Multi9 - C60H-DC - MCB - 1P - 16 A - C Curve - 250 V DC - 10 KA.

Schneider
SKU
SE_M9U21116
Model
M9U21116
SGD $84.40

Short description of M9U21116

Wide range of Miniature Circuit Breakers for Original Equipment Manufacturers (OEMs) and control panel builders
Country of Origin
China
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 4 To 6 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
range : Multi 9
-  product name : Multi 9 C60H
- DC
-  product or component type : Miniature circuit-breaker
-  device short name : C60H
- DC
-  device application : Distribution
-  poles description : 1P
-  number of protected poles : 1
-  [In] rated current : 16 A at 25 °C conforming to EN/IEC 60947-2
-  network type : DC
-  trip unit technology : Thermal
- magnetic
-  curve code : C
-  breaking capacity : 10 kA Icu at 220 V DC conforming to EN/IEC 60947-26 kA Icu at 250 V DC conforming to EN/IEC 60947-220 kA Icu at 110 V DC conforming to EN/IEC 60947-25 kA AIR at 12...250 V DC conforming to UL 107710 kA Icu at 220 V DC conforming to GB 14048.26 kA Icu at 250 V DC conforming to GB 14048.220 kA Icu at 110 V DC conforming to GB 14048.2
-  utilisation category : Category A conforming to EN/IEC 60947-2
-  suitability for isolation : Yes conforming to EN/IEC 60947-2
-  standards : EN/IEC 60947-2GB 14048.2UL 1077
-  product certifications : IECCCCUR
MAIN SPECIFICATIONS
Breaking Capacity10 kA Icu at 220 V DC conforming to EN/IEC 60947-2
10 kA Icu at 220 V DC conforming to GB 14048.2
20 kA Icu at 110 V DC conforming to EN/IEC 60947-2
20 kA Icu at 110 V DC conforming to GB 14048.2
5 kA AIR at 12...250 V DC conforming to UL 1077
6 kA Icu at 250 V DC conforming to EN/IEC 60947-2
6 kA Icu at 250 V DC conforming to GB 14048.2
Breaking Capacity CodeH
Contacts Type And Composition16 A at 25 °C conforming to EN/IEC 60947-2
Control Typetoggle
Product Or Component Typeminiature circuit-breaker
Range Of ProductMulti 9
[Ie] Rated Operational Currenttoggle
[Ue] Rated Operational Voltage110 V DC
220 V DC
250 V DC
Curve CodeC
Device Short NameC60H-DC
Mounting SupportDIN rail
Network TypeDC
Number Of Protected Poles1
RangeMulti 9
Range NameMulti 9
Suitability For Isolationyes conforming to EN/IEC 60947-2
Trip Unit Technologythermal-magnetic
Utilisation Categorycategory A conforming to EN/IEC 60947-2
COMPLEMENTARY
Communication Network Type110 V DC
220 V DC
250 V DC
Current Transformer TypeH
Interlocked Device10 kA Icu at 220 V DC conforming to EN/IEC 60947-2
10 kA Icu at 220 V DC conforming to GB 14048.2
20 kA Icu at 110 V DC conforming to EN/IEC 60947-2
20 kA Icu at 110 V DC conforming to GB 14048.2
5 kA AIR at 12...250 V DC conforming to UL 1077
6 kA Icu at 250 V DC conforming to EN/IEC 60947-2
6 kA Icu at 250 V DC conforming to GB 14048.2
Product NameMulti 9 C60H-DC
[Ics] Rated Service Breaking Capacity15 kA 75 % conforming to EN/IEC 60947-2 - 110 V DC
15 kA 75 % conforming to GB 14048.2 - 110 V DC
4.5 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC
4.5 kA 75 % conforming to GB 14048.2 - 250 V DC
7.5 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC
7.5 kA 75 % conforming to GB 14048.2 - 220 V DC
[In] Rated Current16 A at 25 °C conforming to EN/IEC 60947-2
9 Mm Pitches2
Colourgrey
Connections - Terminalstunnel type terminal (top or bottom) - 2 cable(s) 1-10 mm² (AWG 18...AWG 8) - flexible
tunnel type terminal (top or bottom) - 2 cable(s) 1-10 mm² (AWG 18...AWG 8) - flexible with ferrule
tunnel type terminal (top or bottom) - 2 cable(s) 1-10 mm² (AWG 18...AWG 8) - rigid stranded
tunnel type terminal (top or bottom) - 3 cable(s) 1-1 mm² (AWG 18) - flexible stranded
tunnel type terminal (top or bottom)1-16 mm² (AWG 18...AWG 6) - flexible
tunnel type terminal (top or bottom)1-16 mm² (AWG 18...AWG 6) - flexible with ferrule
tunnel type terminal (top or bottom)1-25 mm² (AWG 18...AWG 4) - rigid stranded
Contact Position Indicatoryes
Depth73 mm
Device Applicationdistribution
Earth-leakage Protectionwithout
Electrical Durability3000 cycles 250 V DC L/R = 2 ms
6000 cycles 250 V DC
Height81 mm
Local SignallingON/OFF indication
Magnetic Tripping Limit7...10 x In DC
Mechanical Durability20000 cycles
Mounting Modeclip-on
Net Weight0.128 kg
Provision For Padlockingpadlockable
Tightening Torque2.5-2.5 N.m top or bottom
Width18 mm
Wire Stripping Length14 mm for top or bottom connection
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to EN/IEC 60947-2
[Ui] Rated Insulation Voltage500 V DC conforming to EN/IEC 60947-2
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-40-85 °C
Heat Dissipation2.5-2.5 W at 220 V - 16 A
IP Degree Of ProtectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution Degree3 conforming to EN/IEC 60947-2
Product CertificationsCCC
IEC
UR
Relative Humidity95-95 % at 55-55 °C
StandardsEN/IEC 60947-2
GB 14048.2
UL 1077
Tropicalisation2 conforming to GB 14048.2
2 conforming to IEC 60068-2
OTHER
Poles Description1P
[Us] Rated Supply VoltageMulti 9