Motor Circuit Breaker, TeSys GV2, 3P, 1.6-2.5 A, Thermal Magnetic, Screw Clamp Terminals

Schneider
SKU
SE_GV2P07
Model
GV2P07
Special Price SGD $74.17 Regular Price SGD $92.22

Short description of GV2P07

MOTOR CIRCUIT BREAKER CTR Promo
Country of Origin
Thailand
-
+

UOM: Piece

In stock
In Stock 8
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
TeSys GV2
-  Motor circuit breaker
-  thermal
- magnetic
-  1.6…2.5 A.
Label :  TeSys GV2
-  range of product :  TeSys GV2
-  range :  TeSys
-  trip unit technology :  thermal
- magnetic
-  product name :  TeSys GV2
-  device short name :  GV2P
-  product or component type :  circuit breaker
-  device application :  motor
-  Range Presentation : 
-  Manual and local control, when the motor circuit-breaker is used on its own, and automatic and remote control when combined with a contactor
-  Motor protection provided by thermal
- magnetic devices built into the circuit-breaker
-  No live parts are accessible to direct finger contact
-  The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost
-  The addition of a shunt trip enables remote control of tripping
-  The control for the open or enclosed motor circuit-breaker can be locked in the “N/C" position using 3 padlocks
-  Connectors :  spring terminal, screw clamp
-  Range Benefits :  Complete protection concentrated in a single productCompact and simple to select, TeSys GV2 motor circuit-breakers are only 45 mm wide and are categorised
according to their level of performance and functions :  type of control, breaking capacity, motor protection and accessories.
-  Range Application Presentation : 
-  Industry, infrastructure, building, etc : 
-  Motor control and protection, in accordance with standards IEC 947-2 and IEC 947-4-1
-  Easily inserted in any configuration by screw or clip-fixing onto mounting rails
MAIN SPECIFICATIONS
Breaking Capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Contacts Type And Composition2.5 A
Control Typerotary knob
Product Or Component Typecircuit breaker
Range Of ProductTeSys GV2
[Ie] Rated Operational Currentrotary knob
[Ue] Rated Operational Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Device Short NameGV2P
EAN133389110213461
Network TypeAC
Power Dissipation Per Pole2.5 W
RangeTeSys
TeSys Deca
Range NameTeSys GV2
Suitability For Isolationyes conforming to IEC 60947-1
Trip Unit Technologythermal-magnetic
Utilisation CategoryAC-3 conforming to IEC 60947-4-1
category A conforming to IEC 60947-2
[Ics] Rated Service Short-circuit Breaking Capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
COMPLEMENTARY
Communication Network Type690 V AC 50/60 Hz conforming to IEC 60947-2
Interlocked Device100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Product NameTeSys Deca
TeSys GV2
[In] Rated Current2.5 A
Colourdark grey
Compatibility CodeGV2P
Depth97 mm
Device Applicationmotor
Direct Connectorwithout
Electrical Durability100000 cycles for AC-3 at 440 V
Fixing Mode35 mm symmetrical DIN rail: clipped
panel: screwed (with 2 x M4 screws)
Height89 mm
Magnetic Tripping Current33.5-33.5 A
Maximum Operating Rate25 cyc/h
Mechanical Durability100000 cycles
Motor Power KW0.75-0.75 kW at 400/415 V AC 50/60 Hz
1.1-1.1 kW at 500 V AC 50/60 Hz
1.5-1.5 kW at 690 V AC 50/60 Hz
Network Frequency50/60 Hz conforming to IEC 60947-4-1
Operating Positionany position
Phase Failure Sensitivityyes conforming to IEC 60947-4-1
Rated Dutycontinuous conforming to IEC 60947-4-1
Tightening Torque1.7 N.m on screw clamp terminals
Trip Unit Rating1.6-2.5 A
Width45 mm
[Ith] Conventional Free Air Thermal Current2.5 A conforming to IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947-2
[Ui] Rated Insulation Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
ENVIRONMENT
Ambient Air Temperature For Operation-20-60 °C
Ambient Air Temperature For Storage-40-80 °C
Fire Resistance960 °C conforming to IEC 60695-2-1
IK Degree Of ProtectionIK04
IP Degree Of ProtectionIP20 conforming to IEC 60529
Operating Altitude2000 m
Product CertificationsATEX
BV
CCC
CSA
DNV-GL
EAC
IECEE CB Scheme
LROS (Lloyds register of shipping)
RINA
UKCA
UL
Protective TreatmentTH
StandardsCSA C22.2 No 60947-4-1
EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
OTHER
Poles Description3P
[Us] Rated Supply VoltageTeSys GV2