Safety Switch, Telemecanique Safety Switches XCS, Plastic XCSTE, 1NC + 1 NO, Slow Break, 1 Entry Tapped Pg 11 24 V.
Telemecanique
SKU
SE_XCSTE5511
Model
XCSTE5511
SGD $320.41
Short description of XCSTE5511
Safety switches
Country of Origin
France
range of product : Telemecanique Safety switches XCS
-  product or component type : Safety switch
-  component name : XCSTE
-  design : Rectangular
-  material : Plastic
-  head type : Key operated turret head
-  contacts type and composition : 1 NC + 1 NO
-  contact operation : Slow-break, break before make
-  solenoid contacts type and composition : 1 NC (slow-break)
-  cable entry : 1 entry tapped for Pg 11
-  electromagnet interlocking : Locking on energisation and unlocking on de
- energisation of solenoid
-  [Us] solenoid rated supply voltage : 24 V
-  20...10 %
-  cable outer diameter : 7…10 mm
-  electrical connection : Terminal, clamping capacity :  1 x 0.5...2 x 1.5 mm² with or without cable end
-  number of poles : 2
-  locking options description : With interlocking, locking by solenoid
-  product or component type : Safety switch
-  component name : XCSTE
-  design : Rectangular
-  material : Plastic
-  head type : Key operated turret head
-  contacts type and composition : 1 NC + 1 NO
-  contact operation : Slow-break, break before make
-  solenoid contacts type and composition : 1 NC (slow-break)
-  cable entry : 1 entry tapped for Pg 11
-  electromagnet interlocking : Locking on energisation and unlocking on de
- energisation of solenoid
-  [Us] solenoid rated supply voltage : 24 V
-  20...10 %
-  cable outer diameter : 7…10 mm
-  electrical connection : Terminal, clamping capacity :  1 x 0.5...2 x 1.5 mm² with or without cable end
-  number of poles : 2
-  locking options description : With interlocking, locking by solenoid
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 24 V - 20...10 % |
Contacts Type And Composition | 1 NC + 1 NO |
Continuous Power | can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 |
Discrete Input Number | 1 NC + 1 NO |
Product Or Component Type | safety switch |
Range Of Product | Telemecanique Safety switches XCS |
[Ie] Rated Operational Current | 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1 3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1 |
[Ue] Rated Operational Voltage | 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1 3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1 |
Body Material | PA (polyamide) |
Component Name | XCSTE |
Design | rectangular |
Electromagnet Interlocking | locking on energisation and unlocking on de-energisation of solenoid |
Head Type | key operated turret head |
Number Of Poles | 2 |
Range Name | Preventa XCS |
Short-circuit Protection | 10 A cartridge fuse type gG (gl) |
Solenoid Contacts Type And Composition | 1 NC (slow-break) |
[Ithe] Conventional Enclosed Thermal Current | 6 A |
COMPLEMENTARY | |
Actuator Forcible Withdrawal Rtc | 500 N |
Cable Entry | 1 entry tapped for Pg 11 |
Cable Outer Diameter | 7-10 mm |
Contact Operation | slow-break, break before make |
Depth | 33 mm |
Electrical Connection | terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end |
Head Material | PA (polyamide) |
Height | 94-94 mm |
Insulation | double insulated |
Load Factor | 1 |
Locking Options Description | with interlocking, locking by solenoid |
Material | plastic |
Maximum Actuation Speed | 0.5 m/s |
Maximum Operating Rate | 10 cyc/mn for maximum durability |
Mechanical Durability | 1000000 cycles |
Minimum Actuation Speed | 0.01 m/s |
Net Weight | 0.36 kg |
Positive Opening | with NC contact |
Positive Opening Minimum Force | 15 N |
Power Consumption In VA | 10 VA |
Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
Supply Frequency | 50/60 Hz |
Supply Voltage Type | AC/DC |
Width | 110 mm |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to EN/IEC 60947-5-1 |
[Ui] Rated Insulation Voltage | 300 V conforming to CSA C22.2 No 14 300 V conforming to UL 508 500 V conforming to EN/IEC 60947-1 |
ENVIRONMENT | |
Safety Level | can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 |
Ambient Air Temperature For Operation | -25-60 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Electrical Shock Protection Class | class II conforming to EN/IEC 61140 |
IP Degree Of Protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |
Product Certifications | CSA UL |
Protective Treatment | TC |
Shock Resistance | 10 gn for 11 ms conforming to IEC 60068-2-27 |
Standards | CSA C22.2 No 14 EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 UL 508 |
Vibration Resistance | 5 gn (f= 10-500 Hz) conforming to IEC 60068-2-6 |
OTHER | |
Poles Description | safety switch |
[Us] Rated Supply Voltage | 24 V - 20...10 % |