Input Interface Module - 17.5 Mm - Electromechanical - 230/240 V AC - 1 C/O.

Schneider
SKU
SE_ABR1E311M
Model
ABR1E311M

Obsolete

Short description of ABR1E311M

Electromechanical and solid state interfaces for discrete signals
Obsolete
*All information are subjected to changes without prior notice.
range of product : Interface for discrete signals
-  product or component type : Electromechanical input interface module
-  contacts type and composition : 1 C/O
-  [Uc] control circuit voltage : 230...240 V
-  control circuit type : AC
-  control circuit frequency : 50/60 Hz
-  width pitch dimension : 17.5 mm
-  maximum [In] rated current : 7 mA AC
-  reverse polarity protection : With
-  short-circuit protection : 16 A external fuse gF (Ik
-  [Ith] conventional free air thermal current : 2 A conforming to IEC 60947-1
-  local signalling : Green mechanical indicator for position of contacts and 1 green LED control signal state
MAIN SPECIFICATIONS
Contacts Type And Composition1 C/O
Discrete Input Number1 C/O
Product Or Component Typeelectromechanical input interface module
Range Of Productinterface for discrete signals
[Ie] Rated Operational Current1 A AC-13 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
1 A AC-14 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
1 A AC-15 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
1 A DC-13 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
2 A AC-12 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
2 A DC-12 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
[Uc] Control Circuit Voltage230...240 V
[Ue] Rated Operational Voltage<= 125 V DC conforming to IEC 60947-5-1
<= 230 V AC conforming to IEC 60947-5-1
Control Circuit Frequency50/60 Hz
Control Circuit TypeAC
Maximum [In] Rated Current7 mA AC
Mounting Supportasymmetrical DIN rail
combination rail
symmetrical DIN rail
Range NameZelio Interface
Short-circuit Protection16 A external fuse gF (Ik <= 2.5 kA AC and Ik <= 100 A DC)
16 A external fuse gG (Ik <= 2.5 kA AC and Ik <= 100 A DC)
Width Pitch Dimension17.5 mm
COMPLEMENTARY
Communication Network Type<= 125 V DC conforming to IEC 60947-5-1
<= 230 V AC conforming to IEC 60947-5-1
Cable Cross Section0.27-2.5 mm², 2 wires rigid
0.27-4 mm², 1 wire rigid
0.34-2.5 mm², 1 or 2 wires flexible with cable end
0.6-2.5 mm², 1 or 2 wires flexible without cable end
Connections - Terminalsscrew clamp terminal
Contact Bounce Time<= 3 ms
Control Circuit Voltage Limits264 V energization threshold: 170 V
Drop-out Voltage68 V
Electrical Reliability<= 0.00000001
Flame RetardanceV0 conforming to UL 94
Housing Colourgrey
Immunity To Microbreaks5 ms
Local Signallinggreen mechanical indicator for position of contacts and 1 green LED control signal state
Maximum Power Dissipation In W1.5 W
Maximum Switching Voltage125 V DC
252 V AC
Mechanical Durability10000000 cycles
Minimum Holding Current2 mA AC
Minimum Switching Current3 mA
Minimum Switching Voltage17 V
Net Weight0.095 kg
Network Frequency50/60 Hz
Operating Positionany position
Operating Rate In Hz0.5 Hz at Ie
6 Hz at no-load
Operating Time<= 12 ms between de-energisation of coil and closing of NC contact
<= 12 ms between de-energisation of coil and closing of NO contact
<= 12 ms between energisation of coil and closing of NC contact
<= 12 ms between energisation of coil and closing of NO contact
Reverse Polarity Protectionwith
[Ith] Conventional Free Air Thermal Current2 A conforming to IEC 60947-1
[Ui] Rated Insulation Voltage250 V conforming to IEC 60947-1
250 V conforming to VDE 0110 group C
ENVIRONMENT
Ambient Air Temperature For Operation-20-60 °C at Un
-5-40 °C unrestricted operation
Ambient Air Temperature For Storage-40-70 °C
Dielectric Strength1500 V between independent contacts
2500 V between wired interface and earth
4000 V between coil circuit and contact circuits
Electromagnetic Compatibility1.2/50 ms shock waves immunity test conforming to IEC 255-4
electrostatic discharge immunity test, level 3 8 kV conforming to IEC 61000-4-2
rapid transients immunity test on input/output 1 kV conforming to IEC 61000-4-4
rapid transients immunity test on power supply 2 kV conforming to IEC 61000-4-4
Fire Resistance850 °C conforming to IEC 60695-2-1
Installation CategoryII conforming to IEC 60947-1
IP Degree Of ProtectionIP20 conforming to IEC 60529
Operating Altitude<= 3000 m
Pollution Degree3 conforming to IEC 60947-5-1
Product CertificationsBV
CSA
DNV
LROS (Lloyds register of shipping)
UL
Protective TreatmentTC
Shock Resistance50 gn for 11 ms conforming to IEC 60068-2-27
StandardsIEC 60947-5-1
Vibration Resistance6 gn conforming to IEC 60068-2-6 (f = 10-55 Hz)
OTHER
Poles Descriptionelectromechanical input interface module
[Us] Rated Supply Voltageinterface for discrete signals