Singapore GST will increase from 8% to 9%

(Effective from Jan 1, 2024)

Electgo: Your trusted Source for Electrical Components in Singapore

An Authorized Supplier Offering a Comprehensive Range of Electrical Component Categories

Loading...

Active Harmonic Filter - 60 A 380..480 V AC - IP31 Enclosure

Schneider
SKU
SE_PCSP060D5IP31
Model
PCSP060D5IP31
SGD $61,262.75

Short description of PCSP060D5IP31

AccuSine PCS+ 60A 380-480 VAC IP31
Country of Origin
India
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 18 To 20 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
Active harmonic filter
-  60 A 380..480 V AC
-  IP31 enclosure.
Label :  AccuSine PCS+
-  range of product :  AccuSine
-  range :  AccuSine
-  product name :  AccuSine PCS+
-  product or component type :  active harmonic filter
-  Range Presentation : 
-  A complete solution for harmonic filtering that meets every harmonic standard around the world.
-  Can be operated as a displacement power factor correction and load balancing device independent of or in conjunction with harmonic mitigation.
Technical Data
Standard RMS output current ratings
-  60 A, 120 A, 200 A, 300 A
-  380 V AC to 480 V AC
-  47 A, 94 A, 157 A, 235 A
-  480-600 V AC
-  40 A, 80 A, 133 A , 200 A
-  600-690 V AC
Nominal voltage
-  380-480 V AC; +10%/-15%
-  480-600 V AC; +10%/-15%
-  600-690 V AC; +10%/-15%
Up to 15kV with custom transformers
Nominal frequency
-  50/60 Hz, ±3 Hz auto sensing
Number of phases
-  3-phase, with or without neutral
Spectrum cancellation
-  2nd to 51st, discrete; fully selectable per harmonic order (amplitude and on/off)
Harmonic Attenuation
-  Closed Loop :  3 % THD(i); max 20 : 1 THD(i) reduction with load harmonic current above 50 % of AccuSine PCS+ rating
-  Open Loop :  5 % TDD
-  Requires 3 % or higher inductive impedance per nonlinear load
Power factor correction
-  Optimized unity PF, Leading (capacitive) or lagging (inductive) power factor (Cos φ) to target
Mains current balancing
-  Negative sequence current injected to balance fundamental current on the mains due to load imbalance (inherently corrects displacement PF (Cos φ))
Control response time
-  25 μs
Harmonic correction time
-  2 cycles
Reactive correction time
-  1/4 cycle
Operating Temperature
-  60 A, 120 A & 200 A :  IP00, IP20, UL Type Open, & UL Type 1 configurations
- 0 °C to 45 °C
-  All others 0 °C to 40 °C
-  Derate 2 % per degree °C to 50 °C
Relative humidity
-  to 95 %, noncondensing
Operating Altitude
-  1000 m (derate 1 %/100 m above), max 4800 m
Standards compliance/ certification
-  cULus (UL508 , CSA 22.2 No. 14)
-  CE Certified, ABS, Lloyds, other local standards
Display
-  144 mm QVGA TFT 64k
- color touchscreen
-  Range Benefits :  Flexible and scalable : 
-  All types of harmonic producing loads
-  Single load, bus or global site filtering
-  Compatible with future load changes
-  Easy sizing and independent of system impedance
-  Simple selection online tool
-  Simple installation and ease of expansion
-  Flexible parallel operation modes for multi-unit installations
-  Current transformers can be installed on the incoming mains (source sense) or on the feeders to the loads (load sense) for maximum installation flexibility
-  Peace of mind : 
-  Achieves compliance with any harmonic standard anywhere around the world when sized correctly
-  Compatible with generator sources
-  off loads generators of reactive and harmonic current demands to extend life and ensure proper operation of generators
-  Compatible with UPS sources :  relieves UPS of reactive and harmonic current demands to ensure proper operation of UPS
-  Ensures energy efficiency by optimising transformer and cable capacities; reduces utility power factor penalties; and saves the cost of generation and transmission of reactive and harmonic current (non active currents)
-  Maximises up time when used for harmonic and/or power factor correction.
-  Range Application Presentation : 
-  Anywhere nonlinear loads are present :  water/wastewater facilities, HVAC systems, oil & gas platforms, petrochemical plants, port cranes, mining, pharmaceuticals, pulp & paper, automotive plants, all
- electric ships, wind mill and solar farms, steel mills, plastic extrusion plants, and more.
-  Stop voltage sags and flicker due to load current fluctuations (VAR compensation) :  Ball mills, shredders, arc welders, arc furnaces, hard to start AC motors, and more.
MAIN SPECIFICATIONS
Breaking Capacity200 kA
Control Typedoor-interlocked with rotary handle
Product Or Component Typeactive harmonic filter
Range Of ProductAccuSine
[Ie] Rated Operational Currentdoor-interlocked with rotary handle
EAN133606480851032
Function Availablerear plenum with forced ventilation for high heat flow
RangeAccuSine
Range NameAccuSine PCS+
Reactive Power Rating50 kvar 480 V AC 50/60 Hz
COMPLEMENTARY
Interlocked Device200 kA
Product NameAccuSine PCS+
Accessibility For Operationfront
Colourlight grey (RAL 7035)
Depth500 mm
Enclosure Mountingfloor-standing
Height2100 mm
Location Of Connectiontop or bottom
Maximum Permissible Voltage1.1 x Un
Mounting Locationindoor
Net Weight234 kg
Network Frequency50/60 Hz +/- 3 Hz auto sensing
Network Rated Voltage380-480 V AC
Neutral Protection Settingnot provided
Nominal Output Current60 A
Operating Modeharmonic cancellation
mains current balancing
power factor correction
Protection Typecircuit breaker protection
Width800 mm
Wiring Mode3 or 4 wires
ENVIRONMENT
Ambient Air Temperature For Operation0-40 °C
0-50 °C maximum with current derating of 2 % per °C
Ambient Air Temperature For Storage-20-60 °C
Electromagnetic Compatibilityconducted EMC, class A conforming to EN 61000-6-4
Environmental Characteristicoperating: 3C2 conforming to IEC 60721-3-3
operating: 3S2 conforming to IEC 60721-3-3
storage: 3C3 conforming to IEC 60721-3-3
storage: 3S3 conforming to IEC 60721-3-3
Impregnation Materialconformal coated
IP Degree Of ProtectionIP31
Operating Altitude<= 1000 m 1 % per 100 m
Product CertificationsABS
CE
cULus
RCM
Relative Humidity0-95 %
StandardsCSA C22.2 No 14
CSA C22.2 No 60947-1-07
EN 60439-1
EN 61000-6-4
UL 508
UL 60947-1
OTHER
Poles Description3P
[Us] Rated Supply VoltageAccuSine
Write Your Own Review
You're reviewing:Active Harmonic Filter - 60 A 380..480 V AC - IP31 Enclosure
Your Rating