Module XPSAV - Emergency Stop - 24 V DC, Time Delay 0...300 S.

Schneider
SKU
SE_XPSAV11113P
Model
XPSAV11113P

Obsolete

Short description of XPSAV11113P

Safety Modules
Obsolete
*All information are subjected to changes without prior notice.
range of product : Preventa Safety automation
-  product or component type : Preventa safety module
-  safety module name : XPSAV
-  safety module application : For emergency stop and switch monitoring
-  function of module : Monitoring of a movable guard associated with 2 switches automatic startEmergency stop monitoring 1-channel wiringEmergency stop button with 1 NC contact, automatic start or unmonitored startEmergency stop monitoring 2-channel wiringEmergency stop button with 2 NC contacts, monitored start
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061
-  safety reliability data : DC > 99 % conforming to EN/ISO 13849-1MTTFd = 75.8 years conforming to EN/ISO 13849-1PFHd = 7.95E
- 9 1/h conforming to EN/IEC 62061
-  type of start : Configurable
-  connections
-  terminals : Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
-  output type : Relay instantaneous opening, 3 NO circuit(s), volt
- freeRelay time delay opening, 3 NO circuit(s), volt
- free
-  number of additional circuits : 3 solid state outputs
-  [Us] rated supply voltage : 24 V DC
-  20...20 %
MAIN SPECIFICATIONS
Analogue Input Number24 V DC - 20...20 %
Breaking Capacity1.25 A at 24 V (DC-13) time constant: 50 ms for relay output
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
20 mA at 24 V
Continuous Powercan reach PL e/category 4 conforming to EN/ISO 13849-1
can reach SILCL 3 conforming to EN/IEC 62061
Product Or Component TypePreventa safety module
Range Of ProductPreventa Safety automation
Thread Type0...300 s
[Uc] Control Circuit Voltage24 V DC
Function Of Moduleemergency stop button with 1 NC contact, automatic start or unmonitored start
emergency stop button with 2 NC contacts, monitored start
emergency stop monitoring 1-channel wiring
emergency stop monitoring 2-channel wiring
monitoring of a movable guard associated with 2 switches automatic start
Mounting Support35 mm symmetrical DIN rail
Number Of Additional Circuits3 solid state outputs
Range NamePreventa XPS
Safety Module Applicationfor emergency stop and switch monitoring
Safety Module NameXPSAV
Type Of Startconfigurable
COMPLEMENTARY
Interlocked Device1.25 A at 24 V (DC-13) time constant: 50 ms for relay output
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
20 mA at 24 V
Product Namerelay instantaneous opening, 3 NO circuit(s), volt-free
relay time delay opening, 3 NO circuit(s), volt-free
Time Delay Range0...300 s
Associated Fuse Rating4 A gG or gL for instantaneous and time delay outputs conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Connections - Terminalscaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel
captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel
captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel
captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel
captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Input Protection Typeinternal, electronic
Local Signalling11 LEDs
Maximum Line Resistance100 Ohm <2000 m
Maximum Power Consumption In W5 W DC
Maximum Response Time On Input Open30 ms
Minimum Output Current10 mA for relay output
Minimum Output Voltage17 V for relay output
Net Weight0.32 kg
Output Thermal Current2 A for 1 output and 4 A for the other 2 outputs for instantaneous and time delay outputs
3.3 A for all 3 outputs for instantaneous and time delay outputs
6 A for 1 output and 2 A for the other 2 outputs for instantaneous and time delay outputs
Output Typerelay instantaneous opening, 3 NO circuit(s), volt-free
relay time delay opening, 3 NO circuit(s), volt-free
Safety Reliability DataDC > 99 % conforming to EN/ISO 13849-1
MTTFd = 75.8 years conforming to EN/ISO 13849-1
PFHd = 7.95E-9 1/h conforming to EN/IEC 62061
Synchronisation Time Between Inputs1.5 s for guard
unlimited for emergency stop
[Ith] Conventional Free Air Thermal Current20 A
[Uimp] Rated Impulse Withstand Voltage4 kV overvoltage category III conforming to DIN VDE 0110 part 1
4 kV overvoltage category III conforming to IEC 60947-5-1
[Ui] Rated Insulation Voltage300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
300 V (pollution degree 2) conforming to IEC 60947-5-1
ENVIRONMENT
Safety Levelcan reach PL e/category 4 conforming to EN/ISO 13849-1
can reach SILCL 3 conforming to EN/IEC 62061
Ambient Air Temperature For Operation-10-55 °C
Ambient Air Temperature For Storage-25-85 °C
IP Degree Of ProtectionIP20 (terminals) conforming to EN/IEC 60529
IP40 (enclosure) conforming to EN/IEC 60529
Product CertificationsCSA
TÜV
UL
StandardsEN 1088/ISO 14119
EN/IEC 60204-1
EN/IEC 60947-5-1
EN/ISO 13850
OTHER
Poles DescriptionPreventa safety module
[Us] Rated Supply Voltage24 V DC - 20...20 %