Short description of LV848905SP

NEUTRAL CT 400/2000A SENSOR CONDENSED
Country of Origin
United States
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 13 To 15 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
CT neutral or ground fault protection
-  for MTZ2 spare part.
Label :  Masterpact MTZ
-  range :  Masterpact
-  device short name :  TCE
-  product or component type :  external sensor
-  device composition :  3 layer bus sensor
-  device application :  protection
-  range compatibility : 
-  Range Presentation :  Increase power uptime and energy efficiency with the new Masterpact™ MTZ air circuit breaker. Building on the legendary performance, safety, and reliability of the existing Masterpact range, Masterpact MTZ circuit-breaker is future
- ready.
Masterpact MTZ circuit breaker is taking electrical distribution into the "Internet of Things" era. It incorporates communication functionality as well as Class 1 accuracy power/energy measurement to ensure smart operation. Masterpact MTZ connects your electrical switchboard to any building and energy management system. On top of that, you can now use your smart phone as the main HMI to monitor and control Masterpact MTZ, giving you maximum convenience and ease of management.
-  Range Benefits :  http : //masterpactmtz.schneider
- electric.com/
Masterpact MTZ circuit breakers incorporate the latest digital technologies : 
-  Connectivity Ready
-  Precision Ready
-  Upgrade Ready
-  Environment Ready
-  Installation Ready
-  Integration Ready
-  Sustainability Ready
-  Range Application Presentation :  Designed for the protection, measurement and communication of LV electrical networks, specifically motor and generator protection.
Ensure reliability thanks to improved mechanical and electrical performance, even for heavy
- duty applications and in harsh environments.
MAIN SPECIFICATIONS
Contacts Type And Composition400-2000 A
Diameterneutral + earth fault protection
Product Or Component Typeexternal sensor
Device Composition3 layer bus sensor
Device Short NameTCE
EAN133606480919619
RangeMasterpact
Range Compatibility Masterpact MTZ2 circuit breaker
Range NameMasterpact MTZ
COMPLEMENTARY
Current Transformer Typeneutral + earth fault protection
[In] Rated Current400-2000 A
Depth128.1 mm
Device Applicationprotection
Height107.4 mm
Offer Typelow cost
spare part
Provided Equipment1 instruction sheet
Width98.7 mm
OTHER
Poles Descriptionexternal sensor
Write Your Own Review
You're reviewing:CT Neutral or Ground Fault Protection - for MTZ2 Spare Part