A9C70134 - ARA Auto Recloser Aux for IC60 3P-4P - 4 Prog
Schneider
SKU
SE_A9C70134
Model
A9C70134
SGD $544.41 All prices inclusive of GST
Short description of A9C70134
A9C70134. ARA AUTOMATIC RECLOSER AUXILIARY FOR IC6
Country of Origin
Spain
ARA auto recloser aux for iC60 3P
- 4P
-  4 Prog.
Label :  Acti 9 iC60
-  range of product :  iC60
-  range :  Acti 9
-  product or component type :  automatic recloser auxiliary
-  device short name :  ARA iC60
-  signal contacts composition :  2 OF volt
- free contacts
-  signalling circuit voltage :  N/A, N/A
-  Range Presentation :  With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
-  VisiSafe  :  for safe operation and maintenance work on circuits.
-  Class-2 insulation  :  continuous safety for operators and unqualified personnel.
-  VisiTrip  :  detects faulty Miniature Circuit
- Breaker outgoers quickly and reduces intervention time.
-  Add-on fully immune earth leakage protection devices  :  better continuity of service, especially in polluted environments and networks.
-  Nominal current :  1 to 63 A
-  Large choice of breaking capacities up to 100 kA and tripping curves :  B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
-  Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
-  Suitable for isolation in accordance with industrial standard IEC 60947
-  Operating voltage :  up to 440 V AC, insulation voltage :  500 V
-  Optional add-on earth leakage modules :  iC60 Vigi,
-  Optional auxiliaries :  indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
-  For more information click here
-  Range Benefits : 
-  The new reference in final distribution,
-  Absolute safety of circuit protection with VisiSafe,
-  Greater continuity of service with VisiTrip,
-  Simple to choose with meaningful part numbers,
-  Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
-  Environmentally friendly with 100% recyclable & recoverable materials.
-  Range Application Presentation :  Low-voltage final distribution
-  Protection of electrical circuits in all industrial and commercial buildings,
-  All applications, especially in polluted environments and networks,
-  Motor circuit protection,
-  DC current circuit protection.
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
- 4P
-  4 Prog.
Label :  Acti 9 iC60
-  range of product :  iC60
-  range :  Acti 9
-  product or component type :  automatic recloser auxiliary
-  device short name :  ARA iC60
-  signal contacts composition :  2 OF volt
- free contacts
-  signalling circuit voltage :  N/A, N/A
-  Range Presentation :  With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
-  VisiSafe  :  for safe operation and maintenance work on circuits.
-  Class-2 insulation  :  continuous safety for operators and unqualified personnel.
-  VisiTrip  :  detects faulty Miniature Circuit
- Breaker outgoers quickly and reduces intervention time.
-  Add-on fully immune earth leakage protection devices  :  better continuity of service, especially in polluted environments and networks.
-  Nominal current :  1 to 63 A
-  Large choice of breaking capacities up to 100 kA and tripping curves :  B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
-  Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
-  Suitable for isolation in accordance with industrial standard IEC 60947
-  Operating voltage :  up to 440 V AC, insulation voltage :  500 V
-  Optional add-on earth leakage modules :  iC60 Vigi,
-  Optional auxiliaries :  indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
-  For more information click here
-  Range Benefits : 
-  The new reference in final distribution,
-  Absolute safety of circuit protection with VisiSafe,
-  Greater continuity of service with VisiTrip,
-  Simple to choose with meaningful part numbers,
-  Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
-  Environmentally friendly with 100% recyclable & recoverable materials.
-  Range Application Presentation :  Low-voltage final distribution
-  Protection of electrical circuits in all industrial and commercial buildings,
-  All applications, especially in polluted environments and networks,
-  Motor circuit protection,
-  DC current circuit protection.
