A9A26969 Voltage Release - IMNx - Tripping Unit- 220..240VAC
Schneider
SKU
SE_A9A26969
Model
A9A26969
SGD $202.99 All prices inclusive of GST
Short description of A9A26969
A9A26969.
This Acti9 iMNx electrical auxiliary is an undervoltage release independent of the supply voltage. It is dedicated to Acti9 iC60, iID, iDPN Vigi, iSW-NA and iC60, iID double terminals. The width in 9mm pitches is 2. It trips the associated device by opening of the control circuit. A drop in the supply voltage does not trip the associated device. There is a red mechanical indicator on the front face of the product to indicate the tripped position of the associated device. The Ue rated operational voltage is 220VAC to 240VAC. The operating frequency is 50Hz or 60Hz. The operating temperature is -35°C to + 70°C. The storage temperature is -40°C to + 85°C. This product complies with IEC/EN 60947-5-1 standards.
Country of Origin
Belgium
voltage release
-  iMNx
-  tripping unit
-  220..240 VAC.
Label :  Acti 9 iC60
-  range :  Acti 9
-  [Uc] control circuit voltage :  220...240 V AC 50/60 Hz
-  product or component type :  undervoltage release
-  control type :  with external feeding
-  range of product :  iSW
- NA,iC60,iDPN Vigi,iID
-  9 mm pitches :  2
-  device short name :  iMNx
-  product compatibility :  iC60,ARA,RCA,double terminal,iDPN Vigi,iSW
- NA,single terminal,iID
-  Range Presentation :  With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
-  VisiSafe  :  for safe operation and maintenance work on circuits.
-  Class-2 insulation  :  continuous safety for operators and unqualified personnel.
-  VisiTrip  :  detects faulty Miniature Circuit
- Breaker outgoers quickly and reduces intervention time.
-  Add-on fully immune earth leakage protection devices  :  better continuity of service, especially in polluted environments and networks.
-  Nominal current :  1 to 63 A
-  Large choice of breaking capacities up to 100 kA and tripping curves :  B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
-  Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
-  Suitable for isolation in accordance with industrial standard IEC 60947
-  Operating voltage :  up to 440 V AC, insulation voltage :  500 V
-  Optional add-on earth leakage modules :  iC60 Vigi,
-  Optional auxiliaries :  indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
-  For more information click here
-  Range Benefits : 
-  The new reference in final distribution,
-  Absolute safety of circuit protection with VisiSafe,
-  Greater continuity of service with VisiTrip,
-  Simple to choose with meaningful part numbers,
-  Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
-  Environmentally friendly with 100% recyclable & recoverable materials.
-  Range Application Presentation :  Low-voltage final distribution
-  Protection of electrical circuits in all industrial and commercial buildings,
-  All applications, especially in polluted environments and networks,
-  Motor circuit protection,
-  DC current circuit protection.
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  iMNx
-  tripping unit
-  220..240 VAC.
Label :  Acti 9 iC60
-  range :  Acti 9
-  [Uc] control circuit voltage :  220...240 V AC 50/60 Hz
-  product or component type :  undervoltage release
-  control type :  with external feeding
-  range of product :  iSW
- NA,iC60,iDPN Vigi,iID
-  9 mm pitches :  2
-  device short name :  iMNx
-  product compatibility :  iC60,ARA,RCA,double terminal,iDPN Vigi,iSW
- NA,single terminal,iID
-  Range Presentation :  With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
-  VisiSafe  :  for safe operation and maintenance work on circuits.
-  Class-2 insulation  :  continuous safety for operators and unqualified personnel.
-  VisiTrip  :  detects faulty Miniature Circuit
- Breaker outgoers quickly and reduces intervention time.
-  Add-on fully immune earth leakage protection devices  :  better continuity of service, especially in polluted environments and networks.
-  Nominal current :  1 to 63 A
-  Large choice of breaking capacities up to 100 kA and tripping curves :  B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
-  Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
-  Suitable for isolation in accordance with industrial standard IEC 60947
-  Operating voltage :  up to 440 V AC, insulation voltage :  500 V
-  Optional add-on earth leakage modules :  iC60 Vigi,
-  Optional auxiliaries :  indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
-  For more information click here
-  Range Benefits : 
-  The new reference in final distribution,
-  Absolute safety of circuit protection with VisiSafe,
-  Greater continuity of service with VisiTrip,
-  Simple to choose with meaningful part numbers,
-  Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
-  Environmentally friendly with 100% recyclable & recoverable materials.
-  Range Application Presentation :  Low-voltage final distribution
-  Protection of electrical circuits in all industrial and commercial buildings,
-  All applications, especially in polluted environments and networks,
-  Motor circuit protection,
-  DC current circuit protection.
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Control Type | with external feeding |
Product Or Component Type | undervoltage release |
Range Of Product | iC60 iDPN Vigi iID iSW-NA |
[Ie] Rated Operational Current | with external feeding |
[Uc] Control Circuit Voltage | 220...240 V AC 50/60 Hz |
Device Short Name | iMNx |
EAN13 | 3606480088025 |
Mounting Support | DIN rail |
Range | Acti 9 |
Range Compatibility | Acti 9 ARA Acti 9 iC40 Acti 9 iDPN (China version) Acti 9 RCA Acti9 iC60 double terminals miniature circuit breaker Acti9 iC65 Acti9 iDPN Vigi Acti9 iID Acti9 iSW-NA |
Range Name | Acti 9 iC60 |
COMPLEMENTARY | |
9 Mm Pitches | 2 |
Colour | white |
Compatibility Code | iMNx |
Connections - Terminals | clamp terminal - 1 cable(s) 11-11 mm² - rigid clamp terminal - 1 cable(s) 9-9 mm² - flexible clamp terminal - 2 cable(s) 2.1-2.1 mm² - flexible with cable end clamp terminal - 2 cable(s) 2.1-2.1 mm² - rigid |
Local Signalling | action indicator |
Market Segment | residential small commercial |
Mounting Mode | clip-on |
Product Compatibility | ARA double terminal iC60 iDPN Vigi iID iSW-NA RCA single terminal |
Tightening Torque | 1-1 N.m |
Width | 18 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-50 °C |
Ambient Air Temperature For Storage | -40-85 °C |
Relative Humidity | 95-95 % at 55-55 °C |
Standards | EN/IEC 60947-5-1 |
Tropicalisation | 2 conforming to EN/IEC 60947-5-1 |
OTHER | |
Poles Description | undervoltage release |
[Us] Rated Supply Voltage | iC60 iDPN Vigi iID iSW-NA |
Write Your Own Review