Acti 9 - RCA Remote Ctrl Aux for IC60 3P-4P

Schneider
SKU
SE_A9C70114
Model
A9C70114
SGD $340.33

Short description of A9C70114

RCA REMOTE CONTROL AUXILIARY FOR IC60 3-
Country of Origin
Spain
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 13 To 15 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
Acti 9
-  RCA remote ctrl aux for iC60 3P
- 4P.
Label :  Acti 9 iC60
-  range of product :  iC60
-  range :  Acti 9
-  product or component type :  remote control auxiliary
-  device short name :  RCA iC60
-  signal contacts composition :  1 OF volt
- free contacts
-  signalling circuit voltage :  N/A
-  Range Presentation :  With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
-  VisiSafe  :  for safe operation and maintenance work on circuits.
-  Class-2 insulation  :  continuous safety for operators and unqualified personnel.
-  VisiTrip  :  detects faulty Miniature Circuit
- Breaker outgoers quickly and reduces intervention time.
-  Add-on fully immune earth leakage protection devices  :  better continuity of service, especially in polluted environments and networks.
-  Nominal current :  1 to 63 A
-  Large choice of breaking capacities up to 100 kA and tripping curves :  B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
-  Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
-  Suitable for isolation in accordance with industrial standard IEC 60947
-  Operating voltage :  up to 440 V AC, insulation voltage :  500 V
-  Optional add-on earth leakage modules :  iC60 Vigi,
-  Optional auxiliaries :  indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
-  For more information click here
-  Range Benefits : 
-  The new reference in final distribution,
-  Absolute safety of circuit protection with VisiSafe,
-  Greater continuity of service with VisiTrip,
-  Simple to choose with meaningful part numbers,
-  Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
-  Environmentally friendly with 100% recyclable & recoverable materials.
-  Range Application Presentation :  Low-voltage final distribution
-  Protection of electrical circuits in all industrial and commercial buildings,
-  All applications, especially in polluted environments and networks,
-  Motor circuit protection,
-  DC current circuit protection.
MAIN SPECIFICATIONS
Analogue Input Number230 V AC 50/60 Hz
Control Typeremote control impulse and maintained 230 V AC 50/60 Hz
Product Or Component Typeremote control auxiliary
Range Of ProductiC60
[Ie] Rated Operational Currentremote control impulse and maintained 230 V AC 50/60 Hz
Device Short NameRCA iC60
EAN133606480097959
Mounting SupportDIN rail
RangeActi 9
Range Compatibility Acti9 iC60
Acti9 iC65
iMDU voltage adaptor
Range NameActi 9 iC60
Signal Contacts Composition1 OF volt-free contacts
Signalling Circuit Voltagevolt-free contact 24...230 V 0.01…1 A AC
COMPLEMENTARY
9 Mm Pitches7
Colourwhite
Comb Busbar And Distribution Block CompatibilityNO
Compatibility CodeRCA iC60
Connections - Terminalsinput: tunnel type terminals 1 cable(s) 0.5-10 mm² rigid without cable end
input: tunnel type terminals 1 cable(s) 0.5-4 mm² flexible with cable end
input: tunnel type terminals 1 cable(s) 0.5-6 mm² flexible without cable end
input: tunnel type terminals 2 cable(s) 0.5-2.5 mm² flexible with cable end
input: tunnel type terminals 2 cable(s) 0.5-2.5 mm² flexible without cable end
input: tunnel type terminals 2 cable(s) 0.5-2.5 mm² rigid without cable end
output: tunnel type terminals 1 cable(s) 0.5-1.5 mm² flexible with cable end
output: tunnel type terminals 1 cable(s) 0.5-2.5 mm² flexible without cable end
output: tunnel type terminals 1 cable(s) 0.5-2.5 mm² rigid without cable end
output: tunnel type terminals 2 cable(s) 0.5-1.5 mm² flexible with cable end
output: tunnel type terminals 2 cable(s) 0.5-1.5 mm² flexible without cable end
output: tunnel type terminals 2 cable(s) 0.5-1.5 mm² rigid without cable end
power supply: tunnel type terminals 1 cable(s) 0.5-10 mm² rigid without cable end
power supply: tunnel type terminals 1 cable(s) 0.5-4 mm² flexible with cable end
power supply: tunnel type terminals 1 cable(s) 0.5-6 mm² flexible without cable end
power supply: tunnel type terminals 2 cable(s) 0.5-2.5 mm² flexible with cable end
power supply: tunnel type terminals 2 cable(s) 0.5-2.5 mm² flexible without cable end
power supply: tunnel type terminals 2 cable(s) 0.5-2.5 mm² rigid without cable end
Depth75.5 mm
Electrical Durability10000 cycles
Height93 mm
Impulse Duration>= 200 ms control circuit
Input Current5 mA impulse
5 mA maintained
Local Signallingflashing green LED: ready to operate
flashing orange LED: not operational
Locking Options Descriptionpadlocking in OFF position
Market Segmentresidential
small commercial
Mechanical Durability10000 cycles
Mounting Modefixed
Net Weight430 g
Power Consumption In W1 W
Product Compatibility iMDU
3P or 4P iC60
3P or 4P iC65
Provision For Padlockingpadlockable
Response Time< 500 ms
Tightening Torqueauxiliary input: 1-1 N.m
auxiliary output: 0.7-0.7 N.m
auxiliary supply: 1-1 N.m
Value Of Settingauto: remote control authorized
mode A: reclosing authorized after tripping
mode B: reclosing inhibited after tripping
off: remote control inhibited
Width63 mm
Wire Stripping Lengthinput: 10 mm for bottom connection
output: 8 mm for top connection
power supply: 10 mm for bottom connection
[Uimp] Rated Impulse Withstand Voltage6 kV
[Ui] Rated Insulation Voltage400 V
ENVIRONMENT
Ambient Air Temperature For Operation-25-60 °C
Ambient Air Temperature For Storage-40-70 °C
IP Degree Of ProtectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Overvoltage CategoryII
Pollution Degree3 conforming to IEC 60947
Relative Humidity93-93 % at 40-40 °C
Tropicalisation2
OTHER
Poles Descriptionremote control auxiliary
[Us] Rated Supply Voltage230 V AC 50/60 Hz