SGD $264.52

Short description of GV3P50

GV3P MOTOR CB THERM/MAG 37-50A EVERLINK
Country of Origin
France
-
+

UOM: Piece

In stock
In Stock 5
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
TeSys GV3-Circuit breaker
- thermal
- magnetic
-  37…50A
-  EverLink BTR connectors.
Label :  TeSys GV3
-  range of product :  TeSys GV3
-  range :  TeSys
-  trip unit technology :  thermal
- magnetic
-  product name :  TeSys GV3
-  device short name :  GV3P
-  product or component type :  circuit breaker
-  device application :  motor
-  Range Presentation :  Can be easily integrated with all configurations, thanks to their 55 mm standard width and mounting on DIN rail.
GV3 P Thermal
- Magnetic Breaker : 

-  7 ratings from 9 to 65 A used for magnetic and thermal motor protection from 5.5 to 30 kW. GV3 L Magnetic Breaker : 

-  5 ratings from 25 to 65 A used for magnetic motor protection from 11 to 30 kW. Common characteristics : 

-  50 kA Icu breaking capacity from 40 to 65A and 100 kA Icu from 9 to 32 A, complying with international standards and certifications.
-  Product compacity :  55 mm standard width provides an easier installation in the panel and space saving, mounting on DIN rail
-  Sturdiness and safety with 3-position rotary handle, front face padlocking.
-  Common additives parts for TeSys GV2 and GV3 ranges.
-  Range Benefits :  A stronger, safer, and long
- term connection
Designed with the new and ingenious, EverLink* patented, power terminal system, The TeSys GV3 circuit-breaker provides a more reliable connection quality :  the tightening pressure applied to the cables remains stable, strong and long
- lasting even under tough conditions. Common additive parts to GV2 and GV3 ranges provide simplicity and significant installation time saving.
-  Range Application Presentation : 

-  Industry, infrastructures, buildings : 
Used for motor control and protection, complying with IEC 947-2 and IEC 947-4-1 standards.

*Schneider patent
MAIN SPECIFICATIONS
Breaking Capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Contacts Type And Composition50 A
Control Typerotary knob
Product Or Component Typecircuit breaker
Range Of ProductTeSys GV3
[Ie] Rated Operational Currentrotary knob
[Ue] Rated Operational Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Device Short NameGV3P
EAN133389119405409
Network TypeAC
Power Dissipation Per Pole8 W
RangeTeSys
TeSys Deca
Range NameTeSys GV3
Suitability For Isolationyes conforming to IEC 60947-1
Trip Unit Technologythermal-magnetic
Utilisation CategoryAC-3 conforming to IEC 60947-4-1
category A conforming to IEC 60947-2
[Ics] Rated Service Short-circuit Breaking Capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
COMPLEMENTARY
Communication Network Type690 V AC 50/60 Hz conforming to IEC 60947-2
Interlocked Device100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Product NameTeSys Deca
TeSys GV3
[In] Rated Current50 A
Colourdark grey
Compatibility CodeGV3P
Depth136 mm
Device Applicationmotor
Direct Connectorwithout
Electrical Durability50000 cycles for AC-3 at 440 V In
Fixing Mode35 mm symmetrical DIN rail: clipped
panel: screwed (with 3 x M4 screws)
Height132 mm
Magnetic Tripping Current700-700 A
Maximum Operating Rate25 cyc/h
Mechanical Durability50000 cycles
Motor Power KW22-22 kW at 400/415 V AC 50/60 Hz
30-30 kW at 500 V AC 50/60 Hz
45-45 kW at 690 V AC 50/60 Hz
Net Weight0.96 kg
Network Frequency50/60 Hz conforming to IEC 60947-4-1
Operating Positionany position
Phase Failure Sensitivityyes conforming to IEC 60947-4-1
Rated Dutycontinuous conforming to IEC 60947-4-1
Tightening Torque5 N.m on EverLink BTR screw connectors for cable 25-25 mm²
8 N.m on EverLink BTR screw connectors for cable 35-35 mm²
Trip Unit Rating37-50 A
Width55 mm
[Ith] Conventional Free Air Thermal Current50 A conforming to IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947-2
[Ui] Rated Insulation Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
ENVIRONMENT
Ambient Air Temperature For Operation-20-60 °C
Ambient Air Temperature For Storage-40-80 °C
Fire Resistance960 °C conforming to IEC 60695-2-1
IK Degree Of ProtectionIK09
IP Degree Of ProtectionIP20 conforming to IEC 60529
Operating Altitude3000 m
Product CertificationsABS
ATEX
BV
CCC
CSA
DNV-GL
EAC
IECEE CB Scheme
LROS (Lloyds register of shipping)
UKCA
UL
Protective TreatmentTH
StandardsCSA C22.2 No 60947-4-1
EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
OTHER
Poles Description3P
[Us] Rated Supply VoltageTeSys GV3