Loading...

A9F85304 - Miniature Circuit-breaker, Acti9 IC60H, 3P, 4 A, D Curve, 10000 A (IEC 60898-1), 70 KA (IEC 60947-2).

Schneider
SKU
SE_A9F85304
Model
A9F85304
SGD $119.34 All prices inclusive of GST

Short description of A9F85304

A9F85304. Miniature Circuit Breakers up to 63 A
Country of Origin
France
-
+

UOM: Piece

In stock
In Stock 0

Minimum Order Quantity: 4

Backorder Leadtime: 15 To 17 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
device application : Distribution
-  range : Acti 9
-  product name : Acti 9 iC60
-  product or component type : Miniature circuit-breaker
-  device short name : IC60H
-  poles description : 3P
-  number of protected poles : 3
-  [In] rated current : 4 A
-  network type : ACDC
-  trip unit technology : Thermal
- magnetic
-  curve code : D
-  breaking capacity : 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-115 kA Icu at - utilisation category : Category A conforming to EN 60947-2Category A conforming to IEC 60947-2
-  suitability for isolation : Yes conforming to EN 60898-1Yes conforming to EN 60947-2Yes conforming to IEC 60898-1Yes conforming to IEC 60947-2
-  standards : IEC 60898-1IEC 60947-2EN 60947-2EN 60898-1

This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS
Breaking Capacity10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
15 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2
70 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking Capacity CodeH
Contacts Type And Composition4 A
Control Typetoggle
Product Or Component Typeminiature circuit-breaker
Range Of ProductiC60
[Ie] Rated Operational Currenttoggle
[Ue] Rated Operational Voltage12...133 V AC 50/60 Hz
125...180 V DC
220...240 V AC 50/60 Hz
380...415 V AC 50/60 Hz
400 V AC 50/60 Hz
440 V AC 50/60 Hz
Curve CodeD
Device Short NameiC60H
Mounting SupportDIN rail
Network TypeAC
DC
Number Of Protected Poles3
RangeActi 9
Range NameActi 9 iC60
Suitability For Isolationyes conforming to EN 60898-1
yes conforming to EN 60947-2
yes conforming to IEC 60898-1
yes conforming to IEC 60947-2
Trip Unit Technologythermal-magnetic
Utilisation Categorycategory A conforming to EN 60947-2
category A conforming to IEC 60947-2
COMPLEMENTARY
Communication Network Type12...133 V AC 50/60 Hz
125...180 V DC
220...240 V AC 50/60 Hz
380...415 V AC 50/60 Hz
400 V AC 50/60 Hz
440 V AC 50/60 Hz
Current Transformer TypeH
Interlocked Device10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
15 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2
70 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Product NameActi9 iC60
[Ics] Rated Service Breaking Capacity15 kA 100 % conforming to EN 60947-2 - 125...180 V DC
15 kA 100 % conforming to IEC 60947-2 - 125...180 V DC
70 kA 100 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
70 kA 100 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
70 kA 100 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
70 kA 100 % conforming to EN 60947-2 - 440 V AC 50/60 Hz
70 kA 100 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
70 kA 100 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
70 kA 100 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
70 kA 100 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz
7500 A 75 % conforming to EN 60898-1 - 400 V AC 50/60 Hz
7500 A 75 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz
[In] Rated Current4 A
9 Mm Pitches6
Colourwhite
Comb Busbar And Distribution Block Compatibilitytop or bottom: YES
Compatibility CodeiC60
Connections - Terminalssingle terminal (top or bottom) 1-16 mm² flexible
single terminal (top or bottom) 1-25 mm² rigid
Contact Position Indicatoryes
Depth78.5 mm
Device Applicationdistribution
Earth-leakage Protectionseparate block
Electrical Durability10000 cycles
Height85 mm
Limitation Class3 conforming to EN 60898-1
3 conforming to IEC 60898-1
Local Signallingtrip indicator
Magnetic Tripping Limit12 x In +/- 20 %
Market Segmentsmall commercial
Mechanical Durability20000 cycles
Mounting Modefixed
Net Weight0.375 kg
Network Frequency50/60 Hz
Tightening Torque2-2 N.m top or bottom
Width54 mm
Wire Stripping Length14 mm for top or bottom connection
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
[Ui] Rated Insulation Voltage500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
ENVIRONMENT
Ambient Air Temperature For Operation-35-70 °C
Ambient Air Temperature For Storage-40-85 °C
IP Degree Of ProtectionIP20 conforming to EN 60529
IP20 conforming to IEC 60529
Operating Altitude0...2000 m
Overvoltage CategoryIV
Pollution Degree3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Relative Humidity95-95 % at 55-55 °C
StandardsEN 60898-1
EN 60947-2
IEC 60898-1
IEC 60947-2
Tropicalisation2 conforming to IEC 60068-1
OTHER
Poles Description3P
[Us] Rated Supply VoltageiC60
Write Your Own Review
You're reviewing:A9F85304 - Miniature Circuit-breaker, Acti9 IC60H, 3P, 4 A, D Curve, 10000 A (IEC 60898-1), 70 KA (IEC 60947-2).
Your Rating