Miniature Circuit-breaker, Acti9 IC60H, 2P, 40 A, D Curve, 10000 A (IEC 60898-1), 15 KA (IEC 60947-2)
Schneider
SKU
SE_A9F85240
Model
A9F85240
SGD $37.15 All prices inclusive of GST
Short description of A9F85240
Acti9 iC60H 2P D 40A MCB
Country of Origin
France
iC60H
-  miniature circuit breaker
-  2P
-  40A
-  D curve.
Label :  Acti 9 iC60
-  device application :  distribution
-  [In] rated current :  40 A
-  network type :  AC,DC
-  trip unit technology :  thermal
- magnetic
-  curve code :  D
-  breaking capacity code :  H
-  range :  Acti 9
-  breaking capacity :  N/A, N/A, N/A, N/A, N/A, N/A, N/A
-  utilisation category :  category A conforming to EN 60947-2, category A conforming to IEC 60947-2
-  suitability for isolation :  yes conforming to EN 60898-1, yes conforming to EN 60947-2, yes conforming to IEC 60898-1, yes conforming to IEC 60947-2
-  range of product :  iC60
-  standards :  EN 60898-1,IEC 60947-2,IEC 60898-1,EN 60947-2
-  product name :  Acti 9 iC60
-  product or component type :  miniature circuit-breaker
-  device short name :  iC60H
-  poles description :  2P
-  number of protected poles :  2
-  Range Presentation :  With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
-  VisiSafe  :  for safe operation and maintenance work on circuits.
-  Class-2 insulation  :  continuous safety for operators and unqualified personnel.
-  VisiTrip  :  detects faulty Miniature Circuit
- Breaker outgoers quickly and reduces intervention time.
-  Add-on fully immune earth leakage protection devices  :  better continuity of service, especially in polluted environments and networks.
-  Nominal current :  1 to 63 A
-  Large choice of breaking capacities up to 100 kA and tripping curves :  B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
-  Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
-  Suitable for isolation in accordance with industrial standard IEC 60947
-  Operating voltage :  up to 440 V AC, insulation voltage :  500 V
-  Optional add-on earth leakage modules :  iC60 Vigi,
-  Optional auxiliaries :  indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
-  For more information click here
-  Range Benefits : 
-  The new reference in final distribution,
-  Absolute safety of circuit protection with VisiSafe,
-  Greater continuity of service with VisiTrip,
-  Simple to choose with meaningful part numbers,
-  Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
-  Environmentally friendly with 100% recyclable & recoverable materials.
-  Range Application Presentation :  Low-voltage final distribution
-  Protection of electrical circuits in all industrial and commercial buildings,
-  All applications, especially in polluted environments and networks,
-  Motor circuit protection,
-  DC current circuit protection.
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  miniature circuit breaker
-  2P
-  40A
-  D curve.
Label :  Acti 9 iC60
-  device application :  distribution
-  [In] rated current :  40 A
-  network type :  AC,DC
-  trip unit technology :  thermal
- magnetic
-  curve code :  D
-  breaking capacity code :  H
-  range :  Acti 9
-  breaking capacity :  N/A, N/A, N/A, N/A, N/A, N/A, N/A
-  utilisation category :  category A conforming to EN 60947-2, category A conforming to IEC 60947-2
-  suitability for isolation :  yes conforming to EN 60898-1, yes conforming to EN 60947-2, yes conforming to IEC 60898-1, yes conforming to IEC 60947-2
-  range of product :  iC60
-  standards :  EN 60898-1,IEC 60947-2,IEC 60898-1,EN 60947-2
-  product name :  Acti 9 iC60
-  product or component type :  miniature circuit-breaker
-  device short name :  iC60H
-  poles description :  2P
-  number of protected poles :  2
-  Range Presentation :  With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
-  VisiSafe  :  for safe operation and maintenance work on circuits.
-  Class-2 insulation  :  continuous safety for operators and unqualified personnel.
-  VisiTrip  :  detects faulty Miniature Circuit
- Breaker outgoers quickly and reduces intervention time.
-  Add-on fully immune earth leakage protection devices  :  better continuity of service, especially in polluted environments and networks.
-  Nominal current :  1 to 63 A
-  Large choice of breaking capacities up to 100 kA and tripping curves :  B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
-  Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
-  Suitable for isolation in accordance with industrial standard IEC 60947
-  Operating voltage :  up to 440 V AC, insulation voltage :  500 V
-  Optional add-on earth leakage modules :  iC60 Vigi,
-  Optional auxiliaries :  indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
-  For more information click here
-  Range Benefits : 
-  The new reference in final distribution,
-  Absolute safety of circuit protection with VisiSafe,
-  Greater continuity of service with VisiTrip,
-  Simple to choose with meaningful part numbers,
-  Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
-  Environmentally friendly with 100% recyclable & recoverable materials.
-  Range Application Presentation :  Low-voltage final distribution
-  Protection of electrical circuits in all industrial and commercial buildings,
-  All applications, especially in polluted environments and networks,
-  Motor circuit protection,
-  DC current circuit protection.
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Breaking Capacity | 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 15 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 42 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
Breaking Capacity Code | H |
Contacts Type And Composition | 40 A |
Control Type | toggle |
Product Or Component Type | miniature circuit-breaker |
Range Of Product | iC60 |
[Ie] Rated Operational Current | toggle |
[Ue] Rated Operational Voltage | 12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 400 V AC 50/60 Hz 440 V AC 50/60 Hz 72...125 V DC |
Curve Code | D |
Device Short Name | iC60H |
EAN13 | 3606480083235 |
Mounting Support | DIN rail |
Network Type | AC DC |
Number Of Protected Poles | 2 |
Range | Acti 9 |
Range Name | Acti 9 iC60 |
Suitability For Isolation | yes conforming to EN 60898-1 yes conforming to EN 60947-2 yes conforming to IEC 60898-1 yes conforming to IEC 60947-2 |
Trip Unit Technology | thermal-magnetic |
Utilisation Category | category A conforming to EN 60947-2 category A conforming to IEC 60947-2 |
COMPLEMENTARY | |
Communication Network Type | 12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 400 V AC 50/60 Hz 440 V AC 50/60 Hz 72...125 V DC |
Current Transformer Type | H |
Interlocked Device | 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 15 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 42 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
Product Name | Acti9 iC60 |
[Ics] Rated Service Breaking Capacity | 15 kA 100 % conforming to EN 60947-2 - 72...125 V DC 15 kA 100 % conforming to IEC 60947-2 - 72...125 V DC 15 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 15 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 21 kA 50 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 21 kA 50 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 5 kA 50 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 5 kA 50 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA 50 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 7.5 kA 50 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 7500 A 75 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 7500 A 75 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz |
[In] Rated Current | 40 A |
9 Mm Pitches | 4 |
Colour | white |
Comb Busbar And Distribution Block Compatibility | top or bottom: YES |
Compatibility Code | iC60 |
Connections - Terminals | single terminal (top or bottom) 1-25 mm² flexible single terminal (top or bottom) 1-35 mm² rigid |
Contact Position Indicator | yes |
Depth | 78.5 mm |
Device Application | distribution |
Earth-leakage Protection | separate block |
Electrical Durability | 10000 cycles |
Height | 85 mm |
Limitation Class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
Local Signalling | trip indicator |
Magnetic Tripping Limit | 12 x In +/- 20 % |
Market Segment | small commercial |
Mechanical Durability | 20000 cycles |
Mounting Mode | fixed |
Net Weight | 0.25 kg |
Network Frequency | 50/60 Hz |
Tightening Torque | 3.5-3.5 N.m top or bottom |
Width | 36 mm |
Wire Stripping Length | 14 mm for top or bottom connection |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
[Ui] Rated Insulation Voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -35-70 °C |
Ambient Air Temperature For Storage | -40-85 °C |
IP Degree Of Protection | IP20 conforming to EN 60529 IP20 conforming to IEC 60529 |
Operating Altitude | 0...2000 m |
Overvoltage Category | IV |
Pollution Degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
Relative Humidity | 95-95 % at 55-55 °C |
Standards | EN 60898-1 EN 60947-2 IEC 60898-1 IEC 60947-2 |
Tropicalisation | 2 conforming to IEC 60068-1 |
OTHER | |
Poles Description | 2P |
[Us] Rated Supply Voltage | iC60 |
Write Your Own Review