Loading...

Miniature Circuit-breaker, Acti9 IC60N, 2P, 4 A, B Curve, 6000 A (IEC 60898-1), 50 KA (IEC 60947-2)

Schneider
SKU
SE_A9F73204
Model
A9F73204
SGD $63.86 All prices inclusive of GST

Short description of A9F73204

Acti9 iC60N 2P B 4A MCB
Country of Origin
India
-
+

UOM: Piece

In stock
In Stock 20
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
iC60N
-  miniature circuit breaker
-  2P
-  4A
-  B curve.
Label :  Acti 9 iC60
-  device application :  distribution
-  [In] rated current :  4 A
-  network type :  DC,AC
-  trip unit technology :  thermal
- magnetic
-  curve code :  B
-  breaking capacity code :  N
-  range :  Acti 9
-  breaking capacity :  N/A, N/A, N/A, N/A, N/A, N/A, N/A
-  utilisation category :  category A conforming to EN 60947-2, category A conforming to IEC 60947-2
-  suitability for isolation :  yes conforming to EN 60898-1, yes conforming to EN 60947-2, yes conforming to IEC 60898-1, yes conforming to IEC 60947-2
-  range of product :  iC60
-  standards :  IEC 60898-1,IEC 60947-2,EN 60947-2,EN 60898-1
-  product name :  Acti 9 iC60
-  product or component type :  miniature circuit-breaker
-  device short name :  iC60N
-  poles description :  2P
-  number of protected poles :  2
-  Range Presentation :  With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
-  VisiSafe  :  for safe operation and maintenance work on circuits.
-  Class-2 insulation  :  continuous safety for operators and unqualified personnel.
-  VisiTrip  :  detects faulty Miniature Circuit
- Breaker outgoers quickly and reduces intervention time.
-  Add-on fully immune earth leakage protection devices  :  better continuity of service, especially in polluted environments and networks.
-  Nominal current :  1 to 63 A
-  Large choice of breaking capacities up to 100 kA and tripping curves :  B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
-  Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
-  Suitable for isolation in accordance with industrial standard IEC 60947
-  Operating voltage :  up to 440 V AC, insulation voltage :  500 V
-  Optional add-on earth leakage modules :  iC60 Vigi,
-  Optional auxiliaries :  indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
-  For more information click here
-  Range Benefits : 
-  The new reference in final distribution,
-  Absolute safety of circuit protection with VisiSafe,
-  Greater continuity of service with VisiTrip,
-  Simple to choose with meaningful part numbers,
-  Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
-  Environmentally friendly with 100% recyclable & recoverable materials.
-  Range Application Presentation :  Low-voltage final distribution
-  Protection of electrical circuits in all industrial and commercial buildings,
-  All applications, especially in polluted environments and networks,
-  Motor circuit protection,
-  DC current circuit protection.

This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS
Breaking Capacity10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking Capacity CodeN
Contacts Type And Composition4 A
Control Typetoggle
Product Or Component Typeminiature circuit-breaker
Range Of ProductiC60
[Ie] Rated Operational Currenttoggle
[Ue] Rated Operational Voltage12...133 V AC 50/60 Hz
220...240 V AC 50/60 Hz
380...415 V AC 50/60 Hz
400 V AC 50/60 Hz
440 V AC 50/60 Hz
72...125 V DC
Curve CodeB
Device Short NameIC60N
EAN133606480080050
Mounting SupportDIN rail
Network TypeAC
DC
Number Of Protected Poles2
RangeActi 9
Range NameActi 9 iC60
Suitability For Isolationyes conforming to EN 60898-1
yes conforming to EN 60947-2
yes conforming to IEC 60898-1
yes conforming to IEC 60947-2
Trip Unit Technologythermal-magnetic
Utilisation Categorycategory A conforming to EN 60947-2
category A conforming to IEC 60947-2
COMPLEMENTARY
Communication Network Type12...133 V AC 50/60 Hz
220...240 V AC 50/60 Hz
380...415 V AC 50/60 Hz
400 V AC 50/60 Hz
440 V AC 50/60 Hz
72...125 V DC
Current Transformer TypeN
Interlocked Device10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Product NameActi9 iC60
[Ics] Rated Service Breaking Capacity10 kA 100 % conforming to EN 60947-2 - 72...125 V DC
10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC
25 kA 100 % conforming to EN 60947-2 - 440 V AC 50/60 Hz
25 kA 100 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz
[In] Rated Current4 A
9 Mm Pitches4
Colourwhite
Comb Busbar And Distribution Block Compatibilitytop or bottom: YES
Compatibility CodeiC60
Connections - Terminalssingle terminal (top or bottom) 1-16 mm² flexible
single terminal (top or bottom) 1-25 mm² rigid
Contact Position Indicatoryes
Depth78.5 mm
Device Applicationdistribution
Earth-leakage Protectionseparate block
Electrical Durability10000 cycles
Height85 mm
Limitation Class3 conforming to EN 60898-1
3 conforming to IEC 60898-1
Local Signallingtrip indicator
Magnetic Tripping Limit4 x In +/- 20 %
Market Segmentsmall commercial
Mechanical Durability20000 cycles
Mounting Modefixed
Net Weight0.25 kg
Network Frequency50/60 Hz
Tightening Torque2-2 N.m top or bottom
Width36 mm
Wire Stripping Length14 mm for top or bottom connection
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
[Ui] Rated Insulation Voltage500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
ENVIRONMENT
Ambient Air Temperature For Operation-35-70 °C
Ambient Air Temperature For Storage-40-85 °C
IP Degree Of ProtectionIP20 conforming to EN 60529
IP20 conforming to IEC 60529
Operating Altitude0...2000 m
Overvoltage CategoryIV
Pollution Degree3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Relative Humidity95-95 % at 55-55 °C
StandardsEN 60898-1
EN 60947-2
IEC 60898-1
IEC 60947-2
Tropicalisation2 conforming to IEC 60068-1
OTHER
Poles Description2P
[Us] Rated Supply VoltageiC60
Write Your Own Review
You're reviewing:Miniature Circuit-breaker, Acti9 IC60N, 2P, 4 A, B Curve, 6000 A (IEC 60898-1), 50 KA (IEC 60947-2)
Your Rating