Contactor, TeSys K, 4P, 4 NO, AC-1, lt or eq to 440V 10A, 220 to 230VAC coil
Schneider
SKU
SE_LC1K09004M7
Model
LC1K09004M7
SGD $43.26
Short description of LC1K09004M7
TeSys K contactor, 4 poles (4NO), for non-inductive load control applications up to 20A/690V AC-1. It provides a 220V 50/60Hz AC coil, without built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Country of Origin
Indonesia
TeSys K is a compact contactor range with a wide variety of coil voltage and terminal connection options
The offer features specific versions for railway (TeSys S207) and electrodomestic (TeSys S335) applications
One of the smallest contactor offerings in the market
The range delivers strong performance for its compact size and promises seamless integration in all applications.
Widely used for industry, infrastructure and building applications
MAIN | |
---|---|
Range | TeSys |
Product Or Component Type | Contactor |
Device Short Name | LC1K |
Device Application | Control |
Contactor Application | Resistive load |
COMPLEMENTARY | |
Utilisation Category | AC-1 |
Poles Description | 4P |
Power Pole Contact Composition | 4 NO |
[Ue] Rated Operational Voltage | Power circuit <= 690 V AC <= 400 Hz Signalling circuit <= 690 V AC <= 400 Hz |
[Ie] Rated Operational Current | 20 A 140 °F (60 °C)) <= 690 V AC AC-1 power circuit |
Control Circuit Type | AC 50/60 Hz |
[Uc] Control Circuit Voltage | 220...230 V AC 50/60 Hz |
[Uimp] Rated Impulse Withstand Voltage | 8 kV |
Overvoltage Category | III |
[Ith] Conventional Free Air Thermal Current | 20 A 140 °F (60 °C) power circuit 10 A 122 °F (50 °C) signalling circuit |
Irms Rated Making Capacity | 110 A AC power circuit IEC 60947 |
Rated Breaking Capacity | 110 A 220...230 V IEC 60947 110 A 380...400 V IEC 60947 110 A 415 V IEC 60947 110 A 440 V IEC 60947 80 A 500 V IEC 60947 70 A 660...690 V IEC 60947 |
[Icw] Rated Short-time Withstand Current | 90 A 122 °F (50 °C) - 1 s power circuit 85 A 122 °F (50 °C) - 5 s power circuit 80 A 122 °F (50 °C) - 10 s power circuit 60 A 122 °F (50 °C) - 30 s power circuit 45 A 122 °F (50 °C) - 1 min power circuit 40 A 122 °F (50 °C) - 3 min power circuit 20 A 122 °F (50 °C) - >= 15 min power circuit |
Associated Fuse Rating | 25 A gG <= 440 V power circuit 25 A aM power circuit |
Average Impedance | 3 mOhm - Ith 20 A 50 Hz power circuit |
[Ui] Rated Insulation Voltage | Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA C22.2 No 14 |
Inrush Power In VA | 30 VA 68 °F (20 °C)) |
Hold-in Power Consumption In VA | 4.5 VA 68 °F (20 °C)) |
Heat Dissipation | 1.3 W |
Control Circuit Voltage Limits | Operational 0.8...1.15 Uc 122 °F (50 °C)) Drop-out >= 0.20 Uc 122 °F (50 °C)) |
Connections - Terminals | screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end |
Maximum Operating Rate | 3600 cyc/h |
Signalling Circuit Frequency | <= 400 Hz |
Mounting Support | Rail Plate |
Tightening Torque | 7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2 7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm 7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2 |
Operating Time | 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical Durability | 10 Mcycles |
Electrical Durability | 0.16 Mcycles 20 A AC-1 <= 690 V |
Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 |
Height | 2.28 in (58 mm) |
Width | 1.77 in (45 mm) |
Depth | 2.24 in (57 mm) |
Net Weight | 0.40 lb(US) (0.18 kg) |
ENVIRONMENT | |
Standards | EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 |
Product Certifications | CB Scheme CCC UL CSA EAC CE UKCA |
IP Degree Of Protection | IP2X VDE 0106 |
Protective Treatment | TC IEC 60068 TC DIN 50016 |
Ambient Air Temperature For Storage | -58…176 °F (-50…80 °C) |
Operating Altitude | 6561.68 ft (2000 m) without derating |
Flame Retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
ORDERING AND SHIPPING DETAILS | |
Category | 22326-CTR,K-LINE,AC,OPEN,NONREV |
Discount Schedule | I12 |
GTIN | 3389110488449 |
Returnability | No |
Country Of Origin | FR |