Loading...

Circuit breaker, ComPacT NSX250H, 70kA/415VAC, 3 poles, MicroLogic 2.2M trip unit 220A

Schneider
SKU
SE_C25H32M220
Model
C25H32M220
SGD $1,190.47 All prices inclusive of GST

Short description of C25H32M220

This ComPacT NSX250H is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for motor protection applications. The breaking capacity (Icu) is 70kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds an electronic MicroLogic 2.2 M trip unit, with 220A rating. MicroLogic 2.2 M trip unit provides adjustable long time and short time protections, and fixed instantaneous protection. This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. ComPacT NSX250H is part of Schneider Electric EcoStruxure Power architecture.
Country of Origin
China
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 4 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
Schneider Electric green signature style for the entire ComPacT range
Estimated 40% reduction of wiring time for panel builders
Experience easier installation thanks to a new ergonomic front-plate design
Gain the confidence that all auxiliaries are on the right spot, and check that you have the right coil rating
Ergonomic new toggle for easier breaker manual operation
MAIN
RangeComPacT new generation
Product NameComPacT NSX new generation
Device Short NameNSX250H
Product Or Component TypeCircuit breaker
Device ApplicationMotor protection
Poles Description3P
Protected Poles Description3D
[In] Rated Current220 A at 65 °C
[Ue] Rated Operational Voltage690 V AC 50/60 Hz
Network TypeAC
Network Frequency50/60 Hz
Suitability For IsolationYes conforming to EN/IEC 60947-2
Utilisation CategoryCategory A
[Icu] Rated Ultimate Short-circuit Breaking Capacity100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 600 V AC 50/60 Hz conforming to UL 508
Performance LevelH 70 kA 415 V AC
Trip Unit NameMicroLogic 2.2 M
Trip Unit TechnologyElectronic
Trip Unit Protection FunctionsLSoI
Control TypeToggle
Circuit Breaker Mounting ModeFixed
COMPLEMENTARY
[Ui] Rated Insulation Voltage800 V AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage8 kV
[Ics] Rated Service Short-circuit Breaking Capacity100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical Durability20000 cycles
Electrical Durability20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power Dissipation Per Pole13.55 W
Mounting SupportBackplate
Mounting PositionHorizontal and vertical
Flat on the back
Upside ConnectionFront
Downside ConnectionFront
Connection Pitch35 mm
Protection TypeL : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip Unit Rating220 A at 65 °C
Motor Tripping Class20
5
10
Complementary Motor ProtectionPhase unbalance
Long-time Pick-up Adjustment Type Ir (thermal Protection)Adjustable 9 settings
[Ir] Long-time Protection Pick-up Adjustment Range100...220 A
Long-time Protection Delay Adjustment Type TrFixed
[tr] Long-time Protection Delay Adjustment Range120 s at 1.5 x Ir for trip class 5
6.5 s at 6 x Ir for trip class 5
5 s at 7.2 x Ir for trip class 5
240 s at 1.5 x Ir for trip class 10
13.5 s at 6 x Ir for trip class 10
10 s at 7.2 x Ir for trip class 10
480 s at 1.5 x Ir for trip class 20
26 s at 6 x Ir for trip class 20
20 s at 7.2 x Ir for trip class 20
Thermal Memory20 minutes before and after tripping
Short-time Protection Pick-up Adjustment Type IsdAdjustable 9 settings
[Isd] Short-time Protection Pick-up Adjustment Range5...13 x Ir
Short-time Protection Delay Adjustment Type TsdFixed
Instantaneous Protection Pick-up Adjustment Type IiFixed
[Ii] Instantaneous Protection Pick-up Adjustment Range3300 A
Earth-leakage ProtectionWithout
Zone Selective Interlocking ZSIWithout
Number Of Slots For Electrical Auxiliaries5 slot(s)
Local SignallingFlashing LED (green) for ready to operate
LED 95 % Ith (red) for temperature over set point
Width (W)105 mm
Height (H)161 mm
Depth (D)86 mm
Net Weight2.4 kg
ENVIRONMENT
StandardsEN/IEC 60947
Product CertificationsCCC
EAC
Marine
Overvoltage CategoryClass II
Electrical Shock Protection ClassClass II
Pollution Degree3 conforming to IEC 60664-1
IP Degree Of ProtectionIP40 conforming to IEC 60529
IK Degree Of ProtectionIK07 conforming to IEC 62262
Ambient Air Temperature For Operation-25…70 °C
Ambient Air Temperature For Storage-50…85 °C
Relative Humidity0…95 %
Operating Altitude0...2000 m without derating
2000 m...5000 m with derating
Write Your Own Review
You're reviewing:Circuit breaker, ComPacT NSX250H, 70kA/415VAC, 3 poles, MicroLogic 2.2M trip unit 220A
Your Rating