Singapore GST will increase from 8% to 9%

(Effective from Jan 1, 2024)

Electgo: Your trusted Source for Electrical Components in Singapore

An Authorized Supplier Offering a Comprehensive Range of Electrical Component Categories

Loading...

Regulated Power Supply, 100-240V AC, 24V 20 A, Single Phase, Optimized

Schneider
SKU
SE_ABLS1A24200
Model
ABLS1A24200
SGD $441.13

Short description of ABLS1A24200

POWER SUPPLY 24V 20A 1PH OPTIMIZED
Country of Origin
Thailand
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
MAIN SPECIFICATIONS
Physical Interface24 V DC
Power Supply Output Current20 A
Pressure Sensor Size20 A
Pressure Sensor Type480 W
Product Or Component Typepower supply
Range Of ProductModicon Power Supply
Rated Power In W480 W
Enclosure Materialaluminium
Mounting Supportdouble-profile DIN rail
top hat type TH35-15 rail conforming to IEC 60715
top hat type TH35-7.5 rail conforming to IEC 60715
Power Supply Typeregulated switch mode
Range NamePhaseo ABL7, ABL8
COMPLEMENTARY
Input Voltage100...240 V AC 2 phases
100...240 V AC single phase
140...340 V DC
Output Voltage24 V DC
Connections - Terminalsscrew connection: 0.5...2.5 mm², (AWG 20...AWG 14) with wire end ferrule for output
screw connection: 0.5...4 mm², (AWG 20...AWG 12) without wire end ferrule for output
screw connection: 0.75...4 mm², (AWG 18...AWG 12) with wire end ferrule for input
screw connection: 0.75...4 mm², (AWG 18...AWG 12) without wire end ferrule for input
Current Consumption< 2.7 A 230 V AC
< 5 A 140 V DC
< 5.4 A 115 V AC
Depth128.5 mm
Earthing SystemIT
TN
TT
Efficiency85 % at 115 V AC
88 % at 230 V AC
Height123.6 mm
Holding Time> 20 ms 115 V AC
> 20 ms 230 V AC
Input Protection Typeexternal protection (recommended) 13 A Curve C
external protection (recommended) 16 A Curve B
external protection (recommended) 20 A Curve C
integrated fuse (not interchangeable) 10 A
Input Voltage Limits120...375 V DC (without temperature derating)
85...264 V AC (without temperature derating)
85…120 V DC
85…120 V DC (with temperature derating)
Inrush Current45.0 A at 115 V
90.0 A at 230 V
Line And Load Regulation< 0.5 % network 0 to 100 % load at 25 °C
< 1 % network full voltage range in line at 25 °C
Load Capacitance8000 µF
Maximum Leakage Current1 mA 240 V AC
Meantime Between Failure [MTBF]700000 h at 25 °C, full load conforming to SR 332
Net Weight1.25 kg
Network Frequency Limits50-60 Hz
Output Couplingparallel
serial
Output Protection Typeagainst over temperature, protection technology: manual reset
against overload and short-circuits, protection technology: automatic reset
against overvoltage, protection technology: manual reset
Output Voltage Limits22...28 V
Power Dissipation In W60 W
Power Factor0.95 at 115 V AC
0.95 at 230 V AC
Residual Ripple< 120 mV
Response Time< 1.5 s
Service Life10 year(s)
Status LED1 LED (green)output voltage
SupplySELV conforming to EN/IEC 60204-1
SELV conforming to EN/IEC 60950-1
SELV conforming to IEC 60364-4-41
Variant Optionoptimized
Width85.5 mm
ENVIRONMENT
Ambient Air Temperature For Operation-20-40 °C without derating mounting position A 115V AC < 2000 m
-20-50 °C without derating mounting position A 230V AC < 2000 m
40-70 °C with current derating of 1.67 % per °C mounting position A 115V AC < 2000 m
50-70 °C with current derating of 2.5 % per °C mounting position A 230V AC < 2000 m
Dielectric Strength3000 V AC with input to output
Electrical Shock Protection Classclass I
Electromagnetic Compatibilityconducted disturbance emission conforming to EN 55016-1-2
conducted disturbance emission conforming to EN 55016-2-1
disturbing field emission conforming to EN 55016-2-3
immunity to conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
immunity to conducted RF disturbances - test level: 10 V/m (80 MHz...2 GHz) conforming to EN/IEC 61000-4-3
immunity to conducted RF disturbances - test level: 3 V/m (2.7...6 GHz) conforming to EN/IEC 61000-4-3
immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to EN/IEC 61000-4-3
immunity to electrostatic discharge - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
immunity to electrostatic discharge - test level: 9 kV (air discharge) conforming to EN/IEC 61000-4-2
immunity to fast transients - test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4
immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8
immunity to voltage dips conforming to EN/IEC 61000-4-11
limits for harmonic current emissions conforming to EN 61000-3-2
surge immunity test - test level: 1.5 kV (between phases) conforming to EN/IEC 61000-4-5
surge immunity test - test level: 3 kV (between power supply and earth) conforming to EN/IEC 61000-4-5
Electromagnetic Emissionconducted emissions conforming to EN 61000-6-3
radiated emissions conforming to EN 61000-6-4
Environmental Characteristic3M4 conforming to IEC 60721-3-3
IP Degree Of ProtectionIP20
Operating Altitude< 5000 m
Pollution Degree2
Product CertificationsCB Scheme
CE
cUL listed
cUL recognized
EAC
KC
RCM
Shock Resistance100 m/s² for 11 ms
StandardsCSA C22.2 No 61010-1
CSA C22.2 No 61010-2-201
CSA C22.2 No 62368-1
EN 61000-3-2
EN 61000-3-3
EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
EN 61010-2-201
EN 62368-1
EN/IEC 61010-1
EN/IEC 61204-3
EN/IEC 62368-1
UL 61010-1
UL 61010-2-201
UL 62368-1
Vibration Resistance10 m/s² (f= 9-200 Hz) conforming to IEC 60068-2-6
3 mm (f= 2-9 Hz) conforming to IEC 60068-2-6
OTHER
Poles Descriptionpower supply
[Us] Rated Supply VoltageModicon Power Supply
Write Your Own Review
You're reviewing:Regulated Power Supply, 100-240V AC, 24V 20 A, Single Phase, Optimized
Your Rating