F204 B-125/0.5-L Residual Current Circuit Breaker
ABB
SKU
AB_2CSF204523R4950
Model
F204-B-125/0.5-L
SGD $4,183.78
Short description of F204 B 125/0.5 L
F204 B-125/0.5-L Residual Current Circuit Breaker
Country of Origin
Germany (DE)
The RCCBs F200 series assures protection to people and installations against fault current to earth. A large offer for standard instantaneous and selective AC and A types is completed with some configurations for special applications. This product is particularly suitable for the protection against smooth d.c. earth fault currents. This product is suitable for installations where neutral on the left is .
MAIN SPECIFICATION | |
---|---|
ABB Global ID | ABB2CSF204523R4950 |
Business Area (Master Data) Name | Electrification |
Catalog Description | F204 B-125/0.5-L Residual Current Circuit Breaker |
Division (Master Data) Name | Smart Buildings |
EAN | 8012542730439 |
Rated Insulation Voltage (Ui) | 500 volt |
SKU ID | 2CSF204523R4950 |
TECHNICAL | |
Accessories Available | Yes |
Connecting Capacity | Busbar 10 mm² Rigid 35 ... 35 mm² Flexible 35 ... 35 mm² |
Electrical Endurance | 10000 cycle |
Housing Type | Insulation group I - II, RAL 7035 |
Maximum Surge Current | 3 kA |
Operating Characteristic | Instantaneous |
Options Provided | None |
Pollution Degree | 2 |
Position Of Neutral Terminals | Left |
Power Loss | at Rated Operating Conditions per Pole 7.5 W |
Power Supply Connection | Arbitrary |
Product Name | Residual Current Circuit Breaker |
Rated Cross-Section | 4 - Multi-Wired 0...25 mm² 1 - Solid-Core 35...35 mm² |
Rated Frequency (f) | 50 Hz |
Standards | IEC/EN 61008 |
TECHNICAL UL/CSA | |
Short-Circuit Current Rating (SCCR) | 0.5 A |
DIMENSIONS | |
Built-In Depth (t2) | 69 mm |
ORDERING | |
Minimum Order Quantity | 1 piece |
Selling Unit Of Measure | piece |
ENVIRONMENTAL | |
Ambient Temperature | -25...40 °C |
RoHS Status | Following EU Directive 2011/65/EU |
CLASSIFICATIONS | |
CN8 | 85363030 |
E-Number (Finland) | 3210605 |
EPLAN Catalog Tree | Electrical engineering / Protection devices / Ground fault current circuit breaker |
ETIM 6 | EC000003 - Residual current circuit breaker (RCCB) |
ETIM 7 | EC000003 - Residual current circuit breaker (RCCB) |
ETIM 8 | EC000003 - Residual current circuit breaker (RCCB) |
Object Classification Code | F |
WEEE B2C / B2B | Business To Consumer |
POPULAR DOWNLOADS | |
EPLAN Macro | 9AKK106930A1242 |
OTHER | |
Actuator Type | Toggle - Insulation group I - II, RAL 5015 |
Ambient Air Temperature | Operation -25...40 °C |
Degree Of Protection | IP2X |
Input Voltage Type | AC |
Leakage Current Type | B |
Mounting Type | DIN rail |
Number Of Poles | 4 |
Product Net Width | 0.072 |
Rated Conditional Short-Circuit Current (Inc) | 10 kA |
Rated Current (In) | 125 A |
Rated Impulse Withstand Voltage (Uimp) | 4 kilovolt |
Rated Operational Voltage | 230/400 V |
Rated Residual Current | 500 mA |
Rated Service Short-Circuit Breaking Capacity (Ics) | 1 kA |
Rated Voltage (Ur) | 230/400 V |
Type Of Residual Current | B type |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
Width In Number Of Modular Spacings | 4 |
Write Your Own Review