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 230 V AC 50/60 Hz |
Control Type | inhibition of automatism maintained 230 V AC 50/60 Hz ultimate reclosing impulse 230 V AC 50/60 Hz |
Product Or Component Type | automatic recloser auxiliary |
Range Of Product | iC60 |
[Ie] Rated Operational Current | inhibition of automatism maintained 230 V AC 50/60 Hz ultimate reclosing impulse 230 V AC 50/60 Hz |
Device Short Name | ARA iC60 |
EAN13 | 3606480097997 |
Mounting Support | DIN rail |
Range | Acti 9 |
Range Compatibility | Acti9 iC60 |
Range Name | Acti 9 iC60 |
Signal Contacts Composition | 2 OF volt-free contacts |
Signalling Circuit Voltage | 230 V 1 A AC 24 V 10 mA AC/DC |
COMPLEMENTARY | |
9 Mm Pitches | 7 |
Colour | white |
Comb Busbar And Distribution Block Compatibility | NO |
Compatibility Code | ARA iC60 |
Connections - Terminals | input: tunnel type terminals 1 cable(s) 0.5-10 mm² rigid without cable end input: tunnel type terminals 1 cable(s) 0.5-4 mm² flexible with cable end input: tunnel type terminals 1 cable(s) 0.5-6 mm² flexible without cable end input: tunnel type terminals 2 cable(s) 0.5-1.5 mm² flexible without cable end input: tunnel type terminals 2 cable(s) 0.5-2.5 mm² flexible with cable end input: tunnel type terminals 2 cable(s) 0.5-2.5 mm² rigid without cable end output: tunnel type terminals 1 cable(s) 0.5-1.5 mm² flexible with cable end output: tunnel type terminals 1 cable(s) 0.5-2.5 mm² flexible without cable end output: tunnel type terminals 1 cable(s) 0.5-2.5 mm² rigid without cable end output: tunnel type terminals 2 cable(s) 0.5-1.5 mm² flexible with cable end output: tunnel type terminals 2 cable(s) 0.5-1.5 mm² flexible without cable end output: tunnel type terminals 2 cable(s) 0.5-1.5 mm² rigid without cable end power supply: tunnel type terminals 1 cable(s) 0.5-10 mm² rigid without cable end power supply: tunnel type terminals 1 cable(s) 0.5-4 mm² flexible with cable end power supply: tunnel type terminals 2 cable(s) 0.5-2.5 mm² flexible with cable end power supply: tunnel type terminals 2 cable(s) 0.5-2.5 mm² rigid without cable end |
Depth | 75.5 mm |
Electrical Durability | 5000 cycles |
Height | 93 mm |
Impulse Duration | >= 200 ms control circuit |
Input Current | 5 mA |
Local Signalling | fixed red LED: automatic recloser locked flashing green LED: normal operation flashing orange LED: not operational flashing red LED: reclosing cycle in progress |
Locking Options Description | padlocking in OFF position |
Market Segment | residential small commercial |
Mounting Mode | clip-on |
Net Weight | 470 g |
Power Consumption In W | 2 W |
Product Compatibility | 3P iC60 4P iC60 |
Provision For Padlocking | padlockable |
Response Time | < 500 ms |
Tightening Torque | input: 1-1 N.m output: 0.7-0.7 N.m power supply: 1-1 N.m |
Value Of Setting | program 1: 1 reclosing attemp, short cycle <10 s before reclosing /6 min check time program 2: 3 reclosing attemps, short cycle <1 min before reclosing /6 min check time program 2: 3 reclosing attemps, short cycle <10 s before reclosing /2 min check time program 2: 3 reclosing attemps, short cycle <3 min before reclosing /6 min check time program 3: 5 reclosing attemps, long fixed cycle <1 min before reclosing /6 min check time program 3: 5 reclosing attemps, long fixed cycle <10 s before reclosing /2 min check time program 3: 5 reclosing attemps, long fixed cycle <3 min before reclosing /6 min check time program 4: 5 reclosing attemps, long progressive cycle <1 min before reclosing /6 min check time program 4: 5 reclosing attemps, long progressive cycle <10 s before reclosing /2 min check time program 4: 5 reclosing attemps, long progressive cycle <3 min before reclosing /8 min check time program 4: 5 reclosing attemps, long progressive cycle <4 min before reclosing /10 min check time program 4: 5 reclosing attemps, long progressive cycle <5 min before reclosing /12 min check time |
Width | 63 mm |
Wire Stripping Length | input: 10 mm for bottom connection output: 8 mm for top connection power supply: 10 mm for bottom connection |
[Uimp] Rated Impulse Withstand Voltage | 6 kV |
[Ui] Rated Insulation Voltage | 400 V |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-60 °C |
Ambient Air Temperature For Storage | -40-70 °C |
IP Degree Of Protection | IP20 conforming to IEC 60529 |
Overvoltage Category | II |
Pollution Degree | 3 conforming to IEC 60947 |
Relative Humidity | 93-93 % at 40-40 °C |
Tropicalisation | 2 |
OTHER | |
Poles Description | automatic recloser auxiliary |
[Us] Rated Supply Voltage | 230 V AC 50/60 Hz |