Energy Sensor, PowerTag PhaseNeutral 63A 1P+N Bottom Position for RCBO

Schneider
SKU
SE_A9MEM1563
Model
A9MEM1563
SGD $235.82

Short description of A9MEM1563

PowerTag Energy P63 1PN Bottom RCBO 18mm
Country of Origin
France
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 14 To 16 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
PowerTag Acti9 PhaseNeutral 1P+N Bottom position Max 63A Energy Sensor for RCBO.
Label : PowerTag
- range : Acti9-saturation current : 130 A
- product specific application : load monitoring,cost allocation,overload alarm,circuit monitoring
- Concentrator compatibility : Acti9 Smartlink SI B,Acti9 Smartlink SI D,Acti9 Smartlink EL D
- market segment : 
- range compatibility : 
- communication port protocol : 
- accuracy class : 
- mounting location : bottom
- mounting support : on circuit breaker
- fixing mode : 
- product name : PowerTag A9 P63-connection pitch : 
- product destination : 
- type of measurement : active power,power factor,active energy,current,voltage
- product or component type : energy sensor
- height : -poles description : 1P + N
- max current : 63 A
- [Ib] basic current : 10 A
- starting current : 40 mA
- Range Presentation : When your load is not working, do you want to know if it comes from the load or from the circuit breaker? PowerTag® not only measures energy and power in real time, it also monitors your assets and immediately alerts your smartphone in the event of downtime! Just 'tag' your circuit breakers anytime, anywhere, and stay fully connected to the vital assets that make your business run smoothly.
Main features : 
1. Compacity  :  Integrated into the Acti9 Smartlink system, PowerTag®
-  which can also be installed in existing panels, is the smallest wireless energy sensor on the market, designed to enhance the monitoring of your electrical assets. Due to its compact size, PowerTag can easily fit any existing panel, and takes up no space on the DIN rail.
2. Simplicity  :  Acti 9 Smartlink concentrates the data that is received wirelessly from PowerTag and simplifies the connectivity of individual breakers to a Building Management System (BMS), providing building owners and facility managers with precise, powerful, real-time data, to improve the health of their facility's strategic assets.
3. Wireless  :  PowerTag is installed with no additional wires
-  cutting installation time to just a few minutes, even for existing panel installations.
4. No more need for local display panel  :  visualize in real-time on your Smartphone or PC, via wi
- fi or your company network, thanks to the specially designed Acti 9 Smartlink embedded web pages.
-  Fits into existing panels  :  up to 20 PowerTag units can be installed using Acti Smartlink.
-  Provides real-time electrical load data and e-mail alerts in the event of potential issues, via Acti 9 Smartlink.
-  Easy to install and commission  :  using Acti 9 Smart Test free software.
-  Total and partial energy, power, load
- balancing by phase, current by phase, voltage by phase.
- Range Benefits : 
-  Reduced cabling errors
-  saves space
-  High density metering
-  No need to replace panel – saves money
-  Real-time decisions – reduce downtime
-  Installation time is reduced by 90% – efficient and simple
-  Saves space – easy to install
-  saves costs
-  Real-time data monitoring and management via embedded web pages and e-mail alerts
-  Smart/connected breakers with no change in the switchboard footprint
- Range Application Presentation : A wide range of buildings
-  PowerTag can be installed in new buildings or in existing panels.
MAIN SPECIFICATIONS
Control Type1P + N
Product Or Component Typeenergy sensor
[Ue] Rated Operational Voltage200...240 V AC, +/- 20 %
Concentrator CompatibilityActi9 PowerTag Link
Acti9 PowerTag Link C
Acti9 PowerTag Link HD
Acti9 Smartlink SI B
Acti9 Smartlink SI D
EcoStruxure Panel Server Universal
PrismaSet Active
Wiser IP module
EAN133606481380425
Event Managementvoltage loss with measured current at voltage loss
Mounting Supporton circuit breaker
Product Specific Applicationcircuit monitoring
cost allocation
energy management
load monitoring
overload alarm
RangePowerLogic
Range Compatibility Acti 9 iKQE RCBO
Acti9 iC60 iC60H RCBO
Acti9 iC60 iC60H2 RCBO
Range NamePowerTag
Starting Current40 mA
Transmission Support Mediumradio frequency 2.4-2.4835 GHz conforming to IEEE 802.15.4
Type Of Measurementactive energy
active power
current
power factor
voltage
[Ib] Basic Current10 A
COMPLEMENTARY
Communication Network Type200...240 V AC, +/- 20 %
Product NamePowerTag A9 P63
Accuracy Classclass 0.5 voltage conforming to IEC 61557-12
class 1 active energy conforming to IEC 61557-12
class 1 active power conforming to IEC 61557-12
class 1 current conforming to IEC 61557-12
class 1 power factor conforming to IEC 61557-12
Cable Cross Section1 rigid cable 1.5-16 mm²
1 stranded cable 1.5-16 mm²
2 rigid cable 1.5-2.5 mm²
2 stranded cable 1.5-2.5 mm²
Colourwhite (RAL 9003)
Compatibility CodePowerTag A9 F63
Connection Pitch9 mm Ph/N
Depthbase unit: 28 mm
sensor element: 44.5 mm
Electrical Connectionconnector tooth
Emission Power10 mW
Form FactorphaseNeutral
Heightbase unit: 8 mm
sensor element: 20 mm
Market Segmentbuildings: breaker voltage monitoring
buildings: cost allocation
buildings: overload alarm
Max Current63 A
Mounting Locationbottom
Mounting Modeby screws (terminals)
Net Weight18 g
Network Frequency50 Hz
60 Hz
Power Consumption In VA1 VA
Product Destinationswitchboard
Saturation Current130 A
Widthbase unit: 18 mm
sensor element: 18 mm
ENVIRONMENT
Ambient Air Temperature For Operation-25-60 °C
Ambient Air Temperature For Storage-40-85 °C
Directives2014/53/EU - radio equipment directive
Environmental Characteristicdustproof class 3S3 conforming to IEC 60721-3-3
indoor use
salt mist class 3C2 conforming to IEC 60721-3-3
IK Degree Of ProtectionIK05
IP Degree Of ProtectionIP20 conforming to IEC 60529
Measurement Categorycategory III conforming to IEC 61010-2-030
Operating Altitude0...2000 m
Overvoltage CategoryIII conforming to IEC 61010-1
Pollution Degree3
Quality LabelsCE
Relative Humidity0-95 % at 45-45 °C conforming to IEC 60721-3-3
StandardsETSI EN 300 328
IEC 61010-1
IEC 61010-2-030
IEC 61326-1
IEC 61557-12
Vibration Resistance3M4 conforming to IEC 60721-3-3
OTHER
Poles Description1P + N