18868 - Miniature Circuit-breaker, Acti9 NG125LMA, 2P, 4 A, MA Curve, 50 KA (IEC 60947-2).

Schneider
SKU
SE_18868
Model
18868
SGD $350.42 All prices inclusive of GST

Short description of 18868

18868. Motor starter protection up to 80 A
Country of Origin
France
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 11 To 13 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
range of product : NG125
-  range : Acti 9
-  product name : Acti 9 NG125LMA
-  product or component type : Miniature circuit-breaker
-  device short name : NG125LMA
-  device application : Motor
-  poles description : 2P
-  number of protected poles : 2
-  [In] rated current : 4 A at 40 °C
-  network type : AC
-  trip unit technology : Magnetic
-  curve code : MA
-  breaking capacity : 100 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-240 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-250 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-215 kA Icu at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
-  utilisation category : Category A conforming to IEC 60947-2
-  suitability for isolation : Yes conforming to IEC 60947-2
MAIN SPECIFICATIONS
Breaking Capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
15 kA Icu at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
40 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking Capacity CodeL
Contacts Type And Composition4 A at 40 °C
Control Typemanual tripping test
toggle
Product Or Component Typeminiature circuit-breaker
Range Of ProductNG125
[Ie] Rated Operational Currentmanual tripping test
toggle
[Ue] Rated Operational Voltage220...240 V AC 50/60 Hz
380...415 V AC 50/60 Hz
440 V AC 50/60 Hz
500 V AC 50/60 Hz
Curve CodeMA
Device Short NameNG125LMA
Mounting Support35 mm symmetrical DIN rail
Network TypeAC
Number Of Protected Poles2
RangeActi 9
Range NameActi 9 NG125 L-MA
Suitability For Isolationyes conforming to IEC 60947-2
Trip Unit Technologymagnetic
Utilisation Categorycategory A conforming to IEC 60947-2
COMPLEMENTARY
Communication Network Type220...240 V AC 50/60 Hz
380...415 V AC 50/60 Hz
440 V AC 50/60 Hz
500 V AC 50/60 Hz
Current Transformer TypeL
Interlocked Device100 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
15 kA Icu at 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
40 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Product NameActi9 NG125LMA
[Ics] Rated Service Breaking Capacity11.25 kA 75 % conforming to EN/IEC 60947-2 - 500 V AC 50/60 Hz
30 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
37.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz
75 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz
[In] Rated Current4 A at 40 °C
9 Mm Pitches6
Comb Busbar And Distribution Block Compatibilityyes
Compatibility CodeNG125
Connections - Terminalstunnel type terminals1.5-50 mm² rigid
tunnel type terminals1-35 mm² flexible
Contact Position Indicatoryes
Depth81 mm
Device Applicationmotor
Earth-leakage Protectionseparate block
Electrical Durability10000 cycles
Height103 mm
Local SignallingON/OFF indication
trip indicator
Locking Options Descriptionintegrated padlocking
Magnetic Tripping Limit12 x In
Market Segmentsmall buildings
small commercial
Mechanical Durability20000 cycles
Mounting Modeclip-on
Net Weight0.48 kg
Network Frequency50/60 Hz
Provision For Padlockingpadlockable
Tightening Torque3.5-3.5 N.m
Width54 mm
Wire Stripping Length20 mm
[Uimp] Rated Impulse Withstand Voltage8 kV conforming to EN/IEC 60947-2
[Ui] Rated Insulation Voltage690 V AC 50/60 Hz conforming to EN/IEC 60947-2
ENVIRONMENT
Ambient Air Temperature For Operation-30-70 °C
Ambient Air Temperature For Storage-40-70 °C
IK Degree Of ProtectionIK05 conforming to EN/IEC 62262
IP Degree Of ProtectionIP20 conforming to IEC 60529
Operating Altitude2000 m
Overvoltage CategoryIV
Pollution Degree3 conforming to IEC 60947-2
Relative Humidity95-95 % at 55-55 °C
StandardsEN/IEC 60947-2
Tropicalisation2 conforming to IEC 60068-1
OTHER
Poles Description2P
[Us] Rated Supply VoltageNG125
Write Your Own Review
You're reviewing:18868 - Miniature Circuit-breaker, Acti9 NG125LMA, 2P, 4 A, MA Curve, 50 KA (IEC 60947-2).