A9C70134 - ARA Auto Recloser Aux for IC60 3P-4P - 4 Prog

Schneider
SKU
SE_A9C70134
Model
A9C70134
SGD $544.41 All prices inclusive of GST

Short description of A9C70134

A9C70134. ARA AUTOMATIC RECLOSER AUXILIARY FOR IC6
Country of Origin
Spain
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 13 To 15 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
ARA auto recloser aux for iC60 3P
- 4P
-  4 Prog.
Label :  Acti 9 iC60
-  range of product :  iC60
-  range :  Acti 9
-  product or component type :  automatic recloser auxiliary
-  device short name :  ARA iC60
-  signal contacts composition :  2 OF volt
- free contacts
-  signalling circuit voltage :  N/A, N/A
-  Range Presentation :  With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
-  VisiSafe  :  for safe operation and maintenance work on circuits.
-  Class-2 insulation  :  continuous safety for operators and unqualified personnel.
-  VisiTrip  :  detects faulty Miniature Circuit
- Breaker outgoers quickly and reduces intervention time.
-  Add-on fully immune earth leakage protection devices  :  better continuity of service, especially in polluted environments and networks.
-  Nominal current :  1 to 63 A
-  Large choice of breaking capacities up to 100 kA and tripping curves :  B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
-  Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
-  Suitable for isolation in accordance with industrial standard IEC 60947
-  Operating voltage :  up to 440 V AC, insulation voltage :  500 V
-  Optional add-on earth leakage modules :  iC60 Vigi,
-  Optional auxiliaries :  indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
-  For more information click here
-  Range Benefits : 
-  The new reference in final distribution,
-  Absolute safety of circuit protection with VisiSafe,
-  Greater continuity of service with VisiTrip,
-  Simple to choose with meaningful part numbers,
-  Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
-  Environmentally friendly with 100% recyclable & recoverable materials.
-  Range Application Presentation :  Low-voltage final distribution
-  Protection of electrical circuits in all industrial and commercial buildings,
-  All applications, especially in polluted environments and networks,
-  Motor circuit protection,
-  DC current circuit protection.

This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS
Analogue Input Number230 V AC 50/60 Hz
Control Typeinhibition of automatism maintained 230 V AC 50/60 Hz
ultimate reclosing impulse 230 V AC 50/60 Hz
Product Or Component Typeautomatic recloser auxiliary
Range Of ProductiC60
[Ie] Rated Operational Currentinhibition of automatism maintained 230 V AC 50/60 Hz
ultimate reclosing impulse 230 V AC 50/60 Hz
Device Short NameARA iC60
EAN133606480097997
Mounting SupportDIN rail
RangeActi 9
Range Compatibility Acti9 iC60
Range NameActi 9 iC60
Signal Contacts Composition2 OF volt-free contacts
Signalling Circuit Voltage 230 V 1 A AC
24 V 10 mA AC/DC
COMPLEMENTARY
9 Mm Pitches7
Colourwhite
Comb Busbar And Distribution Block CompatibilityNO
Compatibility CodeARA iC60
Connections - Terminalsinput: tunnel type terminals 1 cable(s) 0.5-10 mm² rigid without cable end
input: tunnel type terminals 1 cable(s) 0.5-4 mm² flexible with cable end
input: tunnel type terminals 1 cable(s) 0.5-6 mm² flexible without cable end
input: tunnel type terminals 2 cable(s) 0.5-1.5 mm² flexible without cable end
input: tunnel type terminals 2 cable(s) 0.5-2.5 mm² flexible with cable end
input: tunnel type terminals 2 cable(s) 0.5-2.5 mm² rigid without cable end
output: tunnel type terminals 1 cable(s) 0.5-1.5 mm² flexible with cable end
output: tunnel type terminals 1 cable(s) 0.5-2.5 mm² flexible without cable end
output: tunnel type terminals 1 cable(s) 0.5-2.5 mm² rigid without cable end
output: tunnel type terminals 2 cable(s) 0.5-1.5 mm² flexible with cable end
output: tunnel type terminals 2 cable(s) 0.5-1.5 mm² flexible without cable end
output: tunnel type terminals 2 cable(s) 0.5-1.5 mm² rigid without cable end
power supply: tunnel type terminals 1 cable(s) 0.5-10 mm² rigid without cable end
power supply: tunnel type terminals 1 cable(s) 0.5-4 mm² flexible with cable end
power supply: tunnel type terminals 2 cable(s) 0.5-2.5 mm² flexible with cable end
power supply: tunnel type terminals 2 cable(s) 0.5-2.5 mm² rigid without cable end
Depth75.5 mm
Electrical Durability5000 cycles
Height93 mm
Impulse Duration>= 200 ms control circuit
Input Current5 mA
Local Signallingfixed red LED: automatic recloser locked
flashing green LED: normal operation
flashing orange LED: not operational
flashing red LED: reclosing cycle in progress
Locking Options Descriptionpadlocking in OFF position
Market Segmentresidential
small commercial
Mounting Modeclip-on
Net Weight470 g
Power Consumption In W2 W
Product Compatibility3P iC60
4P iC60
Provision For Padlockingpadlockable
Response Time< 500 ms
Tightening Torqueinput: 1-1 N.m
output: 0.7-0.7 N.m
power supply: 1-1 N.m
Value Of Settingprogram 1: 1 reclosing attemp, short cycle <10 s before reclosing /6 min check time
program 2: 3 reclosing attemps, short cycle <1 min before reclosing /6 min check time
program 2: 3 reclosing attemps, short cycle <10 s before reclosing /2 min check time
program 2: 3 reclosing attemps, short cycle <3 min before reclosing /6 min check time
program 3: 5 reclosing attemps, long fixed cycle <1 min before reclosing /6 min check time
program 3: 5 reclosing attemps, long fixed cycle <10 s before reclosing /2 min check time
program 3: 5 reclosing attemps, long fixed cycle <3 min before reclosing /6 min check time
program 4: 5 reclosing attemps, long progressive cycle <1 min before reclosing /6 min check time
program 4: 5 reclosing attemps, long progressive cycle <10 s before reclosing /2 min check time
program 4: 5 reclosing attemps, long progressive cycle <3 min before reclosing /8 min check time
program 4: 5 reclosing attemps, long progressive cycle <4 min before reclosing /10 min check time
program 4: 5 reclosing attemps, long progressive cycle <5 min before reclosing /12 min check time
Width63 mm
Wire Stripping Lengthinput: 10 mm for bottom connection
output: 8 mm for top connection
power supply: 10 mm for bottom connection
[Uimp] Rated Impulse Withstand Voltage6 kV
[Ui] Rated Insulation Voltage400 V
ENVIRONMENT
Ambient Air Temperature For Operation-25-60 °C
Ambient Air Temperature For Storage-40-70 °C
IP Degree Of ProtectionIP20 conforming to IEC 60529
Overvoltage CategoryII
Pollution Degree3 conforming to IEC 60947
Relative Humidity93-93 % at 40-40 °C
Tropicalisation2
OTHER
Poles Descriptionautomatic recloser auxiliary
[Us] Rated Supply Voltage230 V AC 50/60 Hz