Guard Switch, Telemecanique Safety Switches XCS, XCSTR, Spindle 30 Mm, 2NC+1 NO -1/2
Telemecanique
SKU
SE_XCSTR753
Model
XCSTR753
SGD $100.65
Short description of XCSTR753
Safety switches
Country of Origin
France
range of product : Telemecanique Safety switches XCS
-  product or component type : Guard switch
-  component name : XCSTR
-  material : Plastic
-  head type : Turret head rotary axis
-  insulation : Double insulated
-  type of operator : Spindle 30 mm
-  electrical connection : Terminal
-  contacts type and composition : 1 NC + 1 NC + 1 NO
-  contact operation : Slow-break, break before make
-  clamping connection capacity : 1 x 0.34...2 x 0.75 mm² with or without cable end
-  cable entry : 2 entries tapped for 1/2" NPT
-  number of poles : 3
-  product or component type : Guard switch
-  component name : XCSTR
-  material : Plastic
-  head type : Turret head rotary axis
-  insulation : Double insulated
-  type of operator : Spindle 30 mm
-  electrical connection : Terminal
-  contacts type and composition : 1 NC + 1 NC + 1 NO
-  contact operation : Slow-break, break before make
-  clamping connection capacity : 1 x 0.34...2 x 0.75 mm² with or without cable end
-  cable entry : 2 entries tapped for 1/2" NPT
-  number of poles : 3
MAIN SPECIFICATIONS | |
---|---|
Contacts Type And Composition | 1 NC + 1 NC + 1 NO |
Continuous Power | can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508 |
Discrete Input Number | 1 NC + 1 NC + 1 NO |
Product Or Component Type | guard switch |
Range Of Product | Telemecanique Safety switches XCS |
Component Name | XCSTR |
Enclosure Material | polyamide PA66 fibre glass impregnated |
Head Type | turret head rotary axis |
Number Of Poles | 3 |
Range Name | Preventa XCS |
Short-circuit Protection | 6 A cartridge fuse type gG (gl) |
Type Of Operator | spindle 30 mm |
[Ithe] Conventional Enclosed Thermal Current | 6 A |
COMPLEMENTARY | |
Cable Entry | 2 entries tapped for 1/2" NPT |
Cable Outer Diameter | 7-10 mm |
Clamping Connection Capacity | 1 x 0.34...2 x 0.75 mm² with or without cable end |
Contact Code Designation | B300, AC-15 (Ue = 120 V, Ie = 6 A) conforming to EN/IEC 60947-5-1 B300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1 Q300, DC-13 (Ue = 125 V, Ie = 0.2 A) conforming to EN/IEC 60947-5-1 R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1 |
Contact Operation | slow-break, break before make |
Depth | 60 mm |
Electrical Connection | terminal |
Height | 117-117 mm |
Insulation | double insulated |
Lever Material | stainless steel |
Material | plastic |
Maximum Resistance Across Terminals | 30 mOhm conforming to EN/IEC 60947-5-4 |
Mechanical Durability | 1000000 cycles |
Minimum Actuation Speed | 0.1 m/s |
Minimum Torque For Tripping | 0.1 N.m |
Net Weight | 0.155 kg |
Positive Opening | with NC contact |
Positive Opening Minimum Torque | 0.45 N.m |
Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
Tripping Angle | 5 ° |
Width | 52 mm |
[Uimp] Rated Impulse Withstand Voltage | 4 kV conforming to EN/IEC 60947-5-1 |
[Ui] Rated Insulation Voltage | 300 V conforming to CSA C22.2 No 14 300 V conforming to UL 508 400 V (pollution degree 3) conforming to EN/IEC 60947-1 |
ENVIRONMENT | |
Safety Level | can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508 |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Electrical Shock Protection Class | class II conforming to EN/IEC 61140 |
IP Degree Of Protection | IP67 conforming to IEC 60529 |
Product Certifications | BG CSA UL |
Protective Treatment | TC TH |
Shock Resistance | 50 gn for 11 ms conforming to IEC 60068-2-27 |
Standards | CSA C22.2 No 14 EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/IEC 60947-5-4 EN/ISO 12100 UL 508 |
Vibration Resistance | 50 gn (f= 10-500 Hz) conforming to IEC 60068-2-6 |
OTHER | |
Poles Description | guard switch |
[Us] Rated Supply Voltage | Telemecanique Safety switches XCS |
Write Your Own Review