Singapore GST will increase from 8% to 9%

(Effective from Jan 1, 2024)

Electgo: Your trusted Source for Electrical Components in Singapore

An Authorized Supplier Offering a Comprehensive Range of Electrical Component Categories

Loading...

Miniature Circuit-breaker, Acti9 IC60N, 2P, 13 A, D Curve, 6000 A (IEC 60898-1), 10 KA (IEC 60947-2).

Schneider
SKU
SE_A9F75213
Model
A9F75213

Obsolete

Short description of A9F75213

Miniature Circuit Breakers up to 63 A
Obsolete
*All information are subjected to changes without prior notice.
device application : Distribution
-  range : Acti 9
-  product name : Acti 9 iC60
-  product or component type : Miniature circuit-breaker
-  device short name : IC60N
-  poles description : 2P
-  number of protected poles : 2
-  [In] rated current : 13 A
-  network type : DCAC
-  trip unit technology : Thermal
- magnetic
-  curve code : D
-  breaking capacity : 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-136 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-210 kA Icu at - utilisation category : Category A conforming to EN 60947-2Category A conforming to IEC 60947-2
-  suitability for isolation : Yes conforming to EN 60898-1Yes conforming to EN 60947-2Yes conforming to IEC 60898-1Yes conforming to IEC 60947-2
-  standards : EN 60898-1IEC 60947-2EN 60947-2IEC 60898-1
MAIN SPECIFICATIONS
Breaking Capacity10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking Capacity CodeN
Contacts Type And Composition13 A
Control Typetoggle
Product Or Component Typeminiature circuit-breaker
Range Of ProductiC60
[Ie] Rated Operational Currenttoggle
[Ue] Rated Operational Voltage12...133 V AC 50/60 Hz
220...240 V AC 50/60 Hz
380...415 V AC 50/60 Hz
400 V AC 50/60 Hz
440 V AC 50/60 Hz
72...125 V DC
Curve CodeD
Device Short NameIC60N
Mounting SupportDIN rail
Network TypeAC
DC
Number Of Protected Poles2
RangeActi 9
Range NameActi 9 iC60
Suitability For Isolationyes conforming to EN 60898-1
yes conforming to EN 60947-2
yes conforming to IEC 60898-1
yes conforming to IEC 60947-2
Trip Unit Technologythermal-magnetic
Utilisation Categorycategory A conforming to EN 60947-2
category A conforming to IEC 60947-2
COMPLEMENTARY
Communication Network Type12...133 V AC 50/60 Hz
220...240 V AC 50/60 Hz
380...415 V AC 50/60 Hz
400 V AC 50/60 Hz
440 V AC 50/60 Hz
72...125 V DC
Current Transformer TypeN
Interlocked Device10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Product NameActi9 iC60
[Ics] Rated Service Breaking Capacity10 kA 100 % conforming to EN 60947-2 - 72...125 V DC
10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC
15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz
4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz
7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
[In] Rated Current13 A
9 Mm Pitches4
Colourwhite
Comb Busbar And Distribution Block Compatibilitytop or bottom: YES
Compatibility CodeiC60
Connections - Terminalssingle terminal (top or bottom) 1-16 mm² flexible
single terminal (top or bottom) 1-25 mm² rigid
Contact Position Indicatoryes
Depth78.5 mm
Device Applicationdistribution
Earth-leakage Protectionseparate block
Electrical Durability10000 cycles
Height85 mm
Local Signallingtrip indicator
Magnetic Tripping Limit12 x In +/- 20 %
Market Segmentsmall commercial
Mechanical Durability20000 cycles
Mounting Modefixed
Net Weight0.25 kg
Network Frequency50/60 Hz
Tightening Torque2-2 N.m top or bottom
Width36 mm
Wire Stripping Length14 mm for top or bottom connection
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
[Ui] Rated Insulation Voltage500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
ENVIRONMENT
Ambient Air Temperature For Operation-35-70 °C
Ambient Air Temperature For Storage-40-85 °C
IP Degree Of ProtectionIP20 conforming to EN 60529
IP20 conforming to IEC 60529
Operating Altitude0...2000 m
Overvoltage CategoryIV
Pollution Degree3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Relative Humidity95-95 % at 55-55 °C
StandardsEN 60898-1
EN 60947-2
IEC 60898-1
IEC 60947-2
Tropicalisation2 conforming to IEC 60068-1
OTHER
Poles Description2P
[Us] Rated Supply VoltageiC60