Loading...

IOF+SD24 Open/Close & Fault Indicating Auxiliary Contact with Ti24 Top Connector

Schneider
SKU
SE_A9A26897
Model
A9A26897

Obsolete

All prices inclusive of GST

Short description of A9A26897

ACTI9 IOF SD 24V DC WITH TI24 PLC INTERF
Obsolete
*All information are subjected to changes without prior notice.
iOF+SD24 open/close & fault indicating auxiliary contact with Ti24 top connector.
Label :  Acti 9 iC60
-  range :  Acti 9
-  range of product :  ARA,iID,RCA,iC60,iSW
- NA,iDPN Vigi
-  9 mm pitches :  1
-  product or component type :  OC and fault contact with PLC interface
-  device short name :  iOF+SD 24
-  signal contacts composition :  1 NO + 1 NC
-  [In] rated current : 
-  Range Presentation :  With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
-  VisiSafe  :  for safe operation and maintenance work on circuits.
-  Class-2 insulation  :  continuous safety for operators and unqualified personnel.
-  VisiTrip  :  detects faulty Miniature Circuit
- Breaker outgoers quickly and reduces intervention time.
-  Add-on fully immune earth leakage protection devices  :  better continuity of service, especially in polluted environments and networks.
-  Nominal current :  1 to 63 A
-  Large choice of breaking capacities up to 100 kA and tripping curves :  B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,
-  Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs),
-  Suitable for isolation in accordance with industrial standard IEC 60947
-  Operating voltage :  up to 440 V AC, insulation voltage :  500 V
-  Optional add-on earth leakage modules :  iC60 Vigi,
-  Optional auxiliaries :  indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
-  For more information click here
-  Range Benefits : 
-  The new reference in final distribution,
-  Absolute safety of circuit protection with VisiSafe,
-  Greater continuity of service with VisiTrip,
-  Simple to choose with meaningful part numbers,
-  Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),
-  Environmentally friendly with 100% recyclable & recoverable materials.
-  Range Application Presentation :  Low-voltage final distribution
-  Protection of electrical circuits in all industrial and commercial buildings,
-  All applications, especially in polluted environments and networks,
-  Motor circuit protection,
-  DC current circuit protection.
MAIN SPECIFICATIONS
Contacts Type And Composition2-100 mA at 24 V DC +/- 20 %
Product Or Component TypeOC and fault contact with PLC interface
Range Of ProductARA
iC60
iDPN Vigi
iID
iSW-NA
RCA
Device Short NameiOF+SD 24
EAN133606480461613
Mounting SupportDIN rail
RangeActi 9
Range Compatibility Acti 9 ARA
Acti 9 iC40
Acti 9 iDPN (China version)
Acti 9 RCA
Acti9 iC60
Acti9 iC60 RCBO
Acti9 iC65
Acti9 iDPN Vigi
Acti9 iID
Acti9 iSW-NA
connectors Ti24
Range NameActi 9 iC60
Signal Contacts Composition1 NO + 1 NC
COMPLEMENTARY
[In] Rated Current2-100 mA at 24 V DC +/- 20 %
9 Mm Pitches1
Colourwhite
Compatibility CodeiOF+SD 24
Connections - Terminalsspring-loaded terminal Ti24 (top) 2 cable(s) 0.5-1.5 mm² - flexible
spring-loaded terminal Ti24 (top) 2 cable(s) 0.5-1.5 mm² - rigid
Depth73.5 mm
Electrical Durability20000 cycles conforming to IEC 60947-5-4
Height88 mm
Local Signallingmechanical indicator
Market Segmentresidential
small commercial
Mounting Modeclip-on
Net Weight25 g
Product CompatibilityARA
double terminal
iC60
iDPN Vigi
iID
iSW-NA
RCA
single terminal
Ti24
Width9 mm
Wire Stripping Length10 mm
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60664-1
[Ui] Rated Insulation Voltage500 V conforming to IEC 60664-1
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-40-85 °C
Overvoltage CategoryIII
Pollution Degree2 conforming to IEC 60664-1
Quality LabelsCE
Relative Humidity93-93 % at 40-40 °C
StandardsIEC 60947-5-1
IEC 60947-5-4
Tropicalisation2 conforming to IEC 60947-5-1
OTHER
Poles DescriptionOC and fault contact with PLC interface
[Us] Rated Supply VoltageARA
iC60
iDPN Vigi
iID
iSW-NA
RCA