discrete Input Voltage | 24 V <= 30 V |
EAN13 | 3389110982367 |
Function Available | external bypass (optional) |
IcL Starter Rating | 140 A for connection in the motor supply line for severe applications 140 A for connection in the motor supply line for standard applications |
Motor Power Hp | 100 hp at 460 V for standard applications 100 hp at 575 V for severe applications 125 hp at 575 V for standard applications 30 hp at 208 V for severe applications 40 hp at 208 V for standard applications 40 hp at 230 V for severe applications 50 hp at 230 V for standard applications 75 hp at 460 V for severe applications |
Product Specific Application | heavy duty industry and pumps |
Range Name | Altistart 48 |
Type Of Start | start with torque control (current limited to 5 In) |
Utilisation Category | AC-53A |
COMPLEMENTARY | |
Analogue Input Type | 5 |
Analogue Output Type | current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm |
Connector Type | 1 RJ45 |
Discrete Output Number | 2 |
Port Ethernet | 2 |
[Ics] Rated Service Breaking Capacity | (LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
Assembly Style | with heat sink |
Communication Data Link | serial |
Depth | 265 mm |
Device Connection | in the motor supply line |
Discrete Input Logic | positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
Discrete Input Type | (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm PTC, 750 Ohm at 25 °C |
Height | 340 mm |
Installed Device | 31 |
Marking | CE |
Maximum Switching Current | logic output 0.2 A at 30 V DC relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 ms relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms |
Minimum Switching Current | 10 mA at 6 V DC for relay outputs |
Motor Power KW | 110 kW at 660 V for standard applications 110 kW at 690 V for standard applications 30 kW at 230 V for severe applications 37 kW at 230 V for standard applications 55 kW at 400 V for severe applications 55 kW at 440 V for severe applications 75 kW at 400 V for standard applications 75 kW at 440 V for standard applications 75 kW at 500 V for severe applications 75 kW at 525 V for severe applications 90 kW at 500 V for standard applications 90 kW at 525 V for standard applications 90 kW at 660 V for severe applications 90 kW at 690 V for severe applications |
Motor Starter Type | soft starter |
Net Weight | 12.4 kg |
Network Frequency | 47.5...63 Hz |
Operating Position | vertical +/- 10 degree |
Output Absolute Accuracy Precision | +/- 5 % |
Power Dissipation In W | 306 W for standard applications 391 W for standard applications |
Power Range | 30-50 kW at 200-240 V 3 phases 55-100 kW at 380-440 V 3 phases 55-100 kW at 480-500 V 3 phases |
Product Destination | asynchronous motors |
Protection Type | phase failure: line thermal protection: motor thermal protection: starter |
Supply Frequency | 50...60 Hz - 5...5 % |
Supply Inrush Current | 0.4...1.3 Icl adjustable |
Transmission Rate | 4800, 9600 or 19200 bps |
Width | 200 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -10-40 °C (without derating) 40-60 °C (with current derating of 2 % per °C) |
Ambient Air Temperature For Storage | -25-70 °C |
Electromagnetic Compatibility | conducted and radiated emissions level A conforming to IEC 60947-4-2 conducted and radiated emissions level B conforming to IEC 60947-4-2 damped oscillating waves level 3 conforming to IEC 61000-4-12 electrostatic discharge level 3 conforming to IEC 61000-4-2 immunity to electrical transients level 4 conforming to IEC 61000-4-4 immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 voltage/current impulse level 3 conforming to IEC 61000-4-5 |
Noise Level | 50 dB |
Operating Altitude | <= 1000 m without derating > 1000...2000 m with current derating of 2.2 % per additional 100 m |
Product Certifications | CCC CSA C-Tick DNV GOST NOM 117 SEPRO TCF UL |
Relative Humidity | 0-95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
Standards | EN/IEC 60947-4-2 |
OTHER | |
Poles Description | soft starter |
[Us] Rated Supply Voltage | 208...690 V - 15...10 % |