External Power Supply Module, Input Voltage 24 V DC To 30 V DC, Output Voltage 24 V DC, Output Current 1 A
Schneider
SKU
SE_LV454440
Model
LV454440
SGD $854.42 All prices inclusive of GST
Short description of LV454440
24VDC POWER SUPPLY AD MODULE 24/30 VDC
Country of Origin
China
external power supply module 24 – 30 V DC
-  24 V
-  1 A.
Label :  Masterpact NT
-  range :  Masterpact
-  product or component type :  external power supply module
-  device application :  power supply
-  range compatibility :  Masterpact NT circuit breaker , Masterpact MTZ3 circuit breaker , PowerPact P circuit breaker , PowerPact L circuit breaker , Masterpact NW circuit breaker , Compact NS circuit breaker , Masterpact MTZ2 circuit breaker , Masterpact MTZ1 circuit breaker , Compact NSX circuit breaker , Compact NSX DC circuit breaker , PowerPact H circuit breaker , PowerPact J circuit breaker , PowerPact Multistandard circuit breaker , PowerPact R circuit breaker
-  accessory / separate part type :  control units accessories,trip unit accessories
-  Range Presentation :  The concentrated know
- how for high current circuit breakers
Masterpact NT circuit breakers are equipped with Micrologic control units that offer built-in power and energy metering in addition to basic or advanced protection functions. The Masterpact NT air circuit breaker is the smallest in the world, featuring compact dimensions in one size from 630 to 1600 A, with breaking capacity from 42 to 150 kA. The range comes with a wide choice of standardized accessories. The universal design of the Masterpact circuit breaker line allows most accessories to be across the entire line. It enables standardization of electrical switchboards by providing peace of mind in terms of choice, installation, and operation.
Specifications : 
-  Rated current :  630 to 1600 A
-  Breaking capacity :  42 to 150 kA at 220/415 V AC
-  Voltage rating :  up to 690 V AC
-  1 unique physical size
-  Draw out and fixed mount
-  3-pole and 4-pole construction
-  Electronic Micrologic control units, integrating current, voltage, power and energy metering enabling energy
- management, earth leakage protection, and other advanced protection or network analysis functions
-  Switch disconnectors version available
-  Optimized range of field
- installable auxiliaries and accessories
-  Different offers complying with different international standards :  IEC 60947, UL489, ANSI/UL1066
-  CCC, EAC and other local certifications
-  Compliance with specifications of marine classification companies :  Bureau Veritas, Lloyd’s Register of Shipping, Det Norske Veritas, etc.
-  Range Benefits :  Masterpact NT circuit breakers contribute to reliability and continuity of service of your electrical installation thanks to : 
Optimized safety
Faultless protection
Increased uptime with improved coordination with Micrologic electronic trip unit adjustability
Complete selectivity and coordination
High resistance to environmental stresses
Integrated monitoring for energy efficiency
Improved uptime with complete monitoring solution in Smart Panels
Seamless integration into power monitoring systems enabling to track energy consumption trends, anticipate potential damage and improve network reliability
Local and remote communication with trip cause (earth leakage, overload, short-circuit) and alarms (earth leakage, overload) allowing proactive operational and energy efficiency
Advanced Micrologic control unit can assist in providing corrective, preventative and predictive maintenance, and energy management to identify potential savings :  energy consumption data, operation follow-up, network monitoring, pre-alarm and alarm events
Seamless installation
Compactness
Standardized range of auxiliaries and accessories
Wide range of online and offline software tools that improve productivity at all stages of your project (Ecoreal, Ecodial, MyPact, Ecoreach)
Masterpact NT is a part of EcoStruxure™ Power – Schneider Electric’s open, interoperable, IoT-enabled system architecture.
-  Range Application Presentation :  General applications in all types of low voltage electrical installations
Suitable in most applications for protection, measurement, monitoring and quality of energy, including generator protection and motor protection, in standard applications and specific applications demanding high performance, including : 
Industry :  mining operations, minerals, metals, and cement production, water & wastewater industry, automotive, food and beverage, etc.
Oil & Gas extraction and processing, Chemicals industries
Data centers infrastructure
Healthcare infrastructure, hospitals
Marine and offshore industry
Infrastructures :  airports, railways, subways, tunnels, power plants, etc.
