Miniature Circuit-breaker, Acti9 C120N, 2P, 80 A, B Curve, 10000 A (IEC 60898-1), 10 KA (IEC 60947-2)
Schneider
SKU
SE_A9N18345
Model
A9N18345
SGD $41.82 All prices inclusive of GST
Short description of A9N18345
Acti9 C120N MCB 2P B 80A 10000A 415V
Country of Origin
China
C120N
-  circuit breaker
-  2P
-  80A
-  B curve.
Label :  C120
-  range of product :  C120
-  [In] rated current :  80 A at 30 °C
-  network type :  AC
-  trip unit technology :  thermal
- magnetic
-  curve code :  B
-  breaking capacity code :  N
-  breaking capacity :  N/A, N/A, N/A, N/A, N/A
-  range :  Acti 9
-  suitability for isolation :  yes conforming to IEC 60947-2
-  product name :  C120
-  product or component type :  miniature circuit-breaker
-  device short name :  C120N
-  device application :  distribution
-  poles description :  2P
-  number of protected poles :  2
-  neutral position :  left
-  Range Presentation- 
-  Range Benefits :  Quality without boundaries
The C120 circuit-breaker, derived directly from the C60, is recognised in over 100 countries for its quality and the breadth of its range, making it an indispensable component for developing low voltage installations with complete peace of mind.
-  Range Application Presentation : 
-  Protection of electrical circuits in all industrial and tertiary buildings
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  circuit breaker
-  2P
-  80A
-  B curve.
Label :  C120
-  range of product :  C120
-  [In] rated current :  80 A at 30 °C
-  network type :  AC
-  trip unit technology :  thermal
- magnetic
-  curve code :  B
-  breaking capacity code :  N
-  breaking capacity :  N/A, N/A, N/A, N/A, N/A
-  range :  Acti 9
-  suitability for isolation :  yes conforming to IEC 60947-2
-  product name :  C120
-  product or component type :  miniature circuit-breaker
-  device short name :  C120N
-  device application :  distribution
-  poles description :  2P
-  number of protected poles :  2
-  neutral position :  left
-  Range Presentation- 
-  Range Benefits :  Quality without boundaries
The C120 circuit-breaker, derived directly from the C60, is recognised in over 100 countries for its quality and the breadth of its range, making it an indispensable component for developing low voltage installations with complete peace of mind.
-  Range Application Presentation : 
-  Protection of electrical circuits in all industrial and tertiary buildings
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Breaking Capacity | 10 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
Breaking Capacity Code | N |
Contacts Type And Composition | 80 A at 30 °C |
Control Type | toggle |
Product Or Component Type | miniature circuit-breaker |
Range Of Product | C120 |
[Ie] Rated Operational Current | toggle |
[Ue] Rated Operational Voltage | <= 250 V DC 220...240 V AC 50/60 Hz 230...400 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz |
Curve Code | B |
Device Short Name | C120N |
EAN13 | 3606480379192 |
Mounting Support | 35 mm symmetrical DIN rail |
Network Type | AC |
Neutral Position | left |
Number Of Protected Poles | 2 |
Range | Acti 9 |
Range Name | Acti 9 C120 |
Suitability For Isolation | yes conforming to IEC 60947-2 |
Trip Unit Technology | thermal-magnetic |
COMPLEMENTARY | |
Communication Network Type | <= 250 V DC 220...240 V AC 50/60 Hz 230...400 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz |
Current Transformer Type | N |
Interlocked Device | 10 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
Product Name | C120 |
[Ics] Rated Service Breaking Capacity | 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 7500 A 75 % conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz |
[In] Rated Current | 80 A at 30 °C |
9 Mm Pitches | 6 |
Colour | white |
Comb Busbar And Distribution Block Compatibility | yes |
Compatibility Code | C120 |
Connections - Terminals | tunnel type terminals1.5-35 mm² flexible tunnel type terminals1-50 mm² rigid |
Contact Position Indicator | yes |
Depth | 73 mm |
Device Application | distribution |
Earth-leakage Protection | separate block |
Electrical Durability | 5000 cycles conforming to IEC 60947-2 |
Height | 81 mm |
Limitation Class | 3 conforming to EN/IEC 60947-2 |
Local Signalling | ON/OFF indication |
Magnetic Tripping Limit | 3...5 x In |
Market Segment | residential small commercial |
Mechanical Durability | 20000 cycles |
Mounting Mode | clip-on |
Net Weight | 0.41 kg |
Network Frequency | 50/60 Hz |
Tightening Torque | 3.5-3.5 N.m |
Width | 54 mm |
Wire Stripping Length | 15 mm |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to EN/IEC 60947-2 |
[Ui] Rated Insulation Voltage | 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -40-85 °C |
IP Degree Of Protection | IP20 conforming to IEC 60529 |
Operating Altitude | 2000 m |
Overvoltage Category | IV |
Pollution Degree | 3 conforming to IEC 60947-2 |
Product Certifications | EAC |
Relative Humidity | 95-95 % at 55-55 °C |
Standards | EN/IEC 60898-1 EN/IEC 60947-2 |
Tropicalisation | 2 conforming to IEC 60068-1 |
OTHER | |
Poles Description | 2P |
[Us] Rated Supply Voltage | C120 |
Write Your Own Review