Loading...

Miniature Circuit-breaker, Acti9 C120N, 2P, 100 A, C Curve, 10000 A (IEC 60898-1), 10 KA (IEC 60947-2)

Schneider
SKU
SE_A9N18362
Model
A9N18362
SGD $51.23 All prices inclusive of GST

Short description of A9N18362

Acti9 C120N MCB 2P C 100A 10000A 415V
Country of Origin
China
-
+

UOM: Piece

In stock
In Stock 4
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
C120N
-  circuit breaker
-  2P
-  100A
-  C curve.
Label :  C120
-  range of product :  C120
-  [In] rated current :  100 A at 30 °C
-  network type :  AC
-  trip unit technology :  thermal
- magnetic
-  curve code :  C
-  breaking capacity code :  N
-  breaking capacity :  N/A, N/A, N/A, N/A, N/A
-  range :  Acti 9
-  suitability for isolation :  yes conforming to IEC 60947-2
-  product name :  C120
-  product or component type :  miniature circuit-breaker
-  device short name :  C120N
-  device application :  distribution
-  poles description :  2P
-  number of protected poles :  2
-  neutral position :  left
-  Range Presentation- 
-  Range Benefits :  Quality without boundaries
The C120 circuit-breaker, derived directly from the C60, is recognised in over 100 countries for its quality and the breadth of its range, making it an indispensable component for developing low voltage installations with complete peace of mind.
-  Range Application Presentation : 
-  Protection of electrical circuits in all industrial and tertiary buildings

This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS
Breaking Capacity10 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1
20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking Capacity CodeN
Contacts Type And Composition100 A at 30 °C
Control Typetoggle
Product Or Component Typeminiature circuit-breaker
Range Of ProductC120
[Ie] Rated Operational Currenttoggle
[Ue] Rated Operational Voltage<= 250 V DC
220...240 V AC 50/60 Hz
230...400 V AC 50/60 Hz
380...415 V AC 50/60 Hz
440 V AC 50/60 Hz
Curve CodeC
Device Short NameC120N
EAN133606480379369
Mounting Support35 mm symmetrical DIN rail
Network TypeAC
Neutral Positionleft
Number Of Protected Poles2
RangeActi 9
Range NameActi 9 C120
Suitability For Isolationyes conforming to IEC 60947-2
Trip Unit Technologythermal-magnetic
COMPLEMENTARY
Communication Network Type<= 250 V DC
220...240 V AC 50/60 Hz
230...400 V AC 50/60 Hz
380...415 V AC 50/60 Hz
440 V AC 50/60 Hz
Current Transformer TypeN
Interlocked Device10 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1
20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Product NameC120
[Ics] Rated Service Breaking Capacity10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz
4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz
7500 A 75 % conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz
[In] Rated Current100 A at 30 °C
9 Mm Pitches6
Colourwhite
Comb Busbar And Distribution Block Compatibilityno
Compatibility CodeC120
Connections - Terminalstunnel type terminals1.5-35 mm² flexible
tunnel type terminals1-50 mm² rigid
Contact Position Indicatoryes
Depth73 mm
Device Applicationdistribution
Earth-leakage Protectionseparate block
Electrical Durability5000 cycles conforming to IEC 60947-2
Height81 mm
Limitation Class3 conforming to EN/IEC 60947-2
Local SignallingON/OFF indication
Magnetic Tripping Limit5...10 x In
Market Segmentresidential
small commercial
Mechanical Durability20000 cycles
Mounting Modeclip-on
Net Weight0.41 kg
Network Frequency50/60 Hz
Tightening Torque3.5-3.5 N.m
Width54 mm
Wire Stripping Length15 mm
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to EN/IEC 60947-2
[Ui] Rated Insulation Voltage500 V AC 50/60 Hz conforming to EN/IEC 60947-2
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-40-85 °C
IP Degree Of ProtectionIP20 conforming to IEC 60529
Operating Altitude2000 m
Overvoltage CategoryIV
Pollution Degree3 conforming to IEC 60947-2
Product CertificationsEAC
Relative Humidity95-95 % at 55-55 °C
StandardsEN/IEC 60898-1
EN/IEC 60947-2
Tropicalisation2 conforming to IEC 60068-1
OTHER
Poles Description2P
[Us] Rated Supply VoltageC120
Write Your Own Review
You're reviewing:Miniature Circuit-breaker, Acti9 C120N, 2P, 100 A, C Curve, 10000 A (IEC 60898-1), 10 KA (IEC 60947-2)
Your Rating