On-delay Timing Relay - 1 S..100 H - 24..240 V AC/DC - Solid State Output
Schneider
SKU
SE_RE17LAMW
Model
RE17LAMW
SGD $52.33
Short description of RE17LAMW
ON DELAY TIMER 24 240 VAC
Country of Origin
Indonesia
on-delay timing relay
-  1 s..100 h
-  24..240 V AC/DC
-  solid state output.
Label :  Zelio Time
-  range of product :  Zelio Time
-  nominal output current :  0.7 A
-  product or component type :  modular timing relay
-  discrete output type :  solid state
-  width :  17.5 mm
-  component name :  RE17L
-  time delay type :  A
-  time delay range :  1...10 s,10...100 h,6...60 s,0.1...1 s,1...10 min,6...60 min,1...10 h
-  Range Presentation : 
-  Multifunction
-  Relay or solid state output
-  Wide voltage range from 24 to 240 V
-  Single timing range or multi-range from 50 ms to 300 hrs
-  Conformity to IEC 61812-1, EN 61812-1 standards
-  Range Benefits :  Timer relays that are simply ingeniousAccurate adjustments and legible wiring diagrams on the side of Zelio Time relays make them simple, fast, and easy to set up. And with a choice in the number of outputs and either screw or spring connection terminals, Zelio Time is the flexible, high performance solution.
-  Range Application Presentation : 
-  Industry and building :  simple machine control panels, process control.
-  Applications requiring frequent and simple adjustment of cycle times.
-  1 s..100 h
-  24..240 V AC/DC
-  solid state output.
Label :  Zelio Time
-  range of product :  Zelio Time
-  nominal output current :  0.7 A
-  product or component type :  modular timing relay
-  discrete output type :  solid state
-  width :  17.5 mm
-  component name :  RE17L
-  time delay type :  A
-  time delay range :  1...10 s,10...100 h,6...60 s,0.1...1 s,1...10 min,6...60 min,1...10 h
-  Range Presentation : 
-  Multifunction
-  Relay or solid state output
-  Wide voltage range from 24 to 240 V
-  Single timing range or multi-range from 50 ms to 300 hrs
-  Conformity to IEC 61812-1, EN 61812-1 standards
-  Range Benefits :  Timer relays that are simply ingeniousAccurate adjustments and legible wiring diagrams on the side of Zelio Time relays make them simple, fast, and easy to set up. And with a choice in the number of outputs and either screw or spring connection terminals, Zelio Time is the flexible, high performance solution.
-  Range Application Presentation : 
-  Industry and building :  simple machine control panels, process control.
-  Applications requiring frequent and simple adjustment of cycle times.
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 24...240 V AC/DC 50/60 Hz |
Breaking Capacity | 0.5 A AC/DC conforming to UL 0.7 A AC/DC at 20 °C |
Contacts Type And Composition | 0.7 A |
Control Type | selector switch front panel |
Discrete Output Type | solid state |
Product Or Component Type | single function relay |
Range Of Product | Harmony Timer Relays |
Thread Type | 0.1...1 s 1...10 h 1...10 min 1...10 s 10...100 h 6...60 min 6...60 s |
[Ie] Rated Operational Current | selector switch front panel |
[Uc] Control Circuit Voltage | 24...240 V |
Component Name | RE17L |
EAN13 | 3606480552625 |
Mounting Support | 35 mm DIN rail conforming to EN/IEC 60715 |
Range Name | Zelio Time |
Time Delay Type | A power on-delay |
COMPLEMENTARY | |
Interlocked Device | 0.5 A AC/DC conforming to UL 0.7 A AC/DC at 20 °C |
Product Name | solid state |
Time Delay Range | 0.1...1 s 1...10 h 1...10 min 1...10 s 10...100 h 6...60 min 6...60 s |
[Ics] Rated Service Breaking Capacity | solid state |
[In] Rated Current | 0.7 A |
Compatibility Code | RE17 |
Connections - Terminals | screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end screw connectors |
Creepage Distance | 4 kV/3 conforming to IEC 60664-1 |
Electrical Durability | 100000000 cycles |
Functionality | on-delay timing |
Housing Material | self-extinguishing |
Immunity To Microbreaks | 20 ms |
Impulse Duration | 0.05 s typical |
Insulation Resistance | 100 MOhm at 500 V DC conforming to IEC 60664-1 |
Marking | CE |
Maximum Delay Response | 100 ms |
Maximum Leakage Current | 5 mA |
Maximum Output Current | 20 A |
Maximum Power Consumption In W | 1.5 W at 240 V DC |
Maximum Switching Voltage | 250 V AC/DC |
Maximum Voltage Drop | <4 V 3-wire <8 V 2-wire |
Minimum Switching Current | 10 mA |
Mounting Position | any position in relation to normal vertical mounting plane |
Net Weight | 0.068 kg |
Nominal Output Current | 0.7 A |
On-load Factor | 100 % |
Operating Rate In Hz | 10 Hz |
Output Type | solid state |
Power Consumption In VA | 0-3 VA at 240 V AC |
Repeat Accuracy | +/- 0.5 % conforming to IEC 61812-1 |
Reset Time | 350 ms on de-energisation typical |
Safety Reliability Data | B10d = 320000 MTTFd = 353.8 years |
Setting Accuracy Of Time Delay | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 |
Supply Frequency | 50...60 Hz +/- 5 % |
Temperature Drift | +/- 0.05 %/°C |
Tightening Torque | 0.6-1 N.m conforming to IEC 60947-1 |
Voltage Drift | +/- 0.2 %/V |
Voltage Range | 0.85...1.1 Us |
Width | 17.5 mm |
[Uimp] Rated Impulse Withstand Voltage | 5 kV during 1.2/50 µs |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -20-60 °C |
Ambient Air Temperature For Storage | -30-60 °C |
Derating Factor | 5 mA/°C |
Dielectric Strength | 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1 |
Electromagnetic Compatibility | 1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5 conducted and radiated emissions: , class B, conforming to EN 55022 conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6 electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4 electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4 electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2 electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2 susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3 voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11 voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11 |
IP Degree Of Protection | IP20 (terminal block) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 |
Product Certifications | CSA cULus GL |
Relative Humidity | 93-93 % without condensation conforming to IEC 60068-2-30 |
Shock Resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
Standards | 2004/108/EC 2006/95/EC EN 61000-6-1 EN 61000-6-2 EN 61000-6-3 EN 61000-6-4 IEC 61812-1 |
Vibration Resistance | 20 m/s² (f= 10-150 Hz) conforming to IEC 60068-2-6 |
OTHER | |
Poles Description | single function relay |
[Us] Rated Supply Voltage | 24...240 V AC/DC 50/60 Hz |
Write Your Own Review