Buildings :  commercial buildings, hotels, offices
Wind turbines, solar, gensets
Special applications
Navy (Masterpact NT and NW Navy)
UL 489 (Masterpact NT and NW UL 489 listed)
Source-changeover systems (Transferpact) :  service sector (hospital operating rooms, computer rooms, etc.), industry (assembly lines, ship engine rooms, etc.), infrastructures (runway, railway, etc.)
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  24 V
-  1 A.
Label :  Masterpact NT
-  range :  Masterpact
-  product or component type :  external power supply module
-  device application :  power supply
-  range compatibility :  Masterpact NT circuit breaker , Masterpact MTZ3 circuit breaker , PowerPact P circuit breaker , PowerPact L circuit breaker , Masterpact NW circuit breaker , Compact NS circuit breaker , Masterpact MTZ2 circuit breaker , Masterpact MTZ1 circuit breaker , Compact NSX circuit breaker , Compact NSX DC circuit breaker , PowerPact H circuit breaker , PowerPact J circuit breaker , PowerPact Multistandard circuit breaker , PowerPact R circuit breaker
-  accessory / separate part type :  control units accessories,trip unit accessories
-  Range Presentation :  The concentrated know
- how for high current circuit breakers
Masterpact NT circuit breakers are equipped with Micrologic control units that offer built-in power and energy metering in addition to basic or advanced protection functions. The Masterpact NT air circuit breaker is the smallest in the world, featuring compact dimensions in one size from 630 to 1600 A, with breaking capacity from 42 to 150 kA. The range comes with a wide choice of standardized accessories. The universal design of the Masterpact circuit breaker line allows most accessories to be across the entire line. It enables standardization of electrical switchboards by providing peace of mind in terms of choice, installation, and operation.
Specifications : 
-  Rated current :  630 to 1600 A
-  Breaking capacity :  42 to 150 kA at 220/415 V AC
-  Voltage rating :  up to 690 V AC
-  1 unique physical size
-  Draw out and fixed mount
-  3-pole and 4-pole construction
-  Electronic Micrologic control units, integrating current, voltage, power and energy metering enabling energy
- management, earth leakage protection, and other advanced protection or network analysis functions
-  Switch disconnectors version available
-  Optimized range of field
- installable auxiliaries and accessories
-  Different offers complying with different international standards :  IEC 60947, UL489, ANSI/UL1066
-  CCC, EAC and other local certifications
-  Compliance with specifications of marine classification companies :  Bureau Veritas, Lloyd’s Register of Shipping, Det Norske Veritas, etc.
-  Range Benefits :  Masterpact NT circuit breakers contribute to reliability and continuity of service of your electrical installation thanks to : 
Optimized safety
Faultless protection
Increased uptime with improved coordination with Micrologic electronic trip unit adjustability
Complete selectivity and coordination
High resistance to environmental stresses
Integrated monitoring for energy efficiency
Improved uptime with complete monitoring solution in Smart Panels
Seamless integration into power monitoring systems enabling to track energy consumption trends, anticipate potential damage and improve network reliability
Local and remote communication with trip cause (earth leakage, overload, short-circuit) and alarms (earth leakage, overload) allowing proactive operational and energy efficiency
Advanced Micrologic control unit can assist in providing corrective, preventative and predictive maintenance, and energy management to identify potential savings :  energy consumption data, operation follow-up, network monitoring, pre-alarm and alarm events
Seamless installation
Compactness
Standardized range of auxiliaries and accessories
Wide range of online and offline software tools that improve productivity at all stages of your project (Ecoreal, Ecodial, MyPact, Ecoreach)
Masterpact NT is a part of EcoStruxure™ Power – Schneider Electric’s open, interoperable, IoT-enabled system architecture.
-  Range Application Presentation :  General applications in all types of low voltage electrical installations
Suitable in most applications for protection, measurement, monitoring and quality of energy, including generator protection and motor protection, in standard applications and specific applications demanding high performance, including : 
Industry :  mining operations, minerals, metals, and cement production, water & wastewater industry, automotive, food and beverage, etc.
Oil & Gas extraction and processing, Chemicals industries
Data centers infrastructure
Healthcare infrastructure, hospitals
Marine and offshore industry
Infrastructures :  airports, railways, subways, tunnels, power plants, etc.
Buildings :  commercial buildings, hotels, offices
Wind turbines, solar, gensets
Special applications
Navy (Masterpact NT and NW Navy)
UL 489 (Masterpact NT and NW UL 489 listed)
Source-changeover systems (Transferpact) :  service sector (hospital operating rooms, computer rooms, etc.), industry (assembly lines, ship engine rooms, etc.), infrastructures (runway, railway, etc.)
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 24...30 V DC tolerance: +/- 20 % |
Physical Interface | 24 V DC +/-5 % |
Power Supply Output Current | 1 A |
Pressure Sensor Size | 1 A |
Pressure Sensor Type | 24 W |
Product Or Component Type | external power supply module |
Range Of Product | ComPact NS1600b...3200 ComPact NS630b...1600 ComPact NSX100...250 ComPact NSX100...250 DC ComPact NSX400...630 ComPact NSX400...630 DC |
Rated Power In W | 24 W |
Trip Unit Name | Micrologic |
Accessory / Separate Part Type | control units accessories trip unit accessories |
EAN13 | 3606481190925 |
Mounting Support | 35 x 7.5 mm symmetrical DIN rail |
Name Of Test | conducted emissions on the power line conforming to EN 61000-6-3 electrostatic discharges conforming to EN/IEC 61000-4-2 induced electromagnetic field conforming to EN/IEC 61000-4-6 magnetic field conforming to EN 61000-4-8 primary outage conforming to IEC 61000-4-29 radiated electromagnetic field conforming to EN/IEC 61000-4-3 radiated emissions conforming to EN 61000-6-3 rapid transient conforming to IEC 61000-4-4 surge conforming to EN/IEC 61000-4-5 |
Power Supply Type | regulated switch mode |
Range | Masterpact |
Range Compatibility | ComPact NS1600b...3200 ComPact NS630b...1600 ComPact NSX ComPact NSX DC Masterpact MTZ MasterPact NT Masterpact NW PowerPact H PowerPact J PowerPact L PowerPact P PowerPact R |
Range Name | Masterpact NT |
COMPLEMENTARY | |
Output Voltage | 24 V DC +/-5 % |
Compatibility Code | CB_EXTERNAL_POWERSUPPLY |
Connections - Terminals | screw type terminals, connection capacity: 1 x 0.2...1 x 4 mm² AWG 24...AWG 12 screw type terminals, connection capacity: 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16 |
Depth | 67.5 mm |
Device Application | power supply |
Efficiency | 80 % |
Height | 90 mm |
Holding Time | >= 20 ms 24...30 V DC |
Input Voltage Limits | 19.2...36 V DC |
Inrush Current | 40 A 2 ms |
Marking | CE EAC UL |
Operating Position | horizontal |
Output Protection Type | against overload, protection technology: manual reset against overvoltage, protection technology: 30...32 V, manual reset against short-circuits, protection technology: manual reset thermal, protection technology: automatic reset |
Permissible Temporary Current Boost | 1.5 A (200 ms) |
Power Dissipation In W | 4.5 W |
Status LED | 1 LED (green)output voltage |
Width | 108 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -50-85 °C |
Dielectric Strength | 1840 V between output and ground 3680 V between input and ground 3680 V between input and output |
Environmental Characteristic | EMC conforming to EN/IEC 61000-6-2 EMC conforming to EN/IEC 61000-6-3 safety conforming to IEC 62477-1 safety conforming to SELV |
IP Degree Of Protection | IP2x (connection terminals) conforming to EN/IEC 60529 IP3x (housing) conforming to EN/IEC 60529 IP4X (front face) conforming to EN/IEC 60529 |
Operating Altitude | 0...2000 m |
Overvoltage Category | III conforming to IEC 62477-1 III conforming to UL 61010-1 |
Relative Humidity | 0-95 % during operation 0-95 % in storage |
Standards | IEC 62477-1 UL 61010-1 |
OTHER | |
Earth Leakage Current | Micrologic |
Poles Description | external power supply module |
[Us] Rated Supply Voltage | 24...30 V DC tolerance: +/- 20 % |