A26-30-10 380-400V 50Hz / 400-415V 60Hz Contactor

ABB
SKU
AB_1SBL241001R8510
Model
A26-30-10-380-400V-50Hz-/-400-415V-60Hz
SGD $72.42

Short description of A26 30 10 380 400V 50Hz / 400 415V 60Hz

A26-30-10 380-400V 50Hz / 400-415V 60Hz Contactor
Country of Origin
Bulgaria (BG)
-
+

UOM: Piece

In stock
In Stock 0

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
A26 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.
MAIN SPECIFICATION
ABB Global IDABB1SBL241001R8510
Business Area (Master Data) NameElectrification
Catalog DescriptionA26-30-10 380-400V 50Hz / 400-415V 60Hz Contactor
Division (Master Data) NameSmart Power
EAN3471522062857
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 volt
acc. to UL/CSA 600 volt
SKU ID1SBL241001R8510
TECHNICAL
Coil ConsumptionAverage Holding Value 50 / 60 Hz 12 V·A
Average Pull-in Value 50 Hz 125 V·A
Average Pull-in Value 60 Hz 120 V·A
Connecting Capacity Auxiliary CircuitFlexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Connecting Capacity Main CircuitFlexible with Cable End 0.75 ... 4 mm²
Rigid Cable 1.5 ... 6 mm²
Connecting Terminals (delivered In Open Position) Main PolesM 4 (+,-) pozidriv 2 screws with cable clamp
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 45 A
acc. to IEC 60947-5-1, q = 40 °C 16 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
(AC-2 / AC-4) 300 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Mechanical Durability10 million
Operate TimeBetween Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing 8 ... 21 ms
Rated Breaking Capacity AC-3 Acc. To IEC 60947-4-18 x Ie AC-3
Rated Frequency (f)Supply Circuit 50 / 60 Hz
Rated Making Capacity AC-3 Acc. To IEC 60947-4-110 x Ie AC-3
Rated Operational Current AC-15 (Ie)(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
Rated Operational Current DC-13 (Ie)(24 V) 6 / 144 A
(48 V) 2.8 / 134 A
(72 V) 2 / 144 A
(125 V) 1.1 / 138 A
(250 V) 0.55 / 138 A
Short-Circuit Protective DevicesAuxiliary Circuit - gG Type Fuses 10 A
gG Type Fuses 50 A
Terminal TypeScrew Terminals
ORDERING
Minimum Order Quantity1 piece
ENVIRONMENTAL
Climatic Withstandacc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible3000 m
Resistance To Shock Acc. To IEC 60068-2-27Closed, Shock Direction: B1 10 K40
Open, Shock Direction: B1 5 K40
Shock Direction: A 20 K40
Shock Direction: B2 15 K40
Shock Direction: C1 20 K40
Shock Direction: C2 20 K40
RoHS StatusFollowing EU Directive 2011/65/EU
CLASSIFICATIONS
EClassV11.0 : 27371003
ETIM 4EC000066 - Magnet contactor, AC-switching
ETIM 5EC000066 - Magnet contactor, AC-switching
ETIM 6EC000066 - Power contactor, AC switching
ETIM 7EC000066 - Power contactor, AC switching
Object Classification CodeQ
UNSPSC39121529
OTHER
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C
Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
Close to Contactor for Storage -60 ... +80 °C
Degree Of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Number Of Auxiliary Contacts NO1
Number Of Main Contacts NO3
Product Net Width54
Rated Control Circuit Voltage (Uc)50 Hz 380 ... 400 V
60 Hz 400 ... 415 V
Rated Impulse Withstand Voltage (Uimp)8 kilovolt
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 45 No unit
(690 V) 55 °C 40 No unit
(690 V) 70 °C 32 No unit
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 26 A
(440 V) 55 °C 26 A
(500 V) 55 °C 22 A
(690 V) 55 °C 17 A
(380 / 400 V) 55 °C 26 A
(220 / 230 / 240 V) 55 °C 26
Rated Operational Power AC-3 (Pe)(415 V) 11 kW
(440 V) 15 kW
(500 V) 15 kW
(690 V) 15 kW
(380 / 400 V) 11 kW
(220 / 230 / 240 V) 6.5 kW
Rated Operational Power AC-6b (Pe)(230 / 240 V) 40 °C, 50 / 60 Hz 11.5 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 11.5 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 9 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 19 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 15 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 19 kvar
(440 V) 40 °C, 50 / 60 Hz 20 kvar
(440 V) 55 °C, 50 / 60 Hz 20 kvar
(440 V) 70 °C, 50 / 60 Hz 16.5 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 23 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 23 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 19 kvar
(690 V) 40 °C, 50 / 60 Hz 32 kvar
(690 V) 55 °C, 50 / 60 Hz 32 kvar
(690 V) 70 °C, 50 / 60 Hz 26 kvar
Rated Operational VoltageMain Circuit 690 V