18868 - Miniature Circuit-breaker, Acti9 NG125LMA, 2P, 4 A, MA Curve, 50 KA (IEC 60947-2).
Schneider
SKU
SE_18868
Model
18868
SGD $350.42 All prices inclusive of GST
Short description of 18868
18868. Motor starter protection up to 80 A
Country of Origin
France
range of product : NG125
-  range : Acti 9
-  product name : Acti 9 NG125LMA
-  product or component type : Miniature circuit-breaker
-  device short name : NG125LMA
-  device application : Motor
-  poles description : 2P
-  number of protected poles : 2
-  [In] rated current : 4 A at 40 °C
-  network type : AC
-  trip unit technology : Magnetic
-  curve code : MA
-  breaking capacity : 100 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-240 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-250 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-215 kA Icu at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
-  utilisation category : Category A conforming to IEC 60947-2
-  suitability for isolation : Yes conforming to IEC 60947-2
-  range : Acti 9
-  product name : Acti 9 NG125LMA
-  product or component type : Miniature circuit-breaker
-  device short name : NG125LMA
-  device application : Motor
-  poles description : 2P
-  number of protected poles : 2
-  [In] rated current : 4 A at 40 °C
-  network type : AC
-  trip unit technology : Magnetic
-  curve code : MA
-  breaking capacity : 100 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-240 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-250 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-215 kA Icu at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
-  utilisation category : Category A conforming to IEC 60947-2
-  suitability for isolation : Yes conforming to IEC 60947-2
MAIN SPECIFICATIONS | |
---|---|
Breaking Capacity | 100 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 40 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
Breaking Capacity Code | L |
Contacts Type And Composition | 4 A at 40 °C |
Control Type | manual tripping test toggle |
Product Or Component Type | miniature circuit-breaker |
Range Of Product | NG125 |
[Ie] Rated Operational Current | manual tripping test toggle |
[Ue] Rated Operational Voltage | 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz 500 V AC 50/60 Hz |
Curve Code | MA |
Device Short Name | NG125LMA |
Mounting Support | 35 mm symmetrical DIN rail |
Network Type | AC |
Number Of Protected Poles | 2 |
Range | Acti 9 |
Range Name | Acti 9 NG125 L-MA |
Suitability For Isolation | yes conforming to IEC 60947-2 |
Trip Unit Technology | magnetic |
Utilisation Category | category A conforming to IEC 60947-2 |
COMPLEMENTARY | |
Communication Network Type | 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz 500 V AC 50/60 Hz |
Current Transformer Type | L |
Interlocked Device | 100 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 40 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
Product Name | Acti9 NG125LMA |
[Ics] Rated Service Breaking Capacity | 11.25 kA 75 % conforming to EN/IEC 60947-2 - 500 V AC 50/60 Hz 30 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 37.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 75 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz |
[In] Rated Current | 4 A at 40 °C |
9 Mm Pitches | 6 |
Comb Busbar And Distribution Block Compatibility | yes |
Compatibility Code | NG125 |
Connections - Terminals | tunnel type terminals1.5-50 mm² rigid tunnel type terminals1-35 mm² flexible |
Contact Position Indicator | yes |
Depth | 81 mm |
Device Application | motor |
Earth-leakage Protection | separate block |
Electrical Durability | 10000 cycles |
Height | 103 mm |
Local Signalling | ON/OFF indication trip indicator |
Locking Options Description | integrated padlocking |
Magnetic Tripping Limit | 12 x In |
Market Segment | small buildings small commercial |
Mechanical Durability | 20000 cycles |
Mounting Mode | clip-on |
Net Weight | 0.48 kg |
Network Frequency | 50/60 Hz |
Provision For Padlocking | padlockable |
Tightening Torque | 3.5-3.5 N.m |
Width | 54 mm |
Wire Stripping Length | 20 mm |
[Uimp] Rated Impulse Withstand Voltage | 8 kV conforming to EN/IEC 60947-2 |
[Ui] Rated Insulation Voltage | 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -30-70 °C |
Ambient Air Temperature For Storage | -40-70 °C |
IK Degree Of Protection | IK05 conforming to EN/IEC 62262 |
IP Degree Of Protection | IP20 conforming to IEC 60529 |
Operating Altitude | 2000 m |
Overvoltage Category | IV |
Pollution Degree | 3 conforming to IEC 60947-2 |
Relative Humidity | 95-95 % at 55-55 °C |
Standards | EN/IEC 60947-2 |
Tropicalisation | 2 conforming to IEC 60068-1 |
OTHER | |
Poles Description | 2P |
[Us] Rated Supply Voltage | NG125 |
Write Your Own Review