IC60N - Miniature Circuit Breaker - 1P - 6A - C Curve
Schneider
SKU
SE_A9F74106
Model
A9F74106
SGD $5.43 All prices inclusive of GST
Short description of A9F74106
Acti9 iC60N 1P C 6A MCB
Country of Origin
India
iC60N
-  miniature circuit breaker
-  1P
-  6A
-  C curve.
Label :  Acti 9 iC60
-  device application :  distribution
-  [In] rated current :  6 A
-  network type :  AC,DC
-  trip unit technology :  thermal
- magnetic
-  curve code :  C
-  breaking capacity code :  N
-  range :  Acti 9
-  breaking capacity :  N/A, N/A, N/A, N/A, N/A, N/A
-  utilisation category :  category A conforming to EN 60947-2, category A conforming to IEC 60947-2
-  suitability for isolation :  yes conforming to EN 60898-1, yes conforming to EN 60947-2, yes conforming to IEC 60898-1, yes conforming to IEC 60947-2
-  range of product :  iC60
-  standards :  IEC 60947-2,EN 60898-1,IEC 60898-1,EN 60947-2
-  product name :  Acti 9 iC60
-  product or component type :  miniature circuit-breaker
-  device short name :  iC60N
-  poles description :  1P
-  number of protected poles :  1
-  Range Presentation :  With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
-  VisiSafe  :  for safe operation and maintenance work on circuits.
-  Class-2 insulation  :  continuous safety for operators and unqualified personnel.
-  VisiTrip  :  detects faulty Miniature Circuit
- Breaker outgoers quickly and reduces intervention time.
-  Add-on fully immune earth leakage protection devices  :  better continuity of service, especially in polluted environments and networks.
-  Nominal current :  1 to 63 A
-  Large choice of breaking capacities up to 100 kA and tripping curves :  B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
-  Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
-  Suitable for isolation in accordance with industrial standard IEC 60947
-  Operating voltage :  up to 440 V AC, insulation voltage :  500 V
-  Optional add-on earth leakage modules :  iC60 Vigi,
-  Optional auxiliaries :  indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
-  For more information click here
-  Range Benefits : 
-  The new reference in final distribution,
-  Absolute safety of circuit protection with VisiSafe,
-  Greater continuity of service with VisiTrip,
-  Simple to choose with meaningful part numbers,
-  Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
-  Environmentally friendly with 100% recyclable & recoverable materials.
-  Range Application Presentation :  Low-voltage final distribution
-  Protection of electrical circuits in all industrial and commercial buildings,
-  All applications, especially in polluted environments and networks,
-  Motor circuit protection,
-  DC current circuit protection.
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  miniature circuit breaker
-  1P
-  6A
-  C curve.
Label :  Acti 9 iC60
-  device application :  distribution
-  [In] rated current :  6 A
-  network type :  AC,DC
-  trip unit technology :  thermal
- magnetic
-  curve code :  C
-  breaking capacity code :  N
-  range :  Acti 9
-  breaking capacity :  N/A, N/A, N/A, N/A, N/A, N/A
-  utilisation category :  category A conforming to EN 60947-2, category A conforming to IEC 60947-2
-  suitability for isolation :  yes conforming to EN 60898-1, yes conforming to EN 60947-2, yes conforming to IEC 60898-1, yes conforming to IEC 60947-2
-  range of product :  iC60
-  standards :  IEC 60947-2,EN 60898-1,IEC 60898-1,EN 60947-2
-  product name :  Acti 9 iC60
-  product or component type :  miniature circuit-breaker
-  device short name :  iC60N
-  poles description :  1P
-  number of protected poles :  1
-  Range Presentation :  With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
-  VisiSafe  :  for safe operation and maintenance work on circuits.
-  Class-2 insulation  :  continuous safety for operators and unqualified personnel.
-  VisiTrip  :  detects faulty Miniature Circuit
- Breaker outgoers quickly and reduces intervention time.
-  Add-on fully immune earth leakage protection devices  :  better continuity of service, especially in polluted environments and networks.
-  Nominal current :  1 to 63 A
-  Large choice of breaking capacities up to 100 kA and tripping curves :  B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
-  Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
-  Suitable for isolation in accordance with industrial standard IEC 60947
-  Operating voltage :  up to 440 V AC, insulation voltage :  500 V
-  Optional add-on earth leakage modules :  iC60 Vigi,
-  Optional auxiliaries :  indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
-  For more information click here
-  Range Benefits : 
-  The new reference in final distribution,
-  Absolute safety of circuit protection with VisiSafe,
-  Greater continuity of service with VisiTrip,
-  Simple to choose with meaningful part numbers,
-  Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
-  Environmentally friendly with 100% recyclable & recoverable materials.
-  Range Application Presentation :  Low-voltage final distribution
-  Protection of electrical circuits in all industrial and commercial buildings,
-  All applications, especially in polluted environments and networks,
-  Motor circuit protection,
-  DC current circuit protection.
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Breaking Capacity | 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
Breaking Capacity Code | N |
Contacts Type And Composition | 6 A |
Control Type | toggle |
Product Or Component Type | miniature circuit-breaker |
Range Of Product | iC60 |
[Ie] Rated Operational Current | toggle |
[Ue] Rated Operational Voltage | 100...133 V AC 50/60 Hz 12...60 V AC 50/60 Hz 12...60 V DC 220...240 V AC 50/60 Hz 230 V AC 50/60 Hz 72 V DC |
Curve Code | C |
Device Short Name | IC60N |
EAN13 | 3606480079450 |
Mounting Support | DIN rail |
Network Type | AC DC |
Number Of Protected Poles | 1 |
Range | Acti 9 |
Range Name | Acti 9 iC60 |
Suitability For Isolation | yes conforming to EN 60898-1 yes conforming to EN 60947-2 yes conforming to IEC 60898-1 yes conforming to IEC 60947-2 |
Trip Unit Technology | thermal-magnetic |
Utilisation Category | category A conforming to EN 60947-2 category A conforming to IEC 60947-2 |
COMPLEMENTARY | |
Communication Network Type | 100...133 V AC 50/60 Hz 12...60 V AC 50/60 Hz 12...60 V DC 220...240 V AC 50/60 Hz 230 V AC 50/60 Hz 72 V DC |
Current Transformer Type | N |
Interlocked Device | 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
Product Name | Acti9 iC60 |
[Ics] Rated Service Breaking Capacity | 10 kA 100 % conforming to EN 60947-2 - 72 V DC 10 kA 100 % conforming to IEC 60947-2 - 72 V DC 15 kA 100 % conforming to EN 60947-2 - 12...60 V DC 15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC 15 kA 75 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz 27 kA 75 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz |
[In] Rated Current | 6 A |
9 Mm Pitches | 2 |
Colour | white |
Comb Busbar And Distribution Block Compatibility | top or bottom: YES |
Compatibility Code | iC60 |
Connections - Terminals | single terminal (top or bottom) 1-16 mm² flexible single terminal (top or bottom) 1-25 mm² rigid |
Contact Position Indicator | yes |
Depth | 78.5 mm |
Device Application | distribution |
Earth-leakage Protection | without |
Electrical Durability | 10000 cycles |
Height | 85 mm |
Limitation Class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
Local Signalling | trip indicator |
Magnetic Tripping Limit | 8 x In +/- 20 % |
Mechanical Durability | 20000 cycles |
Mounting Mode | fixed |
Net Weight | 0.215 kg |
Network Frequency | 50/60 Hz |
Tightening Torque | 2-2 N.m top or bottom |
Width | 18 mm |
Wire Stripping Length | 14 mm for top or bottom connection |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
[Ui] Rated Insulation Voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -35-70 °C |
Ambient Air Temperature For Storage | -40-85 °C |
IP Degree Of Protection | IP20 conforming to EN 60529 IP20 conforming to IEC 60529 |
Operating Altitude | 0...2000 m |
Overvoltage Category | IV |
Pollution Degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
Relative Humidity | 95-95 % at 55-55 °C |
Standards | EN 60898-1 EN 60947-2 IEC 60898-1 IEC 60947-2 |
Tropicalisation | 2 conforming to IEC 60068-1 |
OTHER | |
Poles Description | 1P |
[Us] Rated Supply Voltage | iC60 |
Product Recommendation
- IC60N - Miniature Circuit Breaker - 1P - 3A - C CurveSchneider SKU: SE_A9F74103 Model: A9F74103SGD $24.51 All prices inclusive of GST
- IC60N - Miniature Circuit Breaker - 2P - 10A - C CurveSchneider SKU: SE_A9F74210 Model: A9F74210SGD $23.83 All prices inclusive of GST
- Harmony XB4, Illuminated Push Button Head, Metal, Flush, Red, Ø22, Spring Return, Plain Lens Integral LED.Schneider SKU: SE_ZB4BW343 Model: ZB4BW343SGD $12.09 All prices inclusive of GST
- IC60N - Miniature Circuit Breaker - 2P - 6A - C CurveSchneider SKU: SE_A9F74206 Model: A9F74206SGD $23.83 All prices inclusive of GST
Write Your Own